Skip to content

Harmony One firmware

The Harmony One runs one program, the application, and keeps four smaller ones beside it: a bootloader that decides at power on what to start, a safe mode that can repair the remote, an image for its programmable logic, and a library that programs the external flash. Of the five, Logitech's package carries only the application, together with the configuration safe mode shows1. This page says where each lives, how the package that carries the application is laid out, and what safe mode can and cannot do. Where each sits in memory is memory.md.

The images

image version where it is stored where it runs
application 3.4 external 0x020000 to 0x02EA92, 60050 bytes, and a stored copy at 0x3D0000 in place at 0x020000, entry point 0x02EA3812; 0x020000 to 0x02002F is data, the header and a DEADDEAD fill, which a disassembler must be told, since 48 47 decodes as a valid instruction3
safe mode 3.44 internal 0xFE +0x1000 internal flash5
bootloader none, it has no header internal 0xFE +0x0000 internal flash, from the reset vector5
programmable logic image 1.64 internal 0xFF +0x0000 not known6
external flash programmer 3.44 internal 0xFF +0xE000 internal flash, called by the application and by safe mode7

The version block carries the versions of five images, in fields 7 to 11, and Logitech's client numbers them by region: 0 the bootloader, 1 safe mode, 2 normal mode, 3 the embedded configuration at 0x002000, 4 the user configuration at 0x040000, 5 the programmable logic and 11 the flash programmer library8. The table of regions with their addresses is in memory.md.

Every image but the bootloader opens with the same header: a u16 checksum, the size less eight, the version in BCD, the magic 48 47 at offset 8, and a GOTO to the entry point. The checksum XORs the even bytes into one seed and the odd bytes into another, 0x21 and 0x43, over the image from offset 4 to its end, so an image can be checked without anything to compare it with9.

The size is three bytes, offsets 4 to 6, which is how the safe mode image that installs an application reads it, so the byte at offset 6 is the size's top byte and never a family byte. On seven application images, of the Harmony One, 350, 600, 650 and 700, those three bytes plus eight are the length whose checksum verifies; the byte is 1 on the six over 64 KiB, the Harmony 350's among them, and 0 on the One's 60050 and on the Harmony 600, 650 and 700's safe mode images24.

Logitech's package, and where its parts load

Logitech's 3.4 package carries the application in one region file, Region_2.EZUpgrade, whose data decodes to 68952 bytes in two parts1:

bytes of the decoded region length loads at
0x00000 to 0x022C6 8902 external 0x002000, the safe mode configuration
0x022C6 to 0x10D58 60050 external 0x020000, the application

The file states the split itself, as two phases typed Configuration_Static and Firmware_Main, and the safe mode configuration's own header marks the same boundary10. The Harmony 600, 650 and 700's packages keep the two parts in separate files instead1.

The application a remote runs is the package's, byte for byte, both the copy at 0x020000 and the stored copy at 0x3D000011.

Safe mode, the bootloader and recovery

  • Safe mode copies nothing over the application, unlike the Harmony 525's, so entering it destroys nothing and a plain power cycle boots normally again512.
  • In safe mode only the software type in the version block changes, to 4, and the remote enumerates with the same product id, so enumeration cannot tell the two apart12.
  • Safe mode carries six of the application's seven commands, the same bytes and the same states, without 0x70 START_IRCAP, and both flash commands reach the external flash programmer, so it could rewrite a configuration with no protocol beyond what the application speaks713. It does not call the library for that: it carries its own byte identical copy of the programmer's routines, 601 bytes at 0x009CCA matching the library from 0x01E0187.
  • Safe mode reads the keypad itself, fifteen port reads from 0x004D8C on, PORTB, PORTA bit 4, PORTF and PORTG, the ports of the One's key matrix; that is what a running mode needs, and it says nothing about what enters safe mode25.
  • The bootloader is a USB flash programmer that enumerates as a Microchip device and writes internal flash only. At start it scans the keypad and compares two codes, 0x0E and 0x1E; the second runs the safe mode image without validating it5. Otherwise it checks only that the image at 0x1000 carries the 48 47 magic, so it validates that an image is present and not that it is intact10.
  • The application cannot erase its own configuration. Its only route to the external eraser is the USB ERASE_FLASH handler, which takes the address from the request, so an erased block of the configuration is always a host's doing. Programming, which the firmware does unasked, only clears bits14.

