Skip to content

Harmony 300 and 350: firmware

The two models' applications are one program linked twice, and the images below it are not shared. Read off a Harmony 300 and off a Harmony 350, the two applications are the same code with one routine changed and every address after it moved by up to ten bytes; their bootloaders are different builds and their safe mode images are different versions, 1.2 on the Harmony 300 read and 1.4 on the Harmony 35029. Logitech's package manifest names the Harmony 300's two skins and the Harmony 350's for one image, which is a statement about the package: the one image in it is what a Harmony 350 runs and is not what the Harmony 300 read runs29. Both are ordinary PIC18 programs like the Harmony 600's. Each model folder's firmware.md points here, and the comparison is below.

The 1.4 image

value evidence
package a ZIP holding Description.xml and Region_2.EZUpgrade, whose <INTENDED> names skins 78, 79 and 104, written to /fw/normalmode 1
version 1.4, in the manifest and the image header; MyHarmony's version list also names both models at 1.4.0 1, 2
decoded 73472 bytes, an HG header that verifies, an ordinary PIC18 image 3
load base 0x9000: 1581 of 1582 branch targets land on a boundary there, 99.9%, against 475 of 1460 for the runner up at 0xC000, 32.5%; the instruction at 0x9000 is GOTO 0x1AED4 and the header's own entry point field is 0x1AED4, so the base has a closure and not only a score. It agrees with /fw/normalmode's own row in the file table 3, 4
the checksum Logitech's manifest states the XOR of little endian words configuration containers use, seeded 0x4321, the container 1

Where it comes from: Logitech's software update service, production channel, by product and with no login1. MyHarmony asks that service for the Harmony 350 by name, where the Harmony 600, 650 and 700 take another route5.

The two models' images compared

The package image is the Harmony 350's application, byte for byte: a Harmony 350 serves /fw/normalmode as the package's first 73464 bytes, and the package's last eight are 0xFF, the eight the remote does not serve because it states the header's length, which is 8 short29. A Harmony 300 serves a different build of the same version. Its header states the same version, 1.4, and the same length, 73472, but the two images differ in 37809 of 73464 bytes read straight across, which is what a shift of up to ten bytes does to every address operand29. Aligned instruction by instruction with the address operands masked they are one program, and these are the only places the two differ, the Harmony 350's addresses first28:

Harmony 300 Harmony 350
header checksum, entry point 0xAF6A, GOTO 0x1AECA 0x8F7B, GOTO 0x1AED4
where the code ends 0x1AEEE, 0xFF to 0x1AEF8 0x1AEF8
USB bcdDevice, one word of the descriptor constant 0x1078, at 0x1AC06 0x1104, at 0x1AC10
the 0x7D arm, a send, at 0x1134E in the 350 stores the group's send kind as it stands stores the kind AND 3, at 0x11356, 0x1136A and 0x11384
a CALL at 0x11A8C an RCALL to the same target a CALL, since the ten bytes before it put the target out of range

Every other instruction is the same: 30579 equal byte for byte, 1083 calls and jumps and 54 relative branches whose targets moved by the shift of the place they point at and nothing else, and 9 pointer bytes loaded as literals, each the 300's plus the shift28. The shift, 350 against 300, is 0 below 0x11356, 2 from 0x11358, 4 from 0x1136E, 8 from 0x1138A and 10 from 0x11A90, so an address quoted on this page for the application is the 300's with that shift added, and is the same in both below 0x11356. The product string Harmony Remote 0-1.4.0 is the same in both.

What the one changed routine does. The action list dispatcher's arm for 0x7D maps the operand's high byte, the infrared group, to a send kind in 0x203 before it calls the send handler: group 0 stays 0 and 3 stays 3, 1 becomes 2 and 2 becomes 1, and any group from 4 up becomes 0xFF. The 350's build then keeps only the low two bits, so a group from 4 up is kind 3 there, where the 300's leaves 0xFF28. The kind picks the firmware event the send raises, 0x2D for 0, 0x2F for 1, 0x2E for 2 and 0x30 for 3, the key tags below 0x40, and any other kind is a default that raises event 0xFF. This said that 0xFF raised 0x2D, group 0's event, until the chain's end was read again: the BNZ after its last step is the default and the fall through is kind 030. So the two builds disagree for one input only, a send from a group above 3: the 350 raises the event of group 3 and the 300 raises event 0xFF, to which none of the 13 configurations of the family read, Logitech's compiles among them, binds anything30. Logitech's service holds a Harmony 300 to four infrared groups and a Harmony 350 to eight, which is a choice of the service and not of the remote, the README, so a configuration it compiles for a 300 cannot reach the difference and one for a 350 with more than four groups can. Of the 13 configurations of the family read, four send from a group above 3 and all four are the 350's: Logitech's compile of the test setup and its first compile and the eight device compile, whose groups reach 7, and a contributed 350's, which reaches 532.

