Skip to content

Harmony 600: firmware

The 600 runs firmware 0.2. It is the same program as the Harmony 650's 0.2, built separately: the code sits at slightly different addresses and the build reports its own model number, and nothing else differs in meaning. Logitech names a newer version, 0.3, of which no copy is known to exist.

What the architecture's firmware is, how an image is laid out, what safe mode is, how a remote installs firmware, and which routines have been read on which build, is the architecture's firmware.md. This page states what is the 600's own.

Versions

version what evidence
0.2 the application, 70336 bytes, entry 0x1A26E, execution base 0x9000, read whole off a unit and verified by its own header checksum; safe mode 0.2, 24320 bytes 1
0.2 the forum table's newest seen, which is out of date 2
0.3 named for skin 71 by MyHarmony's own version list; the image it names answers 404, as every image on that list does 34

A newer version exists by Logitech's word and no copy of it is held. The version list in MyHarmony names 0.3 for skin 71, the 600 for the Americas, and has no entry for skin 733; that the image it names answers 404 is in no archive section or test yet4. Logitech's software update service answers 404 for skin 715. Logitech's update service holds the whole list.

The 600's 0.2 and the 650's 0.2

One program in two builds, 1395 bytes differing position by position, so an address read on one does not transfer to the other without checking6. Which routines have been found identical on both is the architecture's table of routines read and where.

What the 1395 bytes are: nearly all are code addresses that moved7. Two routines near the top swap places, one of 232 bytes at 0x19E02 on the 600 and one of 228 at 0x19D12. The 600's build carries 12 bytes the 650's lacks, two routines returning 0x74E and 0x74F that nothing calls, so everything from the USB descriptors at 0x19EEA up sits 12 bytes lower on the 650. The rest are references to moved code: 91 CALL and GOTO targets, 21 MOVLW literals and seven three byte pointers.

What differs in meaning is the model number: 71 in the version reply at 0x11964 and 0x1071 in the USB device descriptor, against the 650's 72 and 0x1072. So whatever draws the Off screen, or skips it, is the same code on both remotes7, behaviour.md.

No charging events

The 0.2 build posts no charging events: none of 0x1E, 0x1F, 0x20 to 0x25 or 0x30, the events the Harmony 700's 2.8 raises from its charger test, as far as direct posts go. It reads PORTB bit 1 as the cable's gate, as the 700 does. So the "Insert batteries" binding a 600 configuration carries is not raised that way on this model8.

Safe mode and recovery

  • The bootloader, the safe mode image and how safe mode is entered are the architecture's, its firmware.md. Entering safe mode by keys has not been tried on any unit of this architecture4.
  • The 600's 0.2 safe mode image carries part of the reinstall routine the Harmony 700 uses, and is otherwise unread, the architecture's firmware.md.
  • The 600 keeps a copy of its application in external flash at 0x000000, the image a reinstall would copy, memory.md. The reinstall route has been run on the Harmony 700 only9.

Not checked

  • Why the 600's and 650's 0.2 builds were built apart: what differs between them is read, above, and is moved addresses, two routines nothing calls and the model number7.
  • What the routine swapped near the top of each build is for: the 228 byte one drives a pulse train on LATG bit 0 and has no direct caller7.
  • What the 600's safe mode does with an update status byte of 2, end to end4.
  • Safe mode entry on a 600, by keys or otherwise4.

  1. Measured on a unit. Section 23 ↩

  2. Stated by a third party. The comparison table of harmony-remote-forum.de ↩

  3. Stated by Logitech. MyHarmony's firmware version list ↩↩

  4. Not checked. ↩↩↩↩↩

  5. Stated by Logitech, by their service. Section 295 ↩

  6. Read in the firmware. Section 281 ↩

  7. Read in the firmware. Section 392 ↩↩↩↩

  8. Read in the firmware. Section 384 ↩

  9. Measured on a unit. Section 295 ↩