Harmony 700: firmware¶
The firmware is the program the remote runs; the configuration a person builds is only data it reads.
This page says which versions of that program a 700 runs and how a 700 installs one. The architecture's
part, how an image is laid out, what safe mode is and the -safe.bin naming trap, is in
the architecture's firmware.md, and the images'
checksums are in docs/checksums.md.
Versions¶
| version | what | evidence |
|---|---|---|
| 2.8 | Logitech's package harmony_700_firmware_2_8__1_.hfw: application 76672 bytes, entry 0x1BB38, execution base 0x9000; the descriptor names Harmony Remote 0-2.8.0 and bcdDevice 0x1066, the transport. Installed and running on a 700 |
1, 2 |
| 2.5 | an application of 71552 bytes, run by a 700 and found in its staging region | 3, 4 |
| 2.3 | the safe mode image, 29888 bytes | 3 |
| 2.5.0 | the forum table's newest, which is out of date | 5 |
| 2.8 | the version MyHarmony's own list, VersionDbDefaults2.xml, names for the 700, so the 2.8 package is the newest Logitech names; the image it names answers 404, as every image on that list does |
6 |
The 2.8 build is the same program as the 0.2 builds at other addresses where it has been compared: its cache drop is the 0.2 drop relocated plus one flag7; its update status byte handler is 2.5's4; its restart is read8. The 2.8 image is also where this project's first firmware pass and the action list interpreter were read19.
Read on the 2.8 build since, all read in the firmware:
- The clock and the boot: the boot read of the configuration's build stamp fills the counter of time
since the build at
0xF0F, as on the other images10; the month end routine is at0x150DA, the same code as on every image, counting the day of the month from 011; the state variables sit at0x900 + n12, and the clock was read there over USB13. - The validator follows the end marker's address to the third marker as the 0.2 builds do, and gates
the trailer checksum on a bit at
0x3A9loaded from setting0x8014; the rest of its structure is at other addresses15, and it is not read further for the status screens16. - The display: pixels go from the flash to the panel twice per pixel, no swap and no buffer, in the
loop at
0x0E3A2, with SSP1 the flash and SSP2 the panel17; the panel set up keeps both variants of the 0.2 builds and adds two more, not read further18. - The charger test and the battery events, in hardware.md12. The instruction rate is 4 million a second: a 4 MHz crystal through the PLL with the processor clock divided by three, 16 MHz, from the first pass's measurement and the configuration words of the processor, and a timer tick is 1 ms121.
- The configuration's group 3 light: its routine is the twin of group 1's, states 6 and 7 included,
chooses between two setters, and drives
LATGbit 0 by pulses, cleared at level 0, where the 0.2 build uses a PWM; which light it is is not established19. - The settings command family carries the 0.2 builds' gate plus a third range of command states,
0xD0to0xD620, and a charger control, usb.md12.
Logitech's software update service answers 404 for skin 663; the 2.8 package comes from a repair site. MyHarmony takes a different route for this family, whose file name is unread, and whether Logitech still serves firmware for it is not established3.
Installing firmware¶
The 700 is the model both of the architecture's install routes were run on, and both make the remote install: nothing writes the processor's flash from the host.
- Reinstall what is staged: set the update status byte to 2 and restart, and the safe mode image copies
the application staged at external
0x000000. Read on the 2.3 safe mode image, and run on a 700 stuck in safe mode, which came back running 2.53. - Stage an image first: Logitech's own unmodified 2.8 image written into external
0x000000to0x020000, then the reinstall; it took a 700 from 2.5 to 2.82, under this project's rule that only Logitech's own image is staged21. The way back to 2.5 is the same route4.
Logitech's own sequence for skin 66 is the same five steps, firmwareupgrade.xml22. The limit on what
an install copies is the architecture's, its firmware.md.
Not checked¶
- The 2.8 build's clock seeder and validator in full; the parts listed above are read1014. This said "The 2.8 build's clock and validator routines" were not checked until those sections.
- Whether the 2.8 build queues the welcome tour's start, which the Off screen's mark waits for13.
- Entering safe mode on a 700 by keys; the bootloader compares two scan codes23, untried on this model24.
- Why a 2.5 application can lose a page of program memory, as on the 700 that arrived in safe mode3.
-
Read in the firmware. Section 13 ↩↩↩
-
Measured on a unit. Section 297 ↩↩
-
Read in the firmware. Section 298 ↩↩↩
-
Stated by a third party. The forum comparison table ↩
-
Stated by Logitech, in their client. MyHarmony's version list ↩
-
Read in the firmware. Section 299 ↩
-
Read in the firmware. Section 97 ↩
-
Read in the firmware. Section 34 ↩
-
Read in the firmware. Section 310 ↩↩
-
Read in the firmware. Section 322 ↩
-
Read in the firmware. Section 384 ↩↩↩↩
-
Measured on a unit. Section 386 ↩↩
-
Read in the firmware. Section 354 ↩↩
-
Read in the firmware. Section 257 ↩
-
Read in the firmware. Section 355 ↩
-
Read in the firmware. Section 367 ↩
-
Read in the firmware. Section 387 ↩
-
Read in the firmware. Section 392 ↩
-
Read in the firmware. Section 304 ↩
-
Chosen by this project. Decision 18 ↩
-
Stated by Logitech, in their client. Section 297 ↩
-
Read in the firmware. Section 87 ↩
-
Not checked. ↩