Skip to content

Harmony Touch: the platform on the cable

A remote of this generation is talked to over USB by opening a named file, reading or writing through a handle and closing it, rather than by asking for bytes at an address1. Its configuration does not travel that way as a file at all: the remote fetches what it needs through the computer, which only carries the requests2. The protocol itself is the file protocol; this page is what this generation does with it. What this library does with a Touch, and the files it has read, is the Touch's usb.md.

Two protocols, chosen by the architecture number

Logitech's client picks a protocol from the architecture number: 9, 12 and 14 are its "legacy" list and take the command protocol of the Harmony 525, One, 600, 650 and 700, and every other number takes the file protocol3. Its templates divide the same way: 19 of their 23 skins take the file protocol and none takes both1. So 17 and 18, the two numbers this generation is given, get the same answer, which is why nothing in the client depends on which of the two a Touch is, README.md.

The Harmony 300 and 350 speak the file protocol too, and that is where its transport's rails are argued, their usb.md. What differs on this generation is below.

A write is checked by the remote, with MD5

A write through the file protocol ends with the host handing the remote five checksum parameters, a type, a seed, an offset, a length and an expected value, and the commit runs only if the remote answers that the file matches1. On this generation the type is MD5, with seed 0, in the Touch's package and the Ultimate Hub's; on the Harmony 300 and 350 it is an XOR of 16 bit words with seed 0x43211. What a remote answers to a write is not checked14.

Provisioning instead of a compile

Logitech's service does not compile a configuration for a Touch, and MyHarmony never asks it to. The client chooses a sync route from the capabilities the product declares4:

the product declares the route what happens
SupportsCertificateActivation or SupportsProvisioning provisioning the configuration is marked not required and the remote is provisioned
LocaleEnabled compile the service compiles, the client downloads the file and writes it

A Harmony Touch declares SupportsCertificateActivation and not LocaleEnabled; a Harmony One and a Harmony 600 declare the reverse4. Harmony Desktop agrees from its own side: of the skins it supports, it compiles for every one but 99, 102 and 112, the Touch, the Ultimate One and the 9505.

On the provisioning route the remote is the client and the computer is its network, and in the sync measured the whole proxy conversation went through one file on the remote, /sys/hlapi: the computer opens it for writing, writes one request, closes it, opens it for reading and reads the answer7. A request is a line of text naming an area and a command, vnd.logitech.setup/vnd.logitech.sync for example, with its arguments URL encoded after it; an accepted request is answered with the word Response, a comma and JSON, and a long request is announced first by a Content-Length line7. The seven skin 99 templates in Harmony Desktop's client that name /sys/hlapi use only open, write, read and close8.

A sync goes two ways, and the two are separate conversations. Changes made on the remote go up, when the client asks for them; the account comes down. Both were measured on a Harmony Touch through Harmony Desktop.

Up, the remote's own changes, measured once through Logitech's client, a hand over of changed settings9, and once through this project's answerer, where the remote handed up its whole Settings document with no tag in the same way, answering a sync13:

  1. the computer asks the remote to sync its own changes, then asks it for work, a proxy read naming a session
  2. the remote answered with one put request: the logical address of its settings and the whole settings document, URL encoded, with no entity tag; the document differed from the one last delivered in three settings, the screen and button brightness and the background
  3. the computer sent that document to Logitech's service, the same as parsed JSON, and wrote the service's answer back to the remote, again the same document, with its status, type and entity tag
  4. asked for work again, the remote asked for proxy://Finished, which is acknowledged; and when the computer asked a second time for the remote's changes, the remote had none and asked for proxy://Finished only

With nothing changed on the remote, the first list held only proxy://Finished7. The client asks for the remote's changes only when the account has no sync pending, among its other conditions: with edits waiting on the account, it goes straight to the sync down10. A sync down measured after edits on the account sent no request for the remote's changes, which is consistent with that9. Changes then waiting on the remote never reach the account: the sync request empties the queue that would carry them up, read in the firmware, setup12, and not seen on a remote14. This said what becomes of them was not checked until the handler was read.

