Skip to content

Harmony 880 and 885: USB

A Harmony 880 or 885 speaks the same command protocol over its USB cable as the Harmony 525, the Harmony One and the Harmony 600, 650 and 700: a host asks for its version, reads its flash by address and writes it back. That is how other people read its configurations and its firmware off their remotes. This page says how the remote identifies itself and what its version block holds; the protocol itself is the USB protocol.

A Harmony 885 has answered on a cable, and everything below that the images predicted, it reported; the rest is read in the firmware images or stated by Logitech's client, as each footnote says. This said no remote of this architecture had been on a cable until one was.6

Identity

value source
vendor and product id 0x046D:0xC110, Logitech's Espresso platform 1
transport the HID command reports, the first of the three transports Logitech's classic client knows: it builds the same channel for Espresso as for the Harmony 525's and the Harmony One's platforms 1
bcdDevice 0x080F on an 880 and 0x0811 on an 885: protocol 8 in the high byte and the skin in plain binary in the low, the older of the two forms 2, and the 885's on a unit8
endpoints one HID interface, interrupt IN on endpoint 1 and OUT on endpoint 2, 64 bytes each way every 1 ms, and a 33 byte report descriptor that declares the input report Absolute, as the Harmony One's does 8
product string Harmony Remote 0-4.4.2 on an 885 8

Read as BCD, the 885's word names the wrong remote: 0x11 is 17 in binary, the Harmony 885, and 11 in BCD, which is a Harmony 655 in Logitech's model list. The 880's 0x0F is 15 under either reading, so the 880 alone could not show the difference. The two forms are told apart by the word's value, the transport.2

This library reads these remotes and writes none of them. It said it opened none until a Harmony 885 was opened unchanged; what it lacked was an address rule for reads, which it has now. Its configuration reader holds a profile for 0xC110, reading from 0x020000,18 and has read a configuration off 885s whole;17 the generated table in the Harmony 885's usb.md states what the code holds. This said the reader still held no profile for 0xC110 until one was added.18

Reading flash

The application checks no address on a read. READ_FLASH parses the address into a 24 bit table pointer and fetches every byte with one table read; only the erase calls an address check. So a read past the part is not refused by the remote, and the bound of 0x200000 is the library's, the program memory space of a PIC18.7

A read comes back in chunks of 62, 30, 14 or 6 data bytes and a last one of 1 to 5: the remote sends a chunk of length 63, 31, 15 or 7, the sequence byte included, the largest that the remaining count fills, or the rest when fewer than six bytes remain. The sequence byte steps by 0x11 from chunk to chunk. The count reaches zero for every one of the 65536 counts, because the byte loop counts down by one and every chunk carries at least one byte, so the odd count hang of the Harmony One has no counterpart here; an odd count on a remote is not measured.105 This page used to quote 63, 31, 15 and 7 as the chunk sizes, which are the lengths with the sequence byte in them.10

Two last bytes are not flash. When a read's last byte is 0x000104 or 0x000105 and it is alone in its chunk, which needs an odd count ending there, the remote does not fetch it:10

  • 0x000104 returns the newest entry of the hardware version log at 0x000140 to 0x000147, the same byte the version block reports as the hardware version, in place of the flash byte there.10
  • 0x000105 takes a measurement: by the registers it uses, which the processor family names a port and the analogue converter, it switches a pin on, averages eight conversions on channel 1, switches the pin off and returns a scaled result. It is the one read that acts on the hardware. The register reading is inferred from the family, and what channel 1 measures is not identified.105

The bootloader does the same at the same two addresses.9 This page said what those return is not checked until the routines were read.10

The 8 KiB below 0x200000 hold devices, not only flash: the firmware reaches what the code that uses them makes its keypad latches, its USB controller and its display controller at 0x1FE040 to 0x1FE0C1, and runs code in a window onto its RAM from 0x1FFE00, so a read there is a bus cycle on a device or on RAM, memory.md; which part sits at each address is not checked against the hardware.95 A read of the display controller's data port would advance the controller's own address, on the controller family its command bytes fit, and a read of the USB controller's data port reads whichever of its registers is selected; both inferred, not checked.5 Above 0x1FFFFF the address goes to the processor unmasked, and a read that starts below 0x200000 and runs past it continues above it. By the PIC18 family that reaches the configuration space up to 0x3FFFFF and the bottom of flash again from 0x400000; inferred from the family and not checked against the part.105

So the safe window for reading a whole region is 0x000000 to 0x1FDFFF, ending no transfer at 0x000104 or 0x000105 with an odd count. Reads of 0x8000 bytes from a 0x8000 boundary and the 64 byte identity read never meet the two.10 The library refuses a read by where it starts and not where it ends, so a read that starts below 0x1FE000 and runs into the device window is not refused by packages/usb; its region check, validateRegionByte in packages/usb/src/protocol.ts, is the evidence.