What a send does with its event, and why event 0xFF stops it. Entry 0 of every configuration binds each of the four events to one list, and the four lists are one list on four output pins: a test of the sending flag, state variable 17, with two arms that set the pin one way and the other, then the 0x07 FFFA the compilers append. 0x2D switches pin 0, 0x2F pin 1, 0x2E pin 2 and 0x30 pin 3, and in all 13 configurations 0x2D's list and 0x30's differ in the pin and in nothing else32. The pin routine, at 0x14568 on the 350 and 0x1455E on the 300, is the same instructions in both images: pin 0 is PORTC bit 1, pin 1 PORTB bit 0, pin 2 PORTB bit 2 and pin 3 PORTB bit 3, set for a zero value and cleared otherwise32.

The send waits for its event's list. Raising an event queues it and sets bit 4 of the flag byte 0x8A, and the one thing that clears that bit is the dispatcher's arm for 0x07 with operand 0xFFFA, which is the last instruction of every one of the four lists. The sender's step, at 0x12BA8 on the 300, returns at once while the bit is set, and the send's own state changes each raise the event again, so a send moves from one step to the next only after the list of its event has run to its end30. With event 0xFF no list is bound, none runs, the bit stays set and the sender stays in its first state: a Harmony 300 given a send from a group above 3 queues the code and never transmits it, and every later send queues behind it30. A Harmony 300 holding such a configuration did exactly that on a unit: the group above 3 sent nothing, the remote then ignored most keys, and a device key stayed lit until the batteries came out31. Binding event 0xFF to the list event 0x30 runs removes the hang: the same configuration with that one entry sent from groups 4 to 7 on a Harmony 300 and the remote kept answering, the README31. That the later keys failed for the reason traced, which the entry's removing the hang supports and no trace reads, and that the pins are the device key lights, are not read10. The acknowledgement is read on this family only, the Harmony One's and the Harmony 600, 650 and 700's are not checked.

The bootloader and safe mode differ more, below.

Routines read on it

Addresses here are the Harmony 350's, from the package image; for a Harmony 300's application subtract the shift above.

routine evidence
the file table and the name pool 4
the configuration test the host's check runs, at 0x14AC2: GSPM compared from 0x14AE8, LWJL at the hardcoded 0x47, then the stored checksum word returned rather than recomputed. Section 259 called it the configuration validator; the validator that runs at start is the next row 6, 7, 12
the configuration validator at 0x16090, run at start and from a second call site in the main loop while the verdict is clear: GSPM, LWJL at 0x47, PTYY at end_addr and the trailer checksum, below 12
the file protocol: the request parser at 0xCB88, the reply dispatcher at 0xE2F0, the file lookup at 0x12CF0, the close at 0x12CE6, the read size of /cfg/usercfg at 0x14C58, usb.md 12
the section seeker, 0x0B + 4 * slot at 0x10BCE on the 350's 1.4 image, called for raw slots 3 to 12 from 14 call sites 6
the readers of raw slots 5, 6, 8, 9 and 12: the start up event table at 0x11D48, called once from the validator's tail at 0x162B8; the key map lookup at 0x1113A and its tagged list reader at 0x1AB24; the timer start at 0x16A2E and the expiry pass at 0x1694A; the state variable seeder at 0x16E6C and the record locator at 0x17360; the digit entry reader at 0x19D56. What each slot is, memory.md 18
the keypad scan at 0x1892A, its returns at 0x188C8, and the key events it raises: press at 0x18B4A, release at 0x18B84 and 0x18BCE, held at 0x18AEA; the firmware's own events at 0x145E2 and 0x11EA6, below 26
the keypad's three events, raised at 0x18AEA, 0x18B4A, 0x18B84 and 0x18BCE; the hold counter at 0x312, started at 0x1959E and decremented from 0x19708; parameter 0, the hold time, written by 0x3F band 0xF0 at 0x117C4, below 22
the month end routine of the clock, at 0x14382 8
the state variables: the reader at 0x17302 and the store at 0x172B2, from data memory 0x108; the tick at 0x13C12, which adds the time elapsed to the second; the minute's step queued at 0x13E52; bands 0xF2 and 0xF1 of 0x1F at 0x11984, one added to a variable or taken off it, wrapping through its max at 0x171E8; the reply carrying the clock at 0x0F3BE. What they add up to, memory.md 19
the state variable bound 9
the skin: its getter at 0x14626, reading byte 2 of the /sys/sku record at internal 0x01F4C0; the three places that report it, 0x13216, 0x1389A and 0x0F258; the record writer at 0x15288, which nothing calls; the device descriptor, a constant at 0x1AC04. What they add up to, below 33