Which screen the 3.4 firmware draws

A screen held in a Harmony One's configuration is shown because the configuration's own instructions ask for it. The firmware itself picks a screen out of a configuration by number exactly once, for one status message; the other status messages it raises on its own come from a small status library or from its own code15. The detail, for anyone writing a configuration, counts over the 78 screens at the head of every compiled configuration's mode table:

Which of the 78 the 3.4 firmware draws by number: one. A mode becomes current only from an 0x7E operand, the mode stack (a mode that was current) or base slot 4, and base slot 4 is walked only for status code 9, "LCD Module Failed", after the licence check passed and while the configuration's verdict stands, so its key 9 (mode 19 in every compile) is the one screen the firmware takes from a configuration; codes 0, 26 and 27 are drawn from the status container at 0x002000 when it verifies and by the firmware itself otherwise, 25 is unreachable as read, and no caller raises the other 25. Of the head the configuration's own instructions enter modes 0, 1 and 9 (Low Battery, USB Connected, the charging problem) and no instruction the readers locate enters modes 2 to 8; on the sixteen compiles of skin 54 all 38 others are entered by the configuration, 30 from a key or touch, two Remote Assistant screens from the start and six blank screens by timers. Above the head one device list per compile is named by no enter at all. Harmony One 3.4 only; computed jumps, FSR writes and a computed 0x7E not excluded15.

The command handlers

What each command of the command table runs in the 3.4 application. A handler sets the state variable and parses its arguments, and the main loop does the work later1617.

command name state handler
0x10 GET_VERSION 1 0x264B4
0x30 WRITE_FLASH 2 0x264C2
0x50 READ_FLASH 4 0x2650C
0x70 START_IRCAP 5 0x26556
0xD0 ERASE_FLASH 8 0x2657A
0xA0 WRITE_MISC 9 0x26626
0xB0 READ_MISC 10 0x2671E

There is no 0x05 case, the escape's internal continuation the Harmony 600, 650 and 700 dispatch. The state variable is at 0x284, and while a flash write is in progress the dispatch goes to a two entry chain accepting 0x40 and 0xF0, at 0x267521617.

The configuration's constants

What the firmware does with two things a configuration states as numbers: the 0x3F instructions of band 0xC0 and the groups of the parameter block, base slot 15. The format of both is the configuration format's, the action language and state.

Where the configuration starts is never a literal in the application: no 0x002000 or 0x040000 reaches TBLPTRU anywhere in the 3.4 image, so the base arrives in a variable, and a search for the constant finds nothing to follow25.

The 0x3F band 0xC0

Confirmed on two configurations and two images, 106 uses each. The operand carries three fields, { bit 0; bits 1 to 3; bits 4 to 8 }, and the third is a five bit selector, so selectors 0 to 15 arrive with high byte 0xC0 and 16 to 31 with 0xC1. The handler accepts fifteen values and drops the other seventeen, and the configurations use exactly the fifteen22:

selector what it does uses per configuration
17 sets the display's light level: bits 1 to 3 choose one of eight states, bit 0 fades rather than snapping. States 2 to 5 take a level from base slot 15 group 1 and a pair of device levels from group 9, state 6 chooses the state from the measured band, states 0 and 1 turn it off23 68
0 to 12 sets channel selector of the I2C device at address 0x60 to the two bit value the byte table past base slot 15 group 9 states, for bits 1 to 3 being nonzero19 36
16 enables that device, LATC bit 5, set when bits 1 to 3 are nonzero19 2
13 to 15, 18 to 31 nothing: the handler falls to its exit 0

