Skip to content

Harmony 600, 650 and 700: firmware

The firmware is the program the remote runs; a configuration is the data it reads. On these three models the program is one program in several builds: the same routines, mostly at the same addresses within a build family, with the builds differing by model and version. So nothing read on one build transfers to another by address without checking1. The 600's and 650's 0.2 builds are one program: every differing byte is code that moved, a reference to it, the header checksum, two routines nothing calls, or the model number and USB release number each build reports, 71 and 0x1071 on the 600 and 72 and 0x1072 on the 6502. Each model folder lists its own versions; this file states what is common.

Builds

build model where it came from evidence
0.2, application 70336 bytes, entry 0x1A26E Harmony 600 read off a remote, its own header checksum verifying over all of it 3
0.2, application 70336 bytes, entry 0x1A262 Harmony 650 read off a remote 4
0.4, application 75392 bytes, entry 0x1B658 Harmony 650 Logitech's package, from a repair site 5
2.5, 71552 bytes Harmony 700 read out of a remote's staging region 6, 7
2.8, application 76672 bytes, entry 0x1BB38 Harmony 700 Logitech's package, installed on a remote by staging it 8

Every image loads at 0x9000, its header is 0x00 to 0x0F so its code starts at 0x9010, and its own checksum verifies91011. On the Harmony 600 the 0.2 entry point lies past the first 64 KiB, so only the complete 70336 byte image holds it, and a copy cut at 64 KiB loses it9. Logitech's software update service answers 404 for skins 66, 71 and 7212, so the packages above are all there is.

Routines read and where

Read on each build named. Where a build is missing it is not read.

routine builds read evidence
flash address classifier, ceiling 0x200000 600 0.2, 650 0.2, 650 0.4, 700 2.8 13, 14
external flash eraser, SPI 0xD8, 64 KiB the same four 14
cache drop, WRITE_MISC selector 0x02 600 and 650 0.2, 650 0.4, 700 2.8 15, 16, 17
restart, the escape's 0x02 600 and 650 0.2, 700 2.5 and 2.8 18, 15, 19
settings store read and write, 0x13 0xB2 and 0x14 0xB3 600 and 650 0.2; 700 2.8 reaches its own append, unread 20, 21
clock routines 600 and 650 0.2 22
state variable seeder 0.2, 0.4 16, 23
update status byte, WRITE_MISC selector 6 700 2.5 and 2.8; the 2.3 safe mode image 24, 25, 19
state variable storage sized from narrow + 2 * wide, everything above painted 0xFE at boot 700 2.8, 600 0.2; the bound check also on 650 0.2 26
state transition walker: every transition tested in record order and every match fired, -2 on any write and -3 on a change; a fired instruction runs next; the action queue holds 40 600 and 650 0.2, one routine; located on 650 0.4 and 700 2.8 27
configuration validator: GSPM at 0, LWJL at 0x5B, PTYY at end_addr, and the trailer checksum only while setting 0x80's bit 0 is set 600 and 650 0.2; 700 2.8, gated on 0x3A9 28
status screen routine and the five codes it is asked for 600 and 650 0.2 29
which infrared group a send plays, the toggle alternation 650 0.2; the same update found on 600 0.2, 650 0.4 and 700 2.8 30
pixel path, flash to panel in stored order 600 and 650 0.2, 700 2.8; its shape found on 650 0.4 31, 32
text draw: the font select keeps the set's address, a glyph found by its pointer 650 0.2, 700 2.8 33
queued screen program: base slot 11 entry operand & 0xff 600 and 650 0.2, 650 0.4, 700 2.8 34
picture and page list placement: nothing found reads a position 600 and 650 0.2, 650 0.4, 700 2.8 35
parameter group 3, a light's levels 600 0.2, 700 2.8 2
the section seeker: 0x0B + 4 * slot at 0x10B92, its callers loading raw slots 3 to 17 as literals, so one scan of its call sites names every slot's consumer 700 2.8 37, 38
the action dispatcher at 0x12F08: a switch on a selector routes a pointer into one of four subsystem slots, the infrared one at 0x3BD and 0x3BE 700 2.8 36
every configuration byte read: one SPI read primitive at 0x1B9AC, with its output twin at 0x1B984, reached through two accessors, so the configuration is read a few bytes at a time and is never mapped 700 2.8 36
a reset key combination: before the keypad scan three key intersections are probed, and one executes the processor's RESET while its key is held, at 0x19120, independent of any configuration; the other two gate whether that check runs 700 2.8 36
a cycle exact delay, a computed jump into a run of NOPs, at 0x10D00, the infrared carrier's timing and the most called primitive 700 2.8; at the same address on 600 0.2 36
the infrared receive timebase, TMR0 started and stopped around a learned edge, 0x19486 700 2.8 36
port initialisation, every port's direction and level set in one block near the entry, 0x1B8CE 700 2.8 36