A held key

A key press ends in one of two events, and that is what a long press is on this image. A key raises its press when it goes down and starts a hold counter. Let go while the counter runs and the remote raises the release; keep the key down until the counter runs out and it raises a third event instead, after which no release follows22. The three are the event types of key codes: 0x80 the press, 0x40 the release, and 0xC0, which that table calls repeat and which here fires once and never repeats, so it is called the held event on this page22. So the firmware tells a short press from a long one by itself, for every key, and a configuration only chooses which of the two endings it binds.

what the 1.4 image does evidence
the hold parameter 0 times 100 ticks, one value for every key; a count of 1000 runs out on the 1001st tick and then stops 22
parameter 0 written by 0x3F with operand 0xF0nn, which sets it to nn; 0xF6nn and 0xF7nn set two others. The image starts it at 10, and every configuration of this family read sets 10 again at start, so the hold is 1001 ticks. A third writer sits in the USB service and was not followed 22, 23, 10
the tick the one the power on delay counts in, 100 ticks to each tenth of a second the delay waits, so by the delay measured on a unit 1001 ticks are about 1.005 s, where Logitech's guide says two seconds; the kind 0 timers of the timer table count the same tick 22, 24, 25
a select ends the hold 0x1F band 0xFF, which selects a key map, and bands 0xFE and 0xFD, which push and pop the map stack, clear the counter, so a press whose binding selects a map is followed by neither a release nor a held event 22

How each model's configurations use it is memory.md: a Harmony 350 binds a key's short press device to the release and a long press device to the held event. All of this is read in the Harmony 350's application. The Harmony 300's application is the same code at every routine named here, the comparison28. The Harmony 650's firmware raises the same three events with the same reload, 0x200 times 100, its keys; whether its counter also stops after the held event is not checked10.

The skin

The Harmony 350's 1.4 image reports the unit's skin and never acts on it. It reads one byte, tells the host, and has no branch on it that anything reaches33. So the keypad scan, the held event, the file write path and the configuration validator treat a remote that states skin 79 as they treat one that states 104, and the firmware caps nothing by skin: the limits this family states per skin, the README, are Logitech's service's and not the image's33.

what the image does evidence
where the skin comes from byte 2 of a 64 byte record in internal flash, the file table's /sys/sku row at 0x01F4C0, so 0x01F4C2; the getter is 0x14626. A unit's /sys/sysinfo states exactly that byte 33, 34
who reads it three places, each storing the byte into a reply and testing nothing: the skin field of /sys/sysinfo, a second builder of the same fields and one of the one byte replies of the reply dispatcher 33
the only branch on it a record writer at 0x15288 whose chain separates a blank record, skin 72 and skin 79 from the rest and sets a four byte value of the record to 2 for those two and 1 for the others. Nothing calls it: no transfer into its routines from outside, and no instruction or table anywhere in the image holds its address; the safe mode image holds the same routine and is as silent about it. A call through a pointer, which one helper at 0x19F1C makes, would not have been seen, and the pointers it jumps to were not enumerated10 33
the record's last bytes the value above, 2 on a skin 79 unit and 1 on a skin 104 one, and nothing read in the image fetches it 34
the check command on /sys/sku compares the record's first two bytes with the host's value and looks at nothing else 33
the board a nibble of PORTD, which /sys/sysinfo states as hw_ver, 0 on both models' units read, so the two boards do not differ there 33, 34
the configuration's own skin base slot 1 states it, the container, and the firmware never reads that slot: the section seeker loads slots 3 to 12 and the validator reads header offsets 0, 4 and 0x47 33, 18