64 of the 68 are selector 17 state 6 without a fade. The band's uses are identical in both configurations, one of which has five devices and eight activities where the other has one and one, so nothing here varies with what the remote is set up to control. They are the compiler's fixed initialisation of the device at 0x60, one pass setting each channel off and one setting each on, and the firmware itself never enables that device: it only switches it off at shutdown. So a configuration that omits them leaves the device disabled19. What the device is, is on the Harmony One's hardware page; the base slot 15 groups are below.

Base slot 15's groups

From the routines that read them. Every default is a literal in the firmware, used when a group's length does not match, state2023:

group what it is the Harmony One's values default
0 the display light fade's per step delay 44 50
1 entries 2 to 5 are four display light levels, 0 to 27; entries 0 and 1 are read and discarded 38, 38, 20, 20, 26, 26 9, 16, 24, 27
4 three threshold pairs, two apart, turning the four sample sum of analogue channel 1 into a band 0 to 3 with hysteresis 96, 98, 308, 310, 768, 770 none
5, 6 two measurement to level curves over analogue channel 0, eight levels, chosen by the charger input on PORTB bit 1: group 6 when it is clear 3000 to 4051, and 3000 to 4170 none
7 a timeout in seconds, handed to the one second scheduler 0 10
9 four pairs at four bytes a band, both halves sent to the I2C device at address 0x60 as its registers 2/3 and 4/5; band 3's pair is past the declared entries 16, 16, 64, 64, 128, 128, then 255, 255 64

A level above 27 is silently refused by the setter, which a writer has to respect: 27 is the number of distinct CVREF voltages the part can produce, and the ladder that maps a level to one is in the firmware23.

Groups 5 and 6 are battery millivolts. The value walked against them is mean * A + ((mean * B) >> 16) where the mean is eight samples of analogue channel 0 and A and B are two u16 in the remote's own internal page 0xFF, giving 4.284 mV a converter count, and the firmware compares the result against the literal 340021. The thirteen two bit fields are channels of the I2C device at 0x60, whose part is not identified: thirteen channels of three states, two eight bit level registers, an enable pin and no readback19, the hardware page.

Not checked

  • A restore of a configuration through safe mode. The code for it is read, and it has never been performed18.
  • What the programmable logic does, and when its image is loaded into it18.
  • Any firmware but 3.4 on this architecture18.

  1. Read in the firmware. Section 3 ↩↩↩↩

  2. Read in the firmware. Section 1 ↩

  3. Read in the firmware. Section 10 ↩

  4. Measured on a unit. Section 23 ↩↩↩

  5. Read in the firmware. Section 189 ↩↩↩↩

  6. Measured on a unit. Section 206 ↩

  7. Read in the firmware. Section 191 ↩↩↩

  8. Stated by Logitech, in their client. Section 212 ↩

  9. Read in the firmware. Section 4 ↩

  10. Read in the firmware. Section 87 ↩↩

  11. Measured on a unit. Section 88 ↩

  12. Measured on a unit. Section 190 ↩↩

  13. Read in the firmware. Section 192 ↩

  14. Read in the firmware. Section 243 ↩

  15. Read in the firmware. Section 408 ↩↩

  16. Read in the firmware. Section 19 ↩↩

  17. Read in the firmware. The test ↩↩

  18. Not checked. ↩↩↩

  19. Read in the firmware. Section 106 ↩↩↩↩

  20. Read in the firmware. Section 44 ↩

  21. Read in the firmware. Section 105 ↩

  22. Measured in configurations. Section 102 ↩

  23. Read in the firmware. Section 103 ↩↩↩

  24. Read in the firmware. Section 295 ↩

  25. Read in the firmware. Section 118 ↩↩