The version block¶
The first thing a computer asks a Harmony over its cable is what it is. The remote answers with a short
block of bytes: which firmware it runs, its hardware version, which flash chip it carries, its
architecture, whether it is running normally or in safe mode, which model it is (its skin), the platform
it belongs to, and the versions of the other programs it keeps beside the one running. A Harmony One,
600, 650 or 700 answers with twelve bytes and a Harmony 525 with seven. readVersion in
packages/usb/src/protocol.ts is the library's reading of the block, and this page is its argument.
The request is GET_VERSION, the commands. Each model's own reply is on its usb page, for example the Harmony One's.
The request and the reply¶
Request: 0x10, with no arguments. The parser is inline in the USB callback at 0x0BDFE rather than a
separate handler, and it sets state 1, whose executor is 0x0C906 (Harmony 700 2.8)12:
0c908: 4f 0e MOVLW 0x4f ; a 16-bit pointer, 0x0D4F
0c90a: dd 6f MOVWF 0xedd
0c90c: 0d 0e MOVLW 0x0d
0c90e: de 6f MOVWF 0xede
0c910: 16 ec a1 f0 CALL 0x1422c ; fills the block at 0x0D4F
0c91a: 28 0e MOVLW 0x28 ; the response code
0c922: 6d ec b9 f0 CALL 0x172da ; append it
0c928: 5b 6b CLRF 0xd5b ; then copy 12 bytes from 0x0D4F
0c92a: 0c 0e MOVLW 0x0c
0c92e: 5b 5d SUBWF 0xd5b,W
0c930: 10 e2 BC 0x0c952
Reply: 0x28 then 12 bytes, copied out of a block that 0x1422C builds. It is twelve fields, and the
count closes: 0x1422C stores through the pointer in 0xEDD and 0xEDE at exactly twelve sites, from
0x142C0 to 0x143AE, one per field, and the executor's loop copies twelve bytes, and neither number was
derived from the other32.
The reply byte's low nibble counts the fields, and twelve is not universal4:
| remotes | reply byte | fields |
|---|---|---|
| Harmony 525 | 0x27 |
7 |
| Harmony One, 600, 650 and 700 | 0x28 |
12, by the firmware's own two counts above |
concordance reads the nibble as a length and branches on it, accepting 5, 7 or 8 and giving up the
architecture and the skin below 6 and the protocol below 75: the nibble counts where it is
small and is a floor at 8, and the firmware settles the real figure at twelve by copying twelve bytes. On
the request side nibble 8 would mean fifteen bytes, so as a length 0x28 does not fit the twelve that
follow; what its low nibble means, if anything, is not checked6. A host that expects twelve
fields refuses a 525's correct answer, which is why readVersion takes any block of seven bytes or more
and refuses a shorter one, which carries neither the architecture nor the skin4.
GET_VERSION's twelve bytes¶
Eleven of the twelve fields have a reading, from the accessors that fill them and from replies of remotes that differ in every one of the values. Six were first read off a Harmony 600 beside concordance's report for the same remote and then written down as a prediction for a Harmony One before it was read; the One answered with the first six bytes exactly as predicted37.
| field | Harmony 600 | Harmony One | reading |
|---|---|---|---|
| 0 | 0x02 |
0x34 |
firmware version, as two nibbles: 0.2 and 3.4 |
| 1 | 0x11 |
0x05 |
hardware version, as two nibbles: 1.1 and 0.5 |
| 2 | 0x1c |
0xc8 |
the second byte of the flash chip's id, below |
| 3 | 0x15 |
0x1f |
the first byte of the flash chip's id, below |
| 4 | 0xe0 |
0xc0 |
the architecture in the high nibble, 14 and 12, and the software type in the low |
| 5 | 0x47 |
0x36 |
the skin, 71 and 54, as a plain byte; bcdDevice states the same skin independently |
| 6 | 0x0c |
0x0c |
a platform, not the architecture |
| 7 | 0x02 |
0x34 |
the version byte at program 0x000017, in the boot area |
| 8 | 0x00 |
0x34 |
the version of the image at 0xFF +0xE000, from 0x01E007 |
| 9 | 0x00 |
0x16 |
the version of the image at 0xFF +0x0000, by pairing |
| 10 | 0x02 |
0x34 |
the safe mode image's version, from 0x001007 |
| 11 | 0x02 |
0x34 |
the running application image's own header version, from 0x009007 |
The rows' evidence: fields 0 to 5 by prediction and two remotes3; field 4 by its accessor38; field 6 by eleven images9; fields 7 to 11 by the program addresses their accessors build7.