What holds for a Harmony 300's application. This section was read in the Harmony 350's image, which is also what a Harmony 350 unit serves. The Harmony 300's is the same code but for the one routine, the comparison: the skin getter at 0x14626 and the record writer at 0x15288 sit in runs both images share, so the 300's are at 0x1461C and 0x1527E and instruction for instruction the same, and the one routine that differs, the send kind, does not read the skin28. So the statements above hold for a Harmony 300's application as read here, with its own /sys/sku record. The descriptor is where the two images differ and a skin shows: it is a constant in flash, copied to the endpoint buffer unchanged, whose bcdDevice is 0x1104 in the 350's image and 0x1078 in the 300's, which is why a Harmony 300 enumerates as 0x1078 whatever skin its record holds, its usb.md3328. Logitech's package names skins 78, 79 and 104 together, which is its word about the package and not a measurement of what a 300 runs1. Nothing in either image makes a configuration behave differently by skin3328.

Routines read in the bootloader and safe mode

Both images read off a Harmony 350, at the file table's addresses, with the PIC18F67J50 register map (the Harmony 300's two images are not these, below): the bootloader reaches ANCON0 and ANCON1 through the shadow bit of WDTCON and uses UCON at 0xF65, both that family's, both images program 64 bytes at a time, and safe mode erases 1 KiB pages. Which part exactly is not checked2010.

routine evidence
the bootloader's reset vector GOTO 0x0EFA; its start decision at 0x0700; the header test for HG at 0x001008, 0x0782; the keypad scan at 0x0360; the command switch at 0x01A8, the Harmony 600's 20
safe mode's entry 0x758E and start 0x520C; the request kept or cleared at 0x717C, 0x0F at 0x53BC, the install at 0x5424; the keypad scan at 0x6948 and the key switch at 0x527E; the application check at 0x53DE, with the header checksum at 0x3FE0 20

What validates the configuration

In the 1.4 image a remote keeps its judgement of the configuration in one bit and acts on the bit, not on the bytes: the configuration's verdict, bit 2 of data memory 0x68E, the same byte and bit the Harmony 700 uses1216. Six of the fourteen calls that seek a section of the configuration test the bit a few instructions before and skip the configuration when it is clear, and a seventh runs only after the validator has set it; whether the other seven are reached only with the bit set is not checked1210.

what sets or clears it evidence
at start the validator at 0x16090: GSPM at the start, LWJL at 0x47, PTYY at end_addr, then the trailer checksum, seeded 0x4321, over the little endian words from the start to the stored word at end_addr - 2, the container 12
the checksum's gate skipped while bit 0 of setting 0x80 in the settings store is clear, the gate the Harmony 600, 650 and 700 have; an absent setting reads 0xFF, so a store without one asks for the checksum 12, 17
a second call site in the main loop the same validator again, only if the verdict is clear; that this is the end of a USB session is likely and not checked 12
an open of /cfg/usercfg for writing clears it 12
the host's check answering m for /cfg/usercfg sets it, on the stored checksum word alone and without PTYY, usb.md 12

In the code read, a configuration that fails is not refused and does not stop the firmware. The validator returns with the verdict clear and an error code latched, 8 when a marker is missing and 4 when the checksum fails, which a routine at 0x1A7EE copies to 0x700 while setting four port pins, and the start goes on without loading the configuration's state12. What the code then does with those pins is below; how a unit behaves with a failing configuration is not checked10. There is no configuration to fall back on: /fw/embeddedcfg is a name in the firmware's pool that no row of the file table and no instruction points at, memory.md12.

The checksum as read reproduces the stored word of every configuration read off a Harmony 300 and a Harmony 350, five of them12.

Safe mode and recovery

Entering safe mode or the bootloader on this family destroys nothing, the opposite of the Harmony 525, whose safe mode copies itself over the application. The file table names the two images below the application, the bootloader, 4 KiB at internal 0x000000, and safe mode, 32 KiB at 0x0010004; both run at every start before it, and the only thing either writes on its own is an install the application asked for20. What follows about the two images is read in a Harmony 350's copies, on 1.4, since Logitech's package carries the application alone; a Harmony 300's two are different builds, compared below, and none of it has been done to a unit10.