Writing flash

A write is the transfer every Harmony uses, and the remote never says whether anything was written. An announce with an address and a count, data packets of up to 63 bytes with no reply each, and a done packet the remote answers with F0 30.11 What a host has to know on this platform:11

  • The remote erases nothing before it programs. Each byte goes into whatever the flash holds, so a sector has to be erased first, and over old content a programmed byte can only clear bits.
  • The application skips 0xFF bytes and leaves the old byte there, where the bootloader programs every byte, 0xFF included.119 Over erased flash the two come to the same thing; over unerased flash a write can read back partly right and partly old.
  • The address is checked once per packet, on its first byte, with the floor at 0x010000 and the unlock below it as in the bootloader, and no ceiling. A packet starting just below 0x010000 without the unlock is dropped whole, its bytes above 0x010000 included, and the next one lands where it would have.
  • F0 30 comes back whatever happened: a refused packet, a program that failed and a count never reached all answer the same. Only a read back says what was written.
  • The announced count is never enforced; the transfer is as long as the packets the host sends. The 3150 byte transfer is Logitech's client's choice, and nothing in the remote bounds it.
  • The length nibble decodes as on the other platforms read: 0 to 7 as they are, 0x08 as 15, 0x09 as 31 and 0x0A as 63, and 0x0B to 0x0F left as 11 to 15, the commands.
  • Two addresses are not flash. A one byte packet at 0x000106 sets the unlock and writes nothing, and the unlock then stays set until the remote next starts or goes to sleep; a write with one byte left at 0x000104 appends to the hardware log instead, and in the application programs nothing unless the unlock was set first.
  • A packet that is neither data nor done ends the transfer with no reply.

Erasing flash

One erase takes one address and removes the sector of the part that holds it, memory.md. The application checks the address twice, as the bootloader does: a floor at 0x010000 below which the erase needs the unlock byte, and no ceiling.11 So the running application at 0x010000 is erased with no unlock at all; only the bootloader, below, is guarded.11 That the remote then stops answering until its bootloader takes over at the next start is inferred, not checked.5

F0 D0 does not mean erased. Once the floor passes, the erase runs at once and the reply follows whatever the routine did, a refusal by the unlock test or a part that gave up included. A refused erase gets no reply from the command: the remote calls its error routine and drops the command, so the host waits for a reply that does not come; what the error routine does besides drawing is not read.115 So a writer should erase only whole 64 KiB sectors from 0x020000, and read every erased sector back.11

How a write ends

The escape is handled, by the packet parser before the command switch, which is why the switch holds no case for it: E1 01 clears the command state, and E1 02 and E1 03 restart the remote, which waits 500 ticks of its timer and executes the processor's RESET; none of them replies, and any other sub code does nothing.12 This page said the dispatch's lack of a case meant that, so neither the session end nor the restart is reached from it, until the parser was read.12

Only a restart takes up a new configuration: the check and the sizing of its state variables run at a start and at no other moment, firmware.md.1215

The misc commands. WRITE_MISC takes five bytes whatever its length nibble, serves six selectors and answers each F0 A0; any other selector gets no reply at all.12

selector WRITE_MISC READ_MISC
0x01 writes a state variable: of the four bytes after the selector, the second is the index and the last two the value; an index past the declared variables is refused and still answered the state variable at the low address byte, high byte then low
0x02 moves every lookup to the built in configuration until the next start
0x05 a zero first byte switches every interrupt off; anything else on
0x06 the staged install's status: the first byte must be zero, the second is the status the status, when the address's high byte is zero
0x07 one byte of data memory at the address, with no bound one byte of data memory, with no bound
0x08 recalculates a value from the clock, when a configuration passed its check
any other no reply two zero bytes

Write misc selector 7 reaches the guards of a flash write the application keeps in data memory: the unlock, the staged install's status, the configuration flags, the log's address and the RAM the flash routines run from, memory.md.16

READ_MISC answers C2, the selector and two bytes; a host that takes a narrow state variable from the third byte reads zero, the trap the commands record on the Harmony 525.12 The clock is state variables 0 to 6, at data memory 0x108 to 0x10E, so either READ_MISC selector reads it, memory.md.12

Of the eight step write sequence of the Harmony One and the Harmony 600, 650 and 700, the commands, two steps must not be carried over:12

  • step 2, WRITE_MISC selector 0x0A, does not exist here, and sending it gets no reply at all, so a writer waiting for one hangs until it times out;
  • step 7, status 2, must not be sent: at the restart that follows, the bootloader would erase the application and copy 64 KiB from 0x1D0000 over it, firmware.md.