- Fields 0 and 1 are packed by
0x14268, which takes two separately fetched values and packs them withSWAPF,ANDLW 0xF0andIORWF12. - Fields 2 and 3 are the flash chip's own id, and what the two bytes mean differs by architecture,
because one part is parallel NOR and the other is serial. On the Harmony 600, 650 and 700 the accessor
0x14244drops the chip select and0x10974sends the JEDEC0x9F, keeping two of the three bytes: field 3 is the capacity code, which the firmware compares against0x13,0x14and0x15to choose 512 KiB, 1 MiB or 2 MiB, and field 2 the manufacturer,0x1Cbeing EON's. On the Harmony One field 3 is the manufacturer,0x1Fbeing Atmel's, and field 2 the device. So the pair is written field 3 then field 2,15:1Cand1F:C8, and neither byte may be read as the same thing on both architectures10. The Harmony 525 answersFF:124. The Harmony 880 and 885's application does not report its part as read: it reports an Atmel1F:C0as01:49, keeps01:49, and answers anything else asFF:FF, so the01:49a running Harmony 885 gives does not say which part is fitted; their bootloader reports the part's own bytes, the platform's memory19. - Field 5 is the skin in plain binary, where
bcdDevicecarries the same skin in BCD on these remotes, the transport11. - Fields 8 and 9 version two images that only the Harmony One carries, the flash programmer and the
programmable logic image, and the Harmony 600 answers zero for both. That zero is a compiled in constant
on that architecture,
CLRF INDF0, and not an absent image answering; field 8 is proved by the address its accessor builds, and field 9 by the three internal images pairing onto three fields with the other two proved. Field 9's own accessor is a table read whose address does not explain its value7. - Fields 7, 10 and 11 repeat field 0 because they version things a firmware release stamps together: the boot area, the safe mode image and the running application7.
Two fields concordance reports are not in the block: its firmware type and its IRL, ORL, FRL have no
field here6. The third component of the hardware version it prints is not in the block at all:
concordance sets it to zero itself5.
The five compiled in fields¶
Fields 0, 4, 5 and 6 come from five consecutive RETLW instructions, in the order field 0, field 4's
low nibble, field 5, field 6, field 4's high nibble, so their values can be read off any image without
running it: at 0x10648 on the Harmony 700 2.8, 0x11964 on the Harmony 600 0.2, 0x138C8 on the Harmony
650 0.4 and 0x24262 on the Harmony One 3.432.
| image | field 0 | field 5 | field 4 high nibble | software type | field 6 |
|---|---|---|---|---|---|
| Harmony 700 2.8 | 0x28 |
0x42, skin 66 |
14 | 0 | 0x0C |
| Harmony 600 0.2 | 0x02 |
0x47, skin 71 |
14 | 0 | 0x0C |
| Harmony 650 0.4 | 0x04 |
0x48, skin 72 |
14 | 0 | 0x0C |
| Harmony One 3.4 | 0x34 |
0x36, skin 54 |
12 | 0 | 0x0C |
| Harmony 525 3.0 | 0x30 |
0x16, skin 22 |
9 | 0 | 0x09 |
| Harmony 880 4.4 | 0x44 |
0x0f, skin 15 |
8 | 0 | 0x08 |
| Harmony 885 4.4 | 0x44 |
0x11, skin 17 |
8 | 0 | 0x08 |
| Harmony One safe mode | 0x34 |
0x36, skin 54 |
12 | 4 | 0x0C |
| Harmony 600 safe mode | 0x02 |
0x47, skin 71 |
14 | 4 | 0x0C |
| Harmony 880 bootloader 4.0 | 0x40 |
0x0f, skin 15 |
8 | 3 | 0x00 |
| Harmony 885 bootloader 4.0 | 0x40 |
0x11, skin 17 |
8 | 3 | 0x00 |
Field 4's high nibble is the architecture and nothing else: three Harmony 600, 650 and 700 images with three firmware versions and three skins all report 14, the Harmony One reports 12, the Harmony 525 9, and the four Harmony 880 and 885 images 8. It matches the architecture each remote's own configuration states, and that is evidence rather than a tautology, because the accessor has exactly one caller and the firmware never compares the constant with the configuration32. The packing leaves four bits for it, so it can express fifteen architectures2.