What runs at a start

step what happens evidence
the bootloader scans the keypad: key 0x14 keeps it, as a USB programmer; key 0x2C runs safe mode at once; anything else runs safe mode if its header mark HG is at 0x001008, and keeps the programmer otherwise. It never runs the application and never reads the request byte below 20
safe mode, first keeps the request byte only after a restart by the RESET instruction and clears it after any other, a power on among them 20
a request of 0x0F the reboot with parameter 0x73: cleared, and safe mode stays for this one start 20
a request of 2 a firmware install's flush and close: safe mode installs the staged copy, below, and clears the request; 4, 6 and 7 do the same, and the 1.4 application sets none of them 20
a key held 0x03, 0x32 or 0x2C: safe mode stays 20
otherwise safe mode checks the application against the checksum in its header, seeds 0x21 and 0x43, and runs it at 0x900A when it matches; when it does not, safe mode stays 20

This page said the application's start clears that request only after a restart by the reset instruction, which read the branch the wrong way round: it keeps the request after exactly that restart and clears it after any other, which is how the request reaches safe mode13.

The install copies the staged copy and never safe mode. It reads the staged image's length at external 0x000004, adds 8 and caps it at 0x15C00, erases 1 KiB pages of internal flash from 0x009000 and copies the external bytes from 0x000000 over them, the arrangement the Harmony 600, 650 and 700 have, their firmware.md. It does not check the staged copy first: a bad one leaves a bad application, and then the check of the same start fails and the remote stays in safe mode, still on the cable. The cap keeps the erase below 0x01F400, the unit's own records20.

The keypad scan

Every key is a number from 1 to 56, and all three images number it the same way. The bootloader, safe mode and the application share one scan routine, literal for literal, apart from one key of the bootloader's three key restart2026. It pulls one of fourteen drive lines low at a time, PORTE bits 0 to 6, PORTA bits 3 to 5 and PORTD bits 0 to 3, reads four returns, PORTB bits 4 to 7, and numbers the key 4 * line + return, return counting from 1; 0 is no key.

The application hands that number to the key maps as it is, with an event type in the top two bits: 0x80 when a key goes down, 0x40 when it is let go or replaced by another, and 0xC0 once it has been held past a timer the press arms. A configuration's key map tag is therefore that type plus the code, and a tag below 0x40 is not a key: the firmware raises 0x26 to 0x28 and, from its send path, 0x2D to 0x30 through the same lookup26. Which key carries which code is each model's, the Harmony 350's keys.

code where what the start up images do with it the key, by the Harmony 350's table
0x14, 20 PORTE bit 4 with PORTB bit 7 the bootloader stays, as a USB programmer the digit 0
0x2C, 44 PORTD bit 0 with PORTB bit 7 the bootloader runs safe mode unchecked, and safe mode stays Play
0x03, 3 PORTE bit 0 with PORTB bit 6 safe mode stays Power
0x32, 50 PORTD bit 2 with PORTB bit 5 safe mode stays OK

The bootloader's two codes are the Harmony 600's, the bootloader20. The restart the scan tests first is codes 6, 53 and 51 held together in the application and safe mode, Watch TV, the digit 8 and the up direction key, and codes 6, 20 and 51 in the bootloader20. The key column rests on the Harmony 350's table, which is read and inferred from configurations, and none of it has been tried on a remote2710.

What each serves over USB

  • Safe mode answers the application's file protocol: the same device descriptor, 046D:C124 with release 0x1104, ten of the application's switch tables case for case, the control commands, device control and the check among them, and a file table of eleven rows. So the product id cannot tell the two apart; the product string can, Harmony Remote 4-1.4.0 in safe mode against the application's Harmony Remote 0-1.4.0, and /sys/sysinfo states fw_type 4, which Logitech's client calls safe mode2014. That every command behaves as the application's does is not checked10.
  • It can take a configuration and an application. /cfg/usercfg is readable and writable in its table, and /fw/normalmode is the resident application for reading and the staged copy for writing; a flush of the staged copy stores request 2 and its close reboots, so the next start installs it20. /fw/bootloader and /fw/safemode are writable rows there too.
  • The bootloader is the Microchip USB programmer of the Harmony One and the Harmony 600, 04D8:000B, with the Harmony 600's twelve commands and its erase that refuses anything below 0x001000, the bootloader. It writes internal flash only, and only when a host sends a write or an erase20.