The state variable seeder

At start the firmware writes each state variable's starting value, the first its record in the configuration states, state, unless a checksum says the variables already in memory are good, so a restart that keeps data memory keeps the running values. On the 600's and 650's 0.2 builds the seeder is at 0x16024, called from the boot path at 0x14F9C and from 0x0F39016:

  • It runs only when a container validated, the user container or the one at external 0x02000016.
  • The checksum is an XOR seeded 0xA5 over the variable array from its nineteenth byte, so the clock and the firmware's own variables are outside it: 174 bytes from data 0xE22 on the 0.2 builds, 237 bytes from 0x912 on the Harmony 700's 2.8 and the Harmony 650's 0.4. A matching sum makes the loop store nothing, and every store restamps the sum; where it sits is memory.md16.
  • Then a paint: 0xFE over everything above the table's size, the fill state describes16.
  • A user container that fails validation does not reload. That path ends in the paint from byte 18, so the configuration's variables are erased rather than reloaded16.
  • The 700 2.8 and the 650's 0.4 force a reload after a cache drop. The drop sets a flag, 0x1E9 on the 700 and 0x0E9 on the 0.4, which the next boot clears while spoiling the sum, at 0x1EC and 0x0EC, so the seeder reloads every variable. The 0.2 builds have no such flag1617.

How the seeder differs on the Harmony One and the Harmony 525 is state.

Safe mode

Safe mode is a second, smaller program the remote falls back on when its application or configuration cannot be used.

  • The safe mode image is in internal flash at 0xFE +0x1000; the safe mode configuration is in external flash at 0x020000, memory.md. On the Harmony One the arrangement is different, its memory page.
  • The -safe.bin trap: on this architecture the *-safe.bin file concordance writes when asked for the safe mode image holds the application truncated at 64 KiB, not a safe mode image: on a Harmony 600 it is the first 65536 bytes of the 70336 byte application3.
  • Safe mode reports software type 4 over USB, the application 0, the version block39.
  • The status screens a rejected configuration raises are the architecture's 3540, and a failed validation re-arms rather than latching, unlike the Harmony One41.
  • The status screens live in the safe mode configuration at external 0x020000, linked for that address42. One bit, data memory 0x68B bit 4 on the 0.2 builds, chooses whether a read goes there or to the configuration at 0x030000, and the status screen routine reads them from there with the configuration's verdict clear; the thirty status screens a user configuration carries are not drawn, as far as the 0.2 code reads29.
  • What a configuration must pass is its three markers. The checksum is checked only while setting 0x80's bit 0 is set, which it is not on the Harmony 600 and 650 read, so "Configuration Corrupted" can come from the configuration there only with that bit set28. A Harmony 650 ran a configuration that was the status screen library, moved, on those markers alone43.

Installing firmware

Nothing here writes the processor's flash. Two routes exist and both make the remote install:

  1. Reinstall what is staged: set the update status byte to 2 and restart, and safe mode copies the application staged at external 0x000000. Read on the 700's 2.3 safe mode image and run on a 700246; the 600's and 650's 0.2 safe mode images carry part of the routine, at 0x01A8C, and are otherwise unread24.
  2. Stage an image first: Logitech's own unmodified image written into external 0x000000 to 0x02000044; run on a 700, taking it from 2.5 to 2.88.

