A remote of this platform talks to a computer the way the Harmony One and the Harmony 600, 650 and 700 do: it shows up as a vendor specific HID device and answers short commands, read this, erase that, write this. The commands are the same family and fewer of them are implemented, and two things a host can do on the later remotes are missing here, reading the processor's working memory and restarting the remote.

The command protocol is the USB protocol reference and the rails are packages/usb/src/rails.ts. This file states what holds on this architecture, measured on a Harmony 525, with the Harmony 515's identity beside it where a bullet names that model; the other models are not checked.1

Identity

field value from
USB product id 0xC111 PROFILES in packages/remote/src/read.ts
flash top bytes accepted 0x80 to 0x87, so external flash is 0x800000 to 0x880000 ARCH9_FLASH_TOP_MIN and ARCH9_FLASH_TOP_MAX in packages/usb/src/protocol.ts
the other windows 0x00 internal-program-memory below 0x8000, 0x20 eeprom below 0x0100, 0x30 arch9-tag-30 below 0x0008, 0x40 data-memory below 0x0800 ARCH9_WINDOWS in packages/usb/src/protocol.ts
escape sub commands dispatched none read ESCAPE_SUB_COMMANDS in packages/usb/src/protocol.ts

Generated from packages/remote and packages/usb by make remote-reference-write. Change the source, not this block.

  • bcdDevice is 0x0916: the protocol number 9 and the skin 22 as plain hex, where the Harmony One and the Harmony 600, 650 and 700 carry BCD of 1000 + skin. So that rule is the later generation's, and the transport has both forms.24 A Harmony 515 enumerates 0x0943, skin 67 by the same rule, which a configuration read off it states as well.3
  • The version block is seven fields, and the reply byte's low nibble says so: 27 30 25 12 ff 90 16 09 is firmware 3.0, board 2.5, flash FF:12, architecture 9 with software type 0, skin 22 and a platform byte of 0x09. A host that expects twelve fields refuses a correct answer twice.2 A Harmony 515's fields, without the reply byte, are 34 10 12 ff 90 43 09: firmware 3.4, board 1.0, the same flash, skin 67 and the same platform byte. Its product string is Harmony Remote 0-3.4.0.3
  • In safe mode the block is 20 25 12 ff 94 16 00, firmware 2.0, software type 4 and a platform byte of zero; the product string becomes Harmony Safe Mode!; and the HID report descriptor differs in one input flag. The product id and bcdDevice do not change, so enumeration cannot tell the two apart.5
  • The unit identity is in EEPROM, protocol address 0x200010, not at the Harmony One's internal 0xFF +0xF400, which this architecture refuses as an address; IDENTITY_ADDRESS in packages/usb.6

Commands

Seven in the application's dispatch, decoded from its chain:7

byte command
0x10 GET_VERSION
0x30 WRITE_FLASH
0x50 READ_FLASH
0x70 START_IRCAP, the learn capture; 0x80 stops it8
0xA0 WRITE_MISC
0xB0 READ_MISC
0xD0 ERASE_FLASH
  • Reads work across the windows of memory.md: internal flash, EEPROM and the serial flash answer content.9 The data memory window answers zeros whatever it holds.10
  • The first exchange after connecting can go unanswered, and a single retry covers it; no reset is needed.2
  • ERASE_FLASH is a general flash erase whose window the address chooses: an address with top byte 0x00 erases the running firmware's own internal program flash, one in the EEPROM window does nothing and reports success, and one in the serial flash window erases a 64 KiB block of the part. The firmware bounds that last arm by the part and nowhere finer, so all eight blocks are reachable, both firmware images among them. On the Harmony One the remote refuses part of that range itself; here nothing in the remote does, firmware.md.7

READ_MISC, and why there is no live memory read

On the Harmony One and the Harmony 600, 650 and 700, READ_MISC selector 7 reads a byte of the running remote's data memory, which is how a host watches the keypad or the clock. On this platform the executor serves selector 1 and nothing else. It emits the reply code 0xC2, echoes the selector, clears its two result bytes, and only then tests the selector; every selector but 1 skips the body and sends the two bytes it has just cleared.11