Restoring a remote

A failed configuration write can be sent again over USB. The application starts, rejects a broken configuration, carries on without one and keeps answering on the cable: nothing in the USB service and the file commands it reaches reads the configuration's verdict, and the only two instructions there that touch it are the open for writing, which clears it, and a matching check, which sets it13. A write that stops with the power on leaves a file open, which the file system reset closes; one that stops with the power off leaves a configuration the start rejects, after which the remote runs on with no configuration and answers on the cable, usb.md13.

A damaged application is restored by safe mode, with the same seven commands as a configuration: a remote whose application fails its checksum stays in safe mode, a host writes the application to /fw/normalmode, flushes and closes, and the next start installs it20. That is Logitech's own route: its client calls an install required whenever a remote reports safe mode, and its firmware sequence for skin 104 is the configuration's seven commands, writing the package's image to /fw/normalmode with the reboot its manifest asks for1415. A damaged safe mode image is the bootloader's case: with no HG mark, or key 0x14 held, the remote stays in the programmer, which can rewrite internal flash above 0x00100020.

what the 1.4 application does evidence
a failing configuration latches an error code, 8 for a missing marker and 4 for the checksum, which stands until the processor restarts, and switches four output pins on and off in a pattern counted from it, from the main loop. It neither stops nor restarts. That the pins are the remote's lights is not checked 13, 10
the firmware type /sys/sysinfo states always 0, a constant in the code; safe mode's is 4 13, 20
a request for the next start a byte in data memory, 0x0F from the reboot command's parameter 0x73 and 2 from a flush of /fw/normalmode open for writing, whose close then restarts; safe mode acts on both, above 13, 20
three keys held together restart the processor, tested at the start of the keypad routine; safe mode tests the same three and the bootloader swaps one for key 0x14. By the Harmony 350's key table they are Watch TV, the digit 8 and the up direction key, above, which has not been tried 13, 20, 27, 10
a way into the images below it none: no call or jump in the application targets an address below 0x9000, and its three reset instructions restart the processor with nothing written on the way, which runs the bootloader and then safe mode 13
  • A configuration write cannot damage the firmware. Its erase runs from 0x020000 to 0x07FFFF, the staged copy ends below 0x020000, and nothing in it reaches the processor's own flash, where the application, the safe mode image and the bootloader live13.
  • An internal image is served eight bytes short. The application states the size of /fw/safemode and /fw/normalmode for reading as the image header's length field, which is the length less 8, so a read ends eight bytes before the image does: 26040 bytes of a 26048 byte safe mode image2120. Those eight bytes hold a routine safe mode's start calls, which is therefore not read10. The check command tests the HG header in both internal images, so a remote can verify them without a read13.

The two models' bootloaders and safe mode images

They are different builds, and the safe mode images are different versions. Read off a Harmony 300 and off a Harmony 350, with the PIC18F67J50 register map29:

Harmony 300 Harmony 350
safe mode version, from the header's byte 7 and the product string 1.2, Harmony Remote 4-1.2.0 1.4, Harmony Remote 4-1.4.0
safe mode length stated, served 25408, 25400 26048, 26040
safe mode entry point 0x72D2 0x758E
safe mode bcdDevice, at 0x102A 0x1078 0x1104
  • The two safe mode images differ in version as well as in model, so which of what follows is the model's and which the version's cannot be told from these two28. With RAM addresses, literals and branch targets masked their listings differ in 24 stretches. The larger ones: a block of 709 instructions that sits 0xF46 lower in the Harmony 350's image than in the Harmony 300's, a stretch of 181 instructions, 408 bytes, at 0x3B52 in the Harmony 350's that the Harmony 300's has no counterpart of, and a block of state in bank 14 in the Harmony 350's that holds 15000 and 1000 and compares a sum with 100028. What the added code does, and whether any of it is in the file protocol that carries a configuration, is not read10.
  • The bootloaders differ in 1998 of 4096 bytes. Their start decision is the same and the rest of the build is not: the keys 0x14 and 0x2C and the test for HG are in both; one key of the restart combination differs, the Harmony 300's scan testing PORTD bit 3 with PORTB bit 4, code 53, as the application does, where the Harmony 350's tests PORTE bit 4 with PORTB bit 7, code 20; the Harmony 350's has a byte exchange on the second serial port, SSP2, at 0x0E6C that the Harmony 300's has no counterpart of, the Harmony 300's only switching that port off; the two set up their ports and oscillator with different values; and the Harmony 300's start code makes PORTB bit 3 an output where the Harmony 350's makes PORTG bit 0 one and drives it as a counted pattern28. What those pins are wired to is not read10.
  • Neither runs a configuration. The application interprets a configuration's action lists and these two do not, so a difference in them cannot change what a configuration does once the application runs; whether one changes how a configuration is written to a unit in safe mode is not read10.