Field 6 is a platform: 0x0C on the Harmony One and the Harmony 600, 650 and 700 alike, 0x09 on the
Harmony 525 and 0x08 on the Harmony 880 and 885, the lowest architecture number on each platform. The
Harmony One and the 600, 650 and 700 are one platform under it, which their shared processor family and
container cookies say too9. The bcdDevice high byte has a similar shape with different values, so
the two are not one variable11.
Software type, and what safe mode changes¶
Field 4's low nibble is the software type, from its own RETLW accessor beside the architecture one and
combined by the same SWAPF, ANDLW 0xF0, IORWF shape as fields 0 and 182.
Logitech names the values in the comments of its firmware packages, 0 and 4 being application mode and safe
mode, 1 test mode and 3 boot mode, and its client names all five: 0 application, 1 test, 2 minimal, 3
bootloader, 4 safe mode12. So the reply says which of a remote's firmware personalities is answering.
readVersion names the software type with those words.
What safe mode changes in the block is per architecture, because the remotes enter safe mode differently:
- On a Harmony One one byte of twelve changes: field 4's low nibble goes from 0 to 4, and a Harmony One
in safe mode answers
34 05 c8 1f c4 36 0c 34 34 16 34 34. Its safe mode image runs beside the application and copies nothing over it, so the flash id, the skin and the platform stay as they were13. - On a Harmony 525 three fields change, the firmware version, the software type and the platform: entering safe mode copies a different image over the application, so a different program, of a different generation, is answering, its usb page1413.
- On the Harmony 600, 650 and 700 a Harmony 700 in safe mode answers software type 415, and the
Harmony 600's safe mode image carries the platform
0x0Clike its application9. What else such a reply changes on a remote is not checked6.
So a caller learns the state from field 4's low nibble and must not read field 6 as saying it. A zero in field 6 is measured only from a Harmony 525 in safe mode14. On the Harmony 880 and 885 a zero is seen only in their two bootloader images, which are software type 3, and Logitech's classic client treats that bootloader as the platform's safe mode program, writing it when asked for the safe mode firmware, while the application carries a fallback configuration of its own, the platform's firmware92120. This asked whether a safe mode image exists on the Harmony 880 and 885 until the application's start was read20.
What Logitech's client reads from it¶
Logitech's client reads GET_VERSION when it identifies a remote and assigns the same six fields this page reads, in the same order: firmware and hardware version as nibble pairs, then flash device id, then flash manufacturer id, then architecture in the high nibble and software type in the low, then the skin16. Its naming of fields 2 and 3 is the Harmony One's reading, above. It names nothing past the skin. Its region numbers place fields 8 and 9 as the versions of the flash programmer and the programmable logic image, which agrees with the readings above, the Harmony One's firmware16.
One agreement and one contradiction. The client's file for the Harmony 525's skin declares a flash
device id of 0x12 and a manufacturer of 0xFF, and its file for the Harmony One declares 0xF9 and
0x01; no archive section holds those two statements6. A Harmony 525 reports exactly the first
pair4, and a Harmony One reports 0xC8 and 0x1F, not the second18. Either the One shipped with
more than one flash part or the file is wrong; either way a writer takes the flash id from the remote and
never from the client's table, and the write rails in packages/usb/src/rails.ts compare a
configuration's declared version against the version block the remote returns rather than against a
constant.
bcdDevice and field 5 on the remotes not yet read for it¶
The Harmony 700 2.8 image's device descriptor carries bcdDevice 0x1066 and the Harmony 650 0.2 build's
0x1072, BCD of 1000 plus the skin, where field 5 states the same skins as 0x42 and 0x48 in plain
binary1117. Neither has been read off a remote's bus6.
Not checked¶
- What the low nibble of the reply byte
0x28means, if anything6. - What field 9's accessor reads, given that its address does not explain its value7.
- What a Harmony 600 or 650 in safe mode answers beyond the software type6.
- What a Harmony 880 or 885 in its bootloader answers in field 6 on a unit6.
-
Read in the firmware. Section 19 ↩↩
-
Measured on a unit. Section 76 ↩↩↩↩
-
Stated by a third party. concordance ↩↩
-
Read in the firmware. Section 87 ↩↩
-
Read in the firmware. Section 109 ↩
-
Read in the firmware. Section 113 ↩↩↩
-
Stated by Logitech, in their client. Section 87 ↩
-
Measured on a unit. Section 190 ↩↩
-
Measured on a unit. Section 118 ↩↩
-
Measured on a unit. Section 295 ↩
-
Stated by Logitech, in their client. Section 212 ↩↩
-
Read in the firmware. Section 392 ↩
-
Measured on a unit. Section 57 ↩