Skip to content

Harmony Touch API: home control, harmony.automation?*

Home control is the part of Logitech's software that drives lights, blinds, locks and thermostats through their own hubs and bridges, which Logitech's software calls gateways: a Philips Hue bridge, an August lock, an Insteon hub and others, each reached by a plugin. These fourteen requests discover a gateway, pair with it, read and set its devices' states and run a few utilities. They are a hub's: the image registers them on a Harmony Touch as well, and on a Touch synced through a computer every one of them is refused before its handler runs, for want of the configuration they work on. How a request line reaches the engine over the cable is the API overview.

Everything here was read in the Touch's production firmware, build 4.15.330, in the engine and in the screens; nothing was sent to a remote1. A Touch's host name is juniper and its provisioning mode, as measured, 03. What the handlers do past their checks is the hub's behaviour as the shared engine states it, and is not checked on a hub.

Why every request is refused on a Touch

The home control configuration is a document of its own, AutomationConfig, holding the gateways, the devices, the groups, the scenes and the programs; it is none of the documents of devices and infrared, activities and buttons or favourites and settings. Every request in this group checks for it before anything else but a running sync, and refuses with 587, a missing-home-control-configuration refusal, when the remote holds none1.

A Touch that syncs through a computer never fetches it. The request list the remote hands the computer names six documents, and in modes 3 and 4 a seventh, the capability list, and never the home control configuration; the lists that name it are a hub's own, fetching from Logitech's service, and the one a remote uses to sync from a hub, the platform on the cable1. So on a Touch every request below answers 587.

And the home control task does not start on a Touch. The engine's home control task returns at once on the host name juniper, so it sets up no plugin when the remote starts; a plugin is otherwise marked ready by its own setup or by a successful pair, which the 587 refusal stops first1.

A document of that kind could still arrive: a resource put names the home control configuration by its address, which the engine maps to AutomationConfig, so a direct put, answering a sync, would store one and lift the refusal1. What the requests then do on a Touch, with no plugin started and no network of its own known, is not checked4.

The requests

The kinds and the shared verifiers are as on the engine's page. This group adds a check of its own before the default one, verifierGetAutomationConfig, and five requests a second, below.

request what it does kind verifiers
harmony.automation?discover searches the network for gateways action IsSyncComplete, verifierGetAutomationConfig, Default
harmony.automation?pair pairs with a gateway action IsSyncComplete, verifierGetAutomationConfig, Default
harmony.automation?getstate the states of home control devices read IsSyncComplete, verifierGetAutomationConfig, verifierGetState, Default
harmony.automation?setstate sets the states of home control devices action IsSyncComplete, verifierGetAutomationConfig, verifierSetState, Default
harmony.automation?remove removes a gateway action IsSyncComplete, verifierGetAutomationConfig, verifierRemove, Default
harmony.automation?toggle switches a group's or a gateway's lamps off, back, or on action IsSyncComplete, verifierGetAutomationConfig, verifierToggle, Default
harmony.automation?refresh asks gateways to refresh their devices action IsSyncComplete, verifierGetAutomationConfig, Default
harmony.automation?status each gateway's status read IsSyncComplete, verifierGetAutomationConfig, Default
harmony.automation?addprogram stores a program in the home control configuration change IsSyncComplete, verifierGetAutomationConfig, Default
harmony.automation?adddevice adds a device to a gateway action IsSyncComplete, verifierGetAutomationConfig, Default
harmony.automation?removedevice removes a device from a gateway action IsSyncComplete, verifierGetAutomationConfig, Default
harmony.automation?getutilitymenu the utility menu entries the gateways' plugins offer read IsSyncComplete, verifierGetAutomationConfig, Default
harmony.automation?indicate passes a device's own report to its plugin change IsSyncComplete, verifierGetAutomationConfig, Default
harmony.automation?identify makes a device blink so a person can find it action IsSyncComplete, verifierGetAutomationConfig, Default

None of the fourteen restarts, erases, resets or writes firmware. Two write the stored home control configuration, addprogram and remove for an unsupported gateway, and the rest act on gateways and devices over the network1.

