What the remote does in use, as a person holding it sees it. The operating concept, activities and device mode, is how a Harmony works, and this page does not restate it; it says how the 600 does it. Much of what has been seen on this architecture was seen on the Harmony 650, whose behaviour.md carries it; a row here is the 600's own.

The 600 plays no click on a key or a screen key: its architecture has no tone instruction1.

Device mode, in and out

how evidence
in the centre key below the display, under the word "Devices". There is no Devices key: the manual's button table lists every key and none is called Devices. The manual: "you select devices by pressing the center button below Devices", pages 5 and 6 2
choosing a device a list of devices, chosen with the arrows and the side keys, four to a page, page 9 2
a device's page that device's commands on the screen and its own keypad map, page 9; the keypad map is the device's own screen record 2, 3
out the centre key again, which then reads "Activity": "press the center button to return to Activities", page 9 2

The manual: "In some cases, you may want to control a device individually. You can use the device feature of the Harmony 600 to control devices one-by-one."2

Starting, switching and ending activities

  • An activity key starts its activity, or More Activities and a side key, and the remote "will take care of powering on the needed devices, and powering off the ones not needed", page 7. All Off "turns off all the devices in the current Activity", page 52.
  • A changed variable fires every transition that matches it, and a fired write fires its own: the routine that walks the transitions and both setters are byte for byte the 650's in the 600's 0.2 image4.
  • A configuration runs as its file predicts. A configuration of five devices and four activities, built by this project, sent every infrared frame as the device and command the file sends at that step, volume to the amplifier and channels to the set top box also after a visit to another device's pages5; and the delays the file states held, every gap between a device's power and its next command at least that device's power on delay6.
  • "Turning system off", the Off screen, did not show on leaving the cable or on All Off, on any run of a file of this project's stating model number 73, whether the mark it waits for was at 1 or at 076. With the same file stating 71, the number the remote reports, it showed very briefly after a start, one sighting, with All Off not reported on8. Three readings were open before that sighting, the model number, a light the 600's configurations set lower than the 650's, and a slower panel; the sighting favours the number without excluding a screen too brief to see8.

Help

Help resends what the running activity needs and asks "Did that fix the problem?"; held for five seconds it opens advanced help, where the delay between devices is changed on the remote, pages 8 and 222.

A delay saved on the remote wins over the configuration's at every start. A power on delay raised in the configuration was not heard, because the remote held a saved value for that device and copied it over the configuration's at start9. Which action on the remote saved it is not established10. The copy is the configuration's own program, so a configuration that does not carry it runs its own delays: a file of this project's with no restore ran its 0.5 s delay between devices while the remote held a saved inter device delay of 1.5 s, and no gap took the saved value6. The store itself is features.md and memory.md.

After a write, a restart or a rejected configuration

what happens evidence
a configuration block written back unchanged leaves the remote on the bus with no restart, since this architecture does not run its configuration in place 11
a whole write with the cache drop and the restart lands, and the remote runs it after the restart 9
the write's restart seeds the state variables from the file: a variable read over USB afterwards holds the value the configuration starts it at, both values tried 7
on the cable the configuration's state variables are live: the clock in variables 0 to 6 ticks between two reads, and a variable reads the value its configuration starts it at, from 0xE10 on build 0.2 9, 7
a configuration that fails validation does not latch the status screen until the batteries come out, as a Harmony One's does: the 600 has the same poll, flag and validator and arms without consulting the verdict, so a failed validation re-arms. The resting state of a connected 600 was measured; the failing case itself is not tried 12, 13
the trailer checksum is checked only while bit 0 of setting 0x80 in the settings store is set, and it was clear on the unit read, so the 600 accepts a configuration on its three markers alone; "Configuration Corrupted" can then come only from the configuration 14, 15

The state variables were once read as not loaded on the cable, on the strength of five journal variables that read zero; those are variables of another kind and say nothing about the configuration's7, the architecture's usb.md.

Not checked

  • Whether the 600 wakes when picked up; the manual says it does10.
  • The IR status indicator, and the introduction tour after a sync, both seen only on the 65010.
  • Advanced help's screens on a 600, and which of its actions saves a delay10.
  • What the 600 shows after a configuration fails validation10.
  • Why "Turning system off" shows with one model number and was not seen with the other, and whether it shows on All Off with 718.
  • Whether the remote counts devices at all; it ran six16.

  1. Read in the firmware. Section 74 ↩

  2. Stated by Logitech, in the manual. The Harmony 600 user manual ↩↩↩↩↩↩↩

  3. Read in the firmware. Section 271 ↩

  4. Read in the firmware. Section 332 ↩

  5. Measured on a unit. Section 389 ↩

  6. Measured on a unit. Section 391 ↩↩↩

  7. Measured on a unit. Section 387 ↩↩↩↩

  8. Measured on a unit. Section 392 ↩↩↩

  9. Measured on a unit. Section 303 ↩↩↩

  10. Not checked. ↩↩↩↩↩

  11. Measured on a unit. Section 302 ↩

  12. Read in the firmware. Section 252 ↩

  13. Measured on a unit. Section 252 ↩

  14. Read in the firmware. Section 354 ↩

  15. Measured on a unit. Section 282 ↩