Skip to content

Harmony Touch API: system

The system requests are the button presses, the engine's own system information and usage events, the firmware names kept under harmony., the manual sync of an older client and the crash log. The button presses are what the remote's own screens send for every key and every touch, and the log and usage requests are theirs as well; the rest answer a client that asks. None of them is sent in a sync by Logitech's desktop client, usb.md.

Read in the production firmware 4.15.330, the build a Touch reports for itself; nothing here has been sent to a remote by this project1. Where a handler branches on the host name or the provisioning mode, the page says which branch a Touch takes, host name juniper and mode 0 or 1, the provisioning mode; the other branches are read and not checked against a unit2. How a name finds its handler, and the checks before it, are the API overview.

The requests

request what it does kind checks
control.button?press queues a button press action HasUsageLog, IsSyncComplete, WaitAccountRegistered, Default
control.button?fire queues a button press sent once action HasUsageLog, IsSyncComplete, WaitAccountRegistered, Default
control.button?hold queues a hold report of a button held down action HasUsageLog, IsSyncComplete, WaitAccountRegistered, Default
control.button?release queues a button's release action IsSyncComplete, WaitAccountRegistered, Default
harmony.system?systeminfo answers the engine's system information: architecture, skin, firmware, unit read Default
harmony.system?usagelog records usage events change HasParams, Default
harmony.firmware the firmware update machine, the twin of setup.firmware action Default
harmony.firmware?updateneeded the twin of setup.firmware?updateneeded read Default
harmony.firmware?updateinprogress the twin of setup.firmware?updateinprogress action Default
harmony.firmware?packageinstall the twin of setup.firmware?packageinstall action Default
harmony.firmware?packageremove the twin of setup.firmware?packageremove action Default
harmony.firmware?packagemanifest the twin of setup.firmware?packagemanifest read Default
harmony.manualsync?issyncrequired always answers that no sync is required read Default
harmony.manualsync?state always answers a finished, inactive manual sync read Default
harmony.manualsync?start raises, and so answers 500, doing nothing read Default
harmony.log?create records an event asking for the log change IsFWDownloadComplete
harmony.log?put sends the crash logs to a paired hub and deletes them change IsFWDownloadComplete
harmony.log?run uploads the crash logs on a hub; on a Touch prunes them change IsFWDownloadComplete
harmony.log?usage uploads the usage log, on a hub only action Default
harmony.log?reset resets the count of logs uploaded today change Default
harmony.log?enable turns logging on for named loggers change Default
harmony.log?disable turns logging off for named loggers change Default

The kinds are the API overview's. The three log requests that name only IsFWDownloadComplete run no default check at all, since a list of checks replaces it; on a Touch that check passes, so the difference shows only on a hub1.

Buttons

What a press does once it reaches the engine, which map and button it names, the long press, the number pad and sequences, is activities and buttons; this section is the request itself. The answer comes before any command is sent: each of the four queues an event and answers 200, and what the press did reaches the client later as a separate response, or as an announcement1.

control.button?press

Queues a press. Parameters, read by the handler and the event it queues1:

  • equadId, required: the identifier of the screens' map family, 16417 on a Touch, which the map's name starts with; without it the answer is 504
  • buttonKey, the button's name, or indexInMenu, a screen entry's place, used when there is no buttonKey
  • deviceId, optional: present in device mode, naming the device whose map is used
  • functionGroupType, optional: 2 takes the button from the number pad
  • sequenceId, optional: runs a sequence of the map instead of a button, used when no button is named
  • hidCode and cursor, optional: a keyboard code sent to a Bluetooth device instead of a button
  • timestamp, optional, the client's time of the press in milliseconds, and tsTimeout, optional: a press whose timestamp is more than tsTimeout, default one second, behind the engine's running estimate of the client's clock is dropped; without a timestamp the engine stamps the press with its own time
  • keyLatency, optional, default 0, passed to the infrared sender
  • ule and ulem, optional usage events, taken by the HasUsageLog check

It answers 404 when the button is an activity's and that activity is already queued or starting, so a second tap does not start it twice. A sequence the map does not hold is announced as finished with error 563 under the name control.button?sequenceFinished; a short press of a button that also has a long press is announced under control.button?pressType. Both are announcement names, not requests: the screens subscribe to them and the engine registers neither1. A button named DumpLog that no map holds sends nothing: its press starts a timer, and its hold handling, past four seconds, records an event for Logitech's log service and shows the screen for submitting logs; what follows on that screen is not checked2.

control.button?fire

The same press, sent once. It takes the parameters of control.button?press and queues the same event with the status fire: the infrared sender sends the command once, complete, where a press starts it and a release ends it. A button with a long press sends nothing on a fire unless a press of it is waiting, and then sends the short action1.

control.button?hold

A hold report. The screens send one every 300 milliseconds while a key stays down; the engine queues it, marked as a long press in the usage event, and answers 200. A hold is what fires a long press and what keeps a held key sending, activities and buttons 1.

control.button?release

A release. For a home control rocker key, a buttonKey that names a rocker or the home control plus or minus, it empties the home control queue, sends the release to the home control manager and answers 200. For any other key it clears the queued hold reports and queues the release, which sends the short action of a button with a long press when the long press has not fired. It is the one button request without the HasUsageLog check1.