An install copies at most up to internal 0x1EC00, where the settings store begins: the install routine ends any copy there, so an application image can be at most 89088 bytes, 0x1EC00 less the 0x9000 it loads at24. The Harmony 700's 2.8, at 76672 bytes and ending at 0xFF +0xBB80, is well inside it8.

An interrupted install can be run again. The install routine erases every page of the application before it copies any, and it only reads the staged image, so a copy that stops part way leaves the safe mode image resident, the application erased past the break and the staged copy as it was, which is the state the same request starts from6.

The rails and the named doors are in usb.md and packages/usb/src/rails.ts.

Not checked

  • The Harmony 700's 2.8 build compared with the 0.2 builds routine by routine45. Why the 600's and 650's 0.2 builds differ is read: one program, its code moved and its model number its own2. This listed "Why builds of the same version differ between the 600 and 650" as not checked until then.
  • The 600's and 650's safe mode handling of the status byte, end to end45.
  • Safe mode entry by keys on any remote of this architecture: the bootloader compares two key codes, 0x14 and 0x2C39, which is a reading and has not been tried45.
  • The 0.4 package's validator and clock routines45.

The USB stack inside the firmware

Addresses in this section are the Harmony 700 2.8 image unless stated otherwise, read in its firmware46.

Attach

16e08: MOVLW 0x14      16e2c: MOVLW 0x1a      16e30: MOVLW 0x1c
16e0a: MOVWF UCFG      16e2e: MOVWF UEP1      16e32: MOVWF UEP2
  • UCFG = 0x14: UPUEN set, so the internal pull-ups are used and no external resistor is involved; FSEN set, so full speed; UTRDIS clear, so the on-chip transceiver; PPB = 00, so ping-pong buffering is off, which fixes the buffer descriptor table layout at four bytes per endpoint direction from 0x400.
  • UEP1 = 0x1A: EPHSHK, EPCONDIS, EPINEN. Handshaking on, control transfers refused, IN only.
  • UEP2 = 0x1C: EPHSHK, EPCONDIS, EPOUTEN. OUT only.

Both agree with the endpoint descriptors, and the agreement is three-way: the buffer descriptor for endpoint 1 OUT at 0x408 is never touched anywhere in the image, which is what UEP1 with EPOUTEN clear implies and what an endpoint descriptor set with no EP1 OUT requires46.

UCON bit 3, USBEN, is set at 0x17294, which is the attach46.

The report buffers

16e36: MOVLW 0x40   -> BD2OUT_CNT  0x411   64 byte capacity
16e3a: MOVLW 0x28   -> BD2OUT_ADRL 0x412
16e3e: MOVLW 0x04   -> BD2OUT_ADRH 0x413   buffer at 0x0428
16e42: MOVLW 0x88   -> BD2OUT_STAT 0x410   UOWN set, hardware may fill it now
16e48: MOVLW 0x68   -> BD1IN_ADRL  0x40E
16e4c: MOVLW 0x04   -> BD1IN_ADRH  0x40F   buffer at 0x0468
16e50: MOVLW 0x40   -> BD1IN_STAT  0x40C   UOWN clear, firmware keeps it

Every command the host sends lands at data address 0x0428, and every response is built at 0x0468. The two buffers are adjacent and 64 bytes each. The ownership bits are the right way round: the OUT descriptor is handed to the serial interface engine immediately, the IN descriptor is held by the firmware until it has something to send46.

From buffer to handler

The buffers are only ever reached through FSR, so pic18_trace.py cannot see them; the path was found through the accessors instead, using pic18_xref.py to walk callers46.

Address What it is
0x17332 returns 0x0428, the OUT buffer address
0x17344 returns 0x0468, the IN buffer address
0x1737A returns BD2OUT_CNT, so how many bytes arrived
0x1736A rewinds the OUT cursor and clears its count
0x17380 rewinds the IN cursor and clears its count
0x172C6 reads the next byte from the current packet
0x172DA appends a byte to the response and increments BD1IN_CNT
0x0BAFC copies a received packet out of the OUT buffer
0x0BD0A the command entry point, called from 0x1715E and 0x171E8

The interrupt service routine is 0x1AD80 to 0x1AF00: eight reads of UIR between 0x1ADE0 and 0x1AE4E, each followed by a bit test, dispatching on the interrupt source46.