The verifiers of this group

verifier what it checks on a Touch, from the cable
IsSyncComplete refuses with 202 while a sync runs, the API overview as there
verifierGetAutomationConfig reads the stored home control configuration and refuses with 587 when there is none; otherwise prompts the activity engine to run its programs, which it does only in mode 3, and passes refuses, as above
verifierGetState notes the devices asked about for the default verifier's policy, and marks the request a read never refuses
verifierSetState refuses with 504, a missing-states refusal, without state or a JSON object; otherwise notes the devices and marks a write refuses a request with neither
verifierRemove refuses with 504 without gatewayId; otherwise marks a write refuses a request without it
verifierToggle refuses with 589, a bad-arguments refusal, unless groupId names a group with devices or gatewayId is given; marks a read and a write refuses as stated
Default the policy check those notes feed checks nothing on juniper, answering a sync2

So on a Touch the four second verifiers are never reached, and the policy notes they make would be read by a check that is switched off1.

Arguments. getstate, toggle, refresh, status and addprogram unpack a JSON object sent as one argument, and setstate takes such an object as its whole map of states; the others read only names and text values, the API overview1. Every request here answers at once, so a cable host receives each answer.

Each request

harmony.automation?discover

Searches the local network for gateways of one kind, or of every kind the image has a plugin for, and keeps what it finds in memory for pair1.

Handler: discover in tasks/automation/apihandler/automation.lua.

Parameters: type, gatewayType: either names a plugin; with neither, every plugin under tasks/automation/plugins is asked, which in this build are August, ecobee, Honeywell, Hue, Hunter Douglas, Insteon, LIFX and WeMo.

What it does. Forgets the gateways found before, then asks each plugin's discovery.

Answers. 200 with the gateways found, as JSON; 580, a none-discovered answer; 592 when a named plugin is not there1.

Who calls it. Nothing on the image sends this name1.

harmony.automation?pair

Pairs with a gateway, by the plugin of its kind, and marks that plugin ready1.

Handler: pair in tasks/automation/apihandler/automation.lua.

Parameters: gatewayId, gateway, authUri.

  • gatewayId or gateway is required, or 504. gateway is the gateway's description itself; gatewayId finds one among those discover found, then among those the configuration holds, or answers 504, a none-found refusal.
  • authUri: an address, given in the request, from which the remote fetches a secret for the gateway, adding to it a key the firmware carries; a failure answers 581.

Answers. 200; 582, a pairing-failed error; 592 when no plugin of the gateway's kind is there.

Who calls it. Nothing on the image sends this name1.

harmony.automation?getstate

The current states of home control devices, as their plugins report them1.

Handler: getstate in tasks/automation/apihandler/automation.lua.

Parameters: gatewayId, deviceIds, groupId, forceUpdate.

  • One of gatewayId, deviceIds, a list, or groupId narrows the devices; with none, every gateway's.
  • forceUpdate: passed to the plugin, which may then ask the device rather than answer from memory.

Answers. 200 with a JSON object of states by device; a device whose plugin gave nothing is reported with status 2 and nocon, and a gateway whose plugin is not ready reports its devices with status 2 and notrdy; 583 when there is nothing at all1.

Who calls it. The screens' home control interface, hainterface.lua, which asks only when it finds a home control configuration among the remote's documents itself; and, in mode 3, the activity engine, to seed the state its rules compare against1.

harmony.automation?setstate

Sets the states of home control devices, a light's power and brightness for example1.

Handler: setstate in tasks/automation/apihandler/automation.lua.

Parameters: state: a map from device to the state wanted; or the whole request as a JSON object of that map. One of the two is required, or 504.

What it does. Groups the devices by plugin, drops null values from each state, and hands each plugin its devices, all at once when it can take several; it records a usage count per plugin1.

Answers. 200; 584 when any plugin failed.

Who calls it. The screens' home control interface, hainterface.lua, under the same condition as getstate; and, in mode 3, the activity engine when a rule sets a state1.

harmony.automation?remove

Removes a gateway: its plugin forgets it and is unloaded1.

Handler: remove in tasks/automation/apihandler/automation.lua.

Parameters: gatewayId, required, or 504.

What it does. Asks the gateway's plugin to remove it, stops the plugin and unloads it. For a gateway of four kinds the image no longer has plugins for, rheem, icontrol, danalock and zulidemo, it deletes the gateway and its devices from the home control configuration and stores the result through a resource put, which also queues it for the account1.

Answers. 200; 585, a removal-failed error.

Who calls it. Nothing on the image sends this name1.

harmony.automation?toggle

Meant to switch a group's or a gateway's lamps: off when any is on, remembering how they were; back to how they were; or on at full brightness when nothing is remembered1.

Handler: toggle in tasks/automation/apihandler/automation.lua.