System information and usage

harmony.system?systeminfo

The engine's own system information, as text: arch, always 0x11, then skin, usb_vendor_id and usb_product_id from the unit's manufacturing record, fw_ver, fw_type and hw_ver, both 0x00, and unit_id, joined by colons, with 200. No parameter1. This is what asks the engine for the architecture number, over /sys/hlapi like every request here, and it passes the default check on a Touch; why the number is 17 and how it differs from the native program's is firmware.

harmony.system?usagelog

Records usage events. Parameter events, a list, or event, one event; each is handed to the usage log, which keeps it for a later upload. It answers 2001. Its HasParams check cannot refuse, the API overview. The screens send it.

Firmware

The six harmony.firmware names reach the same handlers as their setup.firmware twins, with the same parameters and answers, setup; that page says which of them write or install firmware or software. The twins differ in one place: setup.firmware?reboot has no harmony.firmware twin, and harmony.firmware?reboot falls back to the bare harmony.firmware, which knows no reboot verb and answers 5001.

harmony.firmware

The twin of setup.firmware: with the verb update it installs an image in the cache and restarts the remote, with prepare it downloads one on a hub, and its other verbs check and report1.

harmony.firmware?updateneeded

The twin of setup.firmware?updateneeded: it always answers that no update is needed1.

harmony.firmware?updateinprogress

The twin of setup.firmware?updateinprogress; the screens subscribe to this name, not the other1.

harmony.firmware?packageinstall

The twin of setup.firmware?packageinstall: it installs a signed package and runs its installer1.

harmony.firmware?packageremove

The twin of setup.firmware?packageremove: it deletes a package folder by a name it does not check1.

harmony.firmware?packagemanifest

The twin of setup.firmware?packagemanifest1.

The manual sync

These three answer a sync driven by hand from a client and do nothing on this build1.

harmony.manualsync?issyncrequired

Always 200 with false. No parameter.

harmony.manualsync?state

Always 200 with the same text: the next state inactive, the action to continue, progress one of one and error 0. No parameter.

harmony.manualsync?start

Answers 500 and does nothing. The handler means to announce that the manual sync is done and answer 500, and raises before the announcement: it reads the request's headers from a variable named for the parameter table that the function names differently, which is unassigned, so the engine's own error answer, 500, is what returns1.

The crash log

The engine keeps crash logs and update logs in its cache folder and uploads them to Logitech's log service from a hub; a remote hands them to its hub over the radio1.

harmony.log?create

Records an event that the log was asked for, at information level, and answers 200. No parameter. Whether the event writes a crash log file of its own is not read2.

harmony.log?put

Sends the logs to a paired hub and deletes them. On a hub, mode 3, it saves the logs it is given under resource and answers 200 with them. On a Touch1:

  • in test mode, the file /etc/tdeenable present, it prunes the crash logs and answers 201
  • otherwise it answers 202 when a transfer is already running; with userRequest, it first asks the hub to upload what it holds; it then deletes the update logs in the cache, and sends each crash log to the hub over the radio as hot.1.harmony.log?put, deleting each the hub took, and asks the hub to upload. The first failure answers the hub's code; success answers 200

The screens send it when logs are submitted from the remote. With no hub paired the transfer fails and the logs stay, except the update logs, which are deleted before any transfer1.

harmony.log?run

Uploads the crash logs, on a hub. Parameter disableUpload, optional. It answers 202 while an upload it started less than ten minutes ago runs, and returns no reply when that upload is older, after pruning. Then it deletes the placeholder logs a failed delete leaves, and: with disableUpload, prunes and answers 201; while a sync runs, prunes and answers 202; in mode 3 with a network, uploads up to the day's limit of 100; on a Touch, prunes the crash logs to the newest 19 and answers 2011.

harmony.log?usage

Uploads the usage log, on a hub only: outside mode 3 it returns at once. It answers 200 either way1.

harmony.log?reset

Resets the count of logs uploaded today, writing the counter file, and answers 200. No parameter 1.

harmony.log?enable

Turns logging on. Parameters tags, a list of logger names, and mode, both required, 500 otherwise; each named logger is set to the mode, a name the logger does not know being skipped. It answers 200 1.

harmony.log?disable

Turns logging off for tags, required, 500 otherwise, with mode passed along when given. It answers 2001.

Not checked

  • What the native program does with the log transfer addressed to a paired hub2.
  • Whether harmony.log?create writes a crash log file2.
  • What older client sends the manual sync requests2.
  • The hubs' branches of these handlers, read and not checked against a unit2.