Step 3, status 0 and its read back, is harmless and worth keeping as a read, since a status other than zero turns the restart into an application install; step 4, selector 2, keeps the remote off the region being rewritten; step 8 is E1 02, with no reply, after which the remote comes back through its bootloader.12 Logitech's classic client never writes the status for a configuration on this platform: after the write it erases the event range the configuration's header names, restarts the remote the same way, and then writes the saved state variables back and sets the clock.13

On an 885 that sequence was performed once and the remote took the configuration up: selector 2 was answered, three sectors of the configuration were erased and rewritten, the status read 0 before and after, E1 02 was sent, and the remote was back on the bus within five seconds holding the written configuration byte for byte, its clock standing on the configuration's stamp plus the seconds since the restart. The status was read with READ_MISC selector 7 at 0x100. An 880 is not checked.145

In the bootloader

The bootloader answers the same protocol, six of the application's commands and the escape, with no 0x70, and it enumerates with the application's own device descriptor, so the ids cannot tell a remote held in its bootloader from a running one; the product string Harmony Bootloader and the version block's software type 3 can, the bootloader.9 This page listed which commands the bootloader dispatches as not checked until the bootloader was read.

The version block

The firmware answers the version request from five constants returned by consecutive RETLW instructions at 0x11C46, in the order field 0, field 4's low nibble, field 5, field 6, field 4's high nibble.3

field application, 880 application, 885 bootloader, 880 and 885 what it is
0 0x44 0x44 0x40 the firmware version, BCD
4, low nibble 0 0 3 the software type: application, or Boot mode
5 0x0F 0x11 0x0F, 0x11 the skin, 15 or 17
6 0x08 0x08 0 the platform, below
4, high nibble 8 8 8 the architecture

Read in the two applications3 and the two bootloaders.4 A Harmony 885 running its application answers 44 21 49 01 80 11 08, the four predicted fields exactly.6 The other three come from the remote itself: the hardware version is the newest entry of the hardware log at 0x000140, and the flash ids are read off the part, with an Atmel 1F:C0 reported as 01:49 by the application and as it is by the bootloader, memory.md.1011

Field 6 names a platform and not an architecture. It is 8 here, 9 on the Harmony 525, and 12 on both the Harmony One and the Harmony 600, 650 and 700, and it is the same in a remote's safe mode image as in its application on those last two, so it reads as the lowest architecture of its platform. That reading is not confirmed, and nothing depends on it.4

In the two bootloaders field 6 is zero, where the applications carry 8. No safe mode image of this architecture is known, so whether one would report zero there too is not checked.45 The mode a remote is in is field 4's low nibble, the version block.

What a configuration file states against it

A configuration file's header names the remote it was built for, and a host compares it with this block before writing, the EZHex wrapper. On this platform the comparison works as written, and two of its fields mean something narrower than their names:

  • FLASH asks whether the application knows the part, not which part is fitted. The configuration files read for this platform all state 0x01:0x49,20 which is what the application reports for either part it knows, memory.md. A unit whose part the application does not know reports FF:FF,11 and the comparison refuses such a block against a file stating 0x01:0x49.20
  • BOARD is stored on each unit: it is the newest entry of the hardware log at 0x000140, which the bootloader writes and a host can append to, so it is not a constant compiled into the firmware. The library's rails confine a flash write to the configuration region, so nothing it sends reaches that log.1011
  • PROTOCOL is the architecture, 8, and field 6 is 8 here as well. So on this platform a reader that took PROTOCOL from field 6 would still compare correctly, and nothing on it would show that mistake.19

The Harmony 885 configuration read matches the block a Harmony 885 reports on all five fields it states. Five Harmony 880 configuration files are refused against the same block on SKIN and BOARD, skin 15 against 17 and board 1.8.0 against 2.1, and on nothing else.19 Whether an 880 configuration would run on an 885 is not checked.5

Not checked

  • Which of the two flash parts a unit carries: the application reports both as flash 0x49 from manufacturer 0x01, as a Harmony 885 does, memory.md.6115
  • Whether the USB controller drops a report that arrives while a packet is programmed with interrupts off, and what the restart's write to it does.5

  1. Stated by Logitech, in their client. Section 207 ↩↩

  2. Read in the firmware. Section 113 ↩↩

  3. Read in the firmware. Section 114 ↩↩

  4. Read in the firmware. Section 116 ↩↩↩

  5. Not checked. ↩↩↩↩↩↩↩↩↩↩↩↩

  6. Measured on a unit. The test ↩↩↩

  7. Read in the firmware. The test ↩

  8. Measured on a unit. The test ↩↩↩

  9. Read in the firmware. The test ↩↩↩↩

  10. Read in the firmware. The test ↩↩↩↩↩↩↩↩↩↩

  11. Read in the firmware. The test ↩↩↩↩↩↩↩↩↩↩↩

  12. Read in the firmware. The test ↩↩↩↩↩↩↩↩

  13. Stated by Logitech, in their client. The test ↩

  14. Measured on a unit. The test ↩

  15. Read in the firmware. The test ↩

  16. Read in the firmware. The test ↩

  17. Measured on a unit. The test ↩

  18. Measured in configurations. The test ↩↩

  19. Measured on a unit. The test ↩↩

  20. Measured in configurations. The test ↩↩