Parameters: groupId or gatewayId; without either, 589.

What it does, as read. The test for a lamp names a variable the function never sets, so no device passes it, nothing is switched and the request answers 200 having done nothing1. That reading has not been seen on a hub4.

Who calls it. Nothing on the image sends this name1.

harmony.automation?refresh

Asks gateways to refresh what they know of their devices1.

Handler: refresh in tasks/automation/apihandler/automation.lua.

Parameters: gatewayId; without it, every gateway whose status is ok.

Answers. 200; 588, a refresh-failed error, when any plugin failed or was not ready.

Who calls it. Nothing on the image sends this name1.

harmony.automation?status

Each gateway's status, as its plugin reports it1.

Handler: status in tasks/automation/apihandler/automation.lua.

Parameters: gatewayId; without it, every gateway.

Answers. 200 with the statuses by gateway, a plugin not ready giving errorStatus 3; 583 when there is none; 592 when a plugin is missing1.

Who calls it. Nothing on the image sends this name1.

harmony.automation?addprogram

Stores a program, the activity engine's rule set, in the home control configuration and restarts the activity engine on it1.

Handler: addprogram in tasks/automation/apihandler/automation.lua.

Parameters: program and programId, both required, or 504.

What it does. Only in mode 3: elsewhere it answers 500, a not-in-hub-mode refusal, which is how this page knows mode 3 is the hub's. In mode 3 it writes the program into the configuration, stores it through a resource put, queued for the account as well, and announces the change to the activity engine1.

Answers. 200, or 500 outside mode 3.

Who calls it. Nothing on the image sends this name1.

harmony.automation?adddevice

Adds a device to a gateway through the gateway's plugin, such as a new bulb to a bridge1.

Handler: adddevice in tasks/automation/apihandler/automation.lua.

Parameters: gatewayType, required, or 504; deviceInfo, timeout, cancel and done, passed to the plugin.

Answers. 200 with the devices added; the plugin's error, or 596; 592 when the plugin is missing or not ready.

Who calls it. Nothing on the image sends this name1.

harmony.automation?removedevice

Removes a device from its gateway through the plugin1.

Handler: removedevice in tasks/automation/apihandler/automation.lua.

Parameters: gatewayId, deviceId, gatewayType: one is required, or 504; timeout and cancel, passed to the plugin.

Answers. 200; the plugin's error, or 597; 592 when the plugin is missing or not ready.

Who calls it. Nothing on the image sends this name1.

harmony.automation?getutilitymenu

The extra menu entries the gateways' plugins offer, in a language1.

Handler: getUtilityMenu in tasks/automation/apihandler/automation.lua.

Parameters: language.

Answers. 200 with utilities; 592 with what was gathered when any plugin is missing or not ready.

Who calls it. Nothing on the image sends this name1.

harmony.automation?indicate

Passes a report a device sent of itself, a value at a path, to the device's plugin1.

Handler: indicate in tasks/automation/apihandler/automation.lua.

Parameters: type, dev, path and value, all required, or 504. dev is the device's hardware address with underscores for colons, matched against the configuration's devices.

Answers. 200; 587, a device-not-found error; 592 when the plugin is missing.

Who calls it. Nothing on the image sends this name1.

harmony.automation?identify

Makes a device show itself, by switching it back and forth, so a person can tell which it is1.

Handler: identify in tasks/automation/apihandler/automation.lua.

Parameters: deviceId or cancel, one required, or 504. cancel stops one under way.

What it does. A plugin with its own way of identifying is asked to use it, and its answer is the answer; otherwise a task toggles the device's state ten times, 600 ms apart, or a second apart for a lock, and then restores what it was1.

Answers. 200; 592 when the plugin is missing or not ready.

Who calls it. Nothing on the image sends this name1.

Does any request read a document back

No. getstate, status and getutilitymenu report what plugins say about gateways and devices, not the stored home control configuration, and on a Touch none gets that far1. The home control devices, groups and scenes of the stored configuration are what harmony.engine?getallhadevices returns, where there is one.

Not checked

  • Every handler past verifierGetAutomationConfig, on any remote: read in the shared engine only4.
  • What these requests do on a Touch after a direct put of a home control configuration4.
  • That toggle does nothing, which rests on the decompiled reading of one variable4.
  • Whether the activity engine's prompt from verifierGetAutomationConfig does anything outside mode 34.
  • Other host names, other modes, other builds and other products of the generation4.