Skip to content

Harmony 525: memory

The layout is the architecture's, read on this model: the address windows, the external flash with the safe mode image at 0x800000, the application at 0x810000 and the configuration from 0x820000, the 32 KiB of internal flash and the 256 bytes of EEPROM, the architecture's memory.md. This page carries what a reader of the 525 needs first, and what its configurations hold.

The three facts to carry

  • The application is one erase block below the configuration: 0x810000 against 0x820000, in 64 KiB blocks,12 and the firmware refuses an erase of neither.3
  • There are two address spaces: a command names 0x820000, and the container's own pointers count from 0x020000.1
  • No memory read of a running remote is known: the data memory window answers zeros,4 and READ_MISC serves selector 1 alone,5 so nothing about the clock, the keypad or the validation flags is measured.

What the configurations hold

value
infrared class 5 in every record, a dictionary of pulse blocks, infrared records6
bound key codes fifty, 1 to 57 with no multiple of eight, keys.md7
state variables the firmware owns 0 to 12;8 the clock is the first seven9
size a configuration fits one 64 KiB erase block with its trailer checksum, so the whole container sits in the block at 0x8200002
the space above it can hold the tail of an earlier configuration, since flash is erased only where a write needs room10

Not checked

  • Whether the state variable storage is painted 0xFE above its declared size at every boot, which is read on the other architectures and not on this one.11
  • What the remote keeps in data memory while it runs: no read reaches it.12

  1. Measured on a unit. Section 76 ↩↩

  2. Measured on a unit. Section 269 ↩↩

  3. Read in the firmware. Section 267 ↩

  4. Measured on a unit. Section 137 ↩

  5. Read in the firmware. Section 90 ↩

  6. Read in the firmware. Section 82 ↩

  7. Measured in configurations. Section 89 ↩

  8. Read in the firmware. Section 284 ↩

  9. Read in the firmware. Section 274 ↩

  10. Measured on a unit. Section 270 ↩

  11. Read in the firmware. Section 276 ↩

  12. Not checked. ↩