Down, the account, measured twice, on an account without favourites or pictures and on one with both79:

  1. the computer reads the remote's provisioning information, then tries two writes the remote refuses, one of them its clock
  2. it tells the remote to sync and asks for work; the remote answers with six web requests, each the verb get and a logical address in Logitech's own scheme, harmony://..., with an entity tag: on all six in one sync measured, on all but the settings in the other; the settings going untagged is consistent with the remote saving them without a tag when a setting is changed on it, favourites and settings11
  3. the computer performs them against Logitech's service and writes all six answers back in one request, each the document with its status, type and entity tag
  4. with favourite channels on the account, the remote then handed over an empty list, and after it asked for one content address at a time: one content://1.0/user;..., one content://1.0/device;... and one content://1.0/service/<id>
  5. then for its pictures, in one list: the user's own, a background and its small twin, by absolute https address on Logitech's user image store, and the channel logos by the logical scheme, content-image://1.0/station/..., or content-image://1.0/image/... for a logo the user uploaded; each answered as a PNG, image/png, in base64
  6. it asks again, and the loop ends when the remote asks for proxy://Finished, which is acknowledged

Without favourites or pictures, steps 4 and 5 were absent and the remote asked for proxy://Finished straight after the six7.

The write to the clock, in both syncs down, was the time and a time zone into /sys/time, and the remote refused it with the error marker79; the hand over of changes wrote nothing to it9. Whether the clock is set some other way is not checked14.

The remote's configuration is documents of Logitech's service, in the syncs measured: the account's activity, device, button map and protocol lists, the remote's context and settings, and, with favourites, the user's, device's and service's content documents, favourites and settings, each as parsed JSON the same the service answered the computer, and every picture byte for byte the one fetched79. They are Logitech's own data model, the data model. So the host holds no compiled configuration for a Touch, and no amount of asking the service differently produces a file42.

What a host other than Logitech's server would have to answer, and what the remote checks of each answer, is answering a sync. Every name the remote answers on the cable and every request its engine takes through /sys/hlapi is the API.

This page said the whole conversation rides on the file protocol's request and response command, 0x08, which carries no file, and that the remote asks by absolute address with a resource name in each request, until a recorded sync showed neither: it sent no 0x08, the addresses were logical and a get carried no body7. The reading came from MyHarmony's proxy loop, with the command attributed by its description, while the client's own templates named /sys/hlapi all along8.

Reading a configuration back is switched off in Logitech's own template. The template that writes a Touch's user configuration carries the read of the same file commented out, under a header calling it "for testing only"1, and a Touch has no file at the Harmony 300 and 350's configuration path6.

Not checked

  • Whether the other products of the generation declare the same capabilities as the Touch14.
  • The request and response command 0x08, which a sync does not use7; what it is for14.
  • What a remote asks for when the account holds a Sonos, Roku, speaker or home control device, which the syncs measured did not involve14.
  • What a remote hands up for a change other than a setting, a favourite's order or a command14.
  • Whether MyHarmony, or another product of the generation, syncs the same way14.

  1. Stated by Logitech, in their client. Section 198 ↩↩↩↩↩

  2. Stated by Logitech, in their client. Section 203 ↩↩

  3. Stated by Logitech, in their client. Section 197 ↩

  4. Stated by Logitech, in their client. Section 202 ↩↩↩

  5. Stated by Logitech, in their client. Section 135 ↩

  6. Measured on a unit. Section 200 ↩

  7. Measured on a unit. The test ↩↩↩↩↩↩↩↩↩

  8. Stated by Logitech, in their client. The test ↩↩

  9. Measured on a unit. The test ↩↩↩↩↩↩

  10. Stated by Logitech, in their client. The test, class TheClientAsksForTheRemotesChangesOnlyWithNothingPending ↩

  11. Read in the firmware. The test ↩

  12. Read in the firmware. The test ↩

  13. Measured on a unit. The test ↩

  14. Not checked. ↩↩↩↩↩↩↩↩