Not checked

  • Which image Logitech's service serves a Harmony 300 when asked by skin 78 or 79: the package fetched was the one for skin 104, and the Harmony 300 read runs a different build of the same version10.
  • Which of the two applications is the later build: both say 1.4, and the Harmony 350's carries the mask10.
  • That a Harmony 300 of the other printing, skin 78, runs the build a skin 79 unit does10.
  • Which version a given remote runs: its /sys/sysinfo carries a version field, and only the product string's 1.4.0 has been read11.
  • What a Harmony 300's bootloader and safe mode image do beyond how they differ from the Harmony 350's, and any build of either but the two read; that the four start codes and the restart are the keys the Harmony 350's table names; and the eight bytes at the end of the safe mode image that a read does not return10.
  • Whether a configuration that passes the validator and hangs while its state is loaded at start would keep a remote from the USB service, and whether the processor's watchdog is on, which is in the configuration words at internal 0x01FFF810.
  • What a failed validation shows a person, and whether a configuration the check marked good is put to use before the remote restarts, since the check sets the verdict without the loading the start does10.
  • Whether a unit's settings store holds setting 0x80, and so whether its start checks the checksum10.

  1. Stated by Logitech, by their service. Section 196 ↩↩↩↩↩

  2. Stated by Logitech, in their client. MyHarmony's version list ↩

  3. Read in the firmware. Section 196 ↩↩

  4. Read in the firmware. Section 199 ↩↩↩

  5. Stated by Logitech, in their client. Section 295 ↩

  6. Read in the firmware. Section 259 ↩↩

  7. Read in the firmware. The test ↩

  8. Read in the firmware. Section 322 ↩

  9. Read in the firmware. Section 276 ↩

  10. Not checked. ↩↩↩↩↩↩↩↩↩↩↩↩↩↩↩↩↩↩↩↩↩↩↩

  11. Measured on a unit. Section 193 ↩

  12. Read in the firmware. The test ↩↩↩↩↩↩↩↩↩↩↩↩↩

  13. Read in the firmware. The test ↩↩↩↩↩↩↩↩↩↩

  14. Stated by Logitech, in their client. The test ↩↩

  15. Stated by Logitech, by their service. The test ↩

  16. Read in the firmware. Section 310 ↩

  17. Read in the firmware. Section 354 ↩

  18. Read in the firmware. The test ↩↩

  19. Read in the firmware. The test ↩

  20. Read in the firmware. The test ↩↩↩↩↩↩↩↩↩↩↩↩↩↩↩↩↩↩↩↩↩↩↩

  21. Measured on a unit. The test ↩

  22. Read in the firmware. The test ↩↩↩↩↩↩↩

  23. Measured in configurations. The test ↩

  24. Measured on a unit. The test ↩

  25. Stated by Logitech, in the manual. The Harmony 350 setup guide ↩

  26. Read in the firmware. The test ↩↩↩

  27. Measured in configurations. The test ↩↩

  28. Read in the firmware. The test ↩↩↩↩↩↩↩↩↩↩

  29. Measured on a unit. The test ↩↩↩↩↩

  30. Read in the firmware. The test ↩↩↩↩

  31. Measured on a unit. The test ↩↩

  32. Measured in configurations. The test ↩↩↩

  33. Read in the firmware. The test ↩↩↩↩↩↩↩↩↩↩↩

  34. Measured on a unit. The test ↩↩↩