The command handlers

What each command of the command table runs, on the two builds read for it. A handler sets the state variable and parses its arguments; the executor the main loop reaches for that state does the work4647.

command name state handler, 700 2.8 handler, 600 0.2 executor, 700 2.8
0x10 GET_VERSION 1 0x0BDFE 0x0BD68 0x0C906
0x30 WRITE_FLASH 2 0x0C21A 0x0C184 0x0D30C, through the test before the chain
0x50 READ_FLASH 4 0x0C266 0x0C1D0 0x0C982 starts a chunk, 0x0D3A8 finishes one
0x70 START_IRCAP 5 0x0C2B2 0x0C21C 0x0CB1E, a branch to the shared transmitter at 0x0D2E0
0xD0 ERASE_FLASH 8 0x0C2D6 0x0C240 0x0CB4A
0xA0 WRITE_MISC 9 0x0C364 0x0C2CE 0x0CB6E
0xB0 READ_MISC 10 0x0C4CE 0x0C432 0x0CB92
0x05 the escape's internal continuation 13 0x0C500 0x0C464 0x0CC46

Two states have an executor and no command: 3, a write transfer that has finished, at 0x0C95C, and 6 and 7, learning stopped, at 0x0CB204648.

The state variable is at 0xEC9 on the 700 2.8 and 0x1C1 on the 600 0.2. While a flash write is in progress, state 2, the dispatch goes to a two entry chain accepting 0x40 and 0xF0, at 0x0C55C on the 700 and 0x0C4C0 on the 6004647.


  1. Read in the firmware. Section 281 ↩

  2. Read in the firmware. Section 392 ↩↩↩

  3. Measured on a unit. Section 23 ↩↩

  4. Measured on a unit. Section 281 ↩

  5. Read in the firmware. Section 30 ↩

  6. Measured on a unit. Section 295 ↩↩↩

  7. Measured on a unit. Section 298 ↩

  8. Measured on a unit. Section 297 ↩↩↩

  9. Read in the firmware. Section 5 ↩↩

  10. Read in the firmware. Section 10 ↩

  11. Read in the firmware. Section 4 ↩

  12. Stated by Logitech, by their service. Section 295 ↩

  13. Read in the firmware. Section 192 ↩

  14. Read in the firmware. Section 281 ↩↩

  15. Read in the firmware. Section 282 ↩↩

  16. Read in the firmware. Section 283 ↩↩↩↩↩↩↩↩

  17. Read in the firmware. Section 299 ↩↩

  18. Read in the firmware. Section 97 ↩

  19. Read in the firmware. Section 298 ↩↩

  20. Read in the firmware. Section 304 ↩

  21. Read in the firmware. Section 305 ↩

  22. Read in the firmware. Section 310 ↩

  23. Read in the firmware. Section 284 ↩

  24. Read in the firmware. Section 295 ↩↩↩↩

  25. Read in the firmware. Section 297 ↩

  26. Read in the firmware. Section 276 ↩

  27. Read in the firmware. Section 332 ↩

  28. Read in the firmware. Section 354 ↩↩

  29. Read in the firmware. Section 355 ↩↩

  30. Read in the firmware. Section 365 ↩

  31. Read in the firmware. Section 367 ↩

  32. Read in the firmware. Section 387 ↩

  33. Read in the firmware. Section 368 ↩

  34. Read in the firmware. Section 369 ↩

  35. Read in the firmware. Section 328 ↩

  36. Read in the firmware. Section 13 ↩↩↩↩↩↩

  37. Read in the firmware. Section 35 ↩

  38. Read in the firmware. Section 81 ↩

  39. Read in the firmware. Section 87 ↩↩

  40. Measured in configurations. Section 244 ↩

  41. Read in the firmware. Section 253 ↩

  42. Measured in configurations. Section 353 ↩

  43. Measured on a unit. Section 354 ↩

  44. Chosen by this project. Decision 18 ↩

  45. Not checked. ↩↩↩↩

  46. Read in the firmware. Section 19 ↩↩↩↩↩↩↩↩↩

  47. Read in the firmware. The test ↩↩

  48. Read in the firmware. Section 175 ↩