Selector 1 returns a parameter by index. The reply is C2, the selector, the high byte and then the low byte. Below index 0x1A0 the parameter is one byte fetched through INDF0 and the high byte is always zero; at 0x1A0 and above it is two bytes, with a real high half.11

A decoder that takes the first byte after the selector as the value reads zero for every byte sized parameter, since that byte is the high half. Selectors 0, 1, 2, 4, 5, 6, 7, 8 and 12 all answer zero read that way, which says nothing about selector 1.12 What selector 1 answers on a running remote, decoded high byte first, has not been read; a third party has reported index 0 moving with the clock and the first seven words decoding to a date and time.1

So the data memory read and the battery reading the later remotes serve do not exist here, and with the data memory window answering zeros too, no read path to this platform's working memory is known. Whether selector 1's index reaches anything beyond its parameters is not checked.1

Write standing

path open on this architecture list
erase and write a configuration block yes ARCHITECTURES_WITH_A_WRITE_TARGET
drop the cached region descriptors, WRITE_MISC 0x02 yes ARCHITECTURES_WITH_AN_INVALIDATE_TARGET
restart, the escape's 0x02 no ARCHITECTURES_WITH_A_RESET_TARGET
write a byte of data memory, WRITE_MISC 0x07 no ARCHITECTURES_WITH_A_RAM_WRITE_TARGET
append to the settings store no ARCHITECTURES_WITH_A_SETTINGS_WRITE_TARGET, SETTINGS_WRITE_READ_ON
ask safe mode to install the staged firmware no ARCHITECTURES_WITH_A_REINSTALL_TARGET, REINSTALL_MAX_IMAGE, STATUS_BYTE_READ_ON_APPLICATION

Every row also needs HARMONY_ENABLE_WRITES=1, its own named door where it has one, and the unit check on the identity block. Which unit may be written is not in this table and cannot be: an architecture names a kind of remote, and the unit check compares the identity block read off the remote with a record of a permitted unit kept outside this repository.

Generated from packages/usb/src/rails.ts by make remote-reference-write. Change the source, not this block.

Why this library's rail is the whole protection here: the configuration begins at 0x820000, the stored application sits in the block below it at 0x810000, the safe mode image below that, and the firmware refuses none of them.7 So assertEraseAllowed requires a block aligned address and a whole block between CONFIG_REGION_BASE and WRITABLE_CEILING, and the ceiling stops below the log area at 0x870000 rather than at the part's end,13 packages/usb/src/rails.ts.

What a write does here that it does not do on the Harmony One: nothing restarts, since the configuration is not executed in place, and nothing needs re-checking, since this platform re-validates only when asked.1415 A configuration of a 525 fits inside one 64 KiB block with its trailer checksum, so reading a written block back covers the whole configuration.15

What is refused on this architecture and why: the restart, because the escape dispatcher has not been read; the data memory write, because its executor has not been read and the part's register page sits where the bound would pass an address that is neither memory nor a register;16 the settings store and the firmware reinstall, which are read on the Harmony 600, 650 and 700 only.17

Not checked

  • WRITE_MISC and the escape on this image, beyond what the dispatch shows.1
  • What selector 1 of READ_MISC answers, decoded correctly, on a running remote.1
  • Erasing and writing any block of the configuration region but 0x820000.1
  • Every model of this architecture but the Harmony 525, beyond the Harmony 515's identity.1

  1. Not checked. ↩↩↩↩↩↩↩

  2. Measured on a unit. Section 76 ↩↩↩

  3. Measured on a unit. The test ↩↩

  4. Measured on a unit. Section 195 ↩

  5. Measured on a unit. Section 118 ↩

  6. Measured on a unit. Section 268 ↩

  7. Read in the firmware. Section 267 ↩↩↩

  8. Read in the firmware. Section 123 ↩

  9. Measured on a unit. Section 119 ↩

  10. Measured on a unit. Section 137 ↩

  11. Read in the firmware. Section 90 ↩↩

  12. Measured on a unit. Section 90 ↩

  13. Measured in configurations. Section 47 ↩

  14. Read in the firmware. Section 253 ↩

  15. Measured on a unit. Section 269 ↩↩

  16. Read in the firmware. Section 269 ↩

  17. Read in the firmware. Section 295 ↩