Harmony 600, 650 and 700: USB¶
A computer talks to these remotes over USB in short reports of 64 bytes: it asks for the version, reads
and writes flash, and reads a few things the running remote holds. The command protocol is
the USB protocol reference and the rails that refuse writes are
packages/usb/src/rails.ts. This file states what holds for all three models and links there for the
rest.
Identity¶
| field | value | from |
|---|---|---|
| USB product id | 0xC122 | PROFILES in packages/remote/src/read.ts |
| first refused flash top byte | 0x20, so external flash ends at 0x200000 | FLASH_TOP_BYTE_BOUND in packages/usb/src/protocol.ts |
| escape sub commands dispatched | 0x01, 0x02, 0x03, 0x05 | ESCAPE_SUB_COMMANDS in packages/usb/src/protocol.ts |
Generated from packages/remote and packages/usb by make remote-reference-write. Change the source, not this block.
- One product id for three models, measured on all three. Nothing on the bus separates them but the skin in the version block and, per remote, the identity block12.
bcdDeviceis BCD of 1000 plus the skin, measured on a 600 as0x1071, the transport3. The 650's 0.2 build carries0x1072in its device descriptor4; on the 650's bus and on the 700 it is not checked5.- The model number in the version reply is the build's own constant: 71 in the 600's 0.2 and 72 in the 650's4.
- The version block's twelve bytes: firmware, hardware, flash id, architecture in field 4's high nibble, skin and platform, the version block6.
- Safe mode answers as software type 4, the application as 07.
Commands¶
The same seven commands as every image, the command table, with handler addresses given for the 600's 0.2 and the 700's 2.8. Two additions are this architecture's alone:
0x10with a payload is a second command family, below: its first payload byte selects a state,0xB2reads a setting,0xB3writes the settings store,0xB1any byte of data memory and0xBDa word of program memory8. Only0x10bare and0x13 0xB2pass the read only allow list; the write is behind its own rail,assertSettingsWriteAllowed, and has been sent to a Harmony 600 only9.- The escape dispatches a sub command
0x05that the Harmony One's does not,ESCAPE_SUB_COMMANDS.
Live data memory reads, READ_MISC selector 7, work on this architecture, measured on a 65010,
and the state variables read on the cable are live on all three: on a 600 its delays, its running clock
and the Off screen's mark1112, and on a 700 its clock13. An earlier reading that a 600 on
the cable had not loaded its configuration read five journal variables, another kind14, and is not
a reason to distrust such a read12.
The battery voltage can be read over USB, READ_MISC selector 0x0C detail 1: two bytes, high byte
first, in millivolts, measured under load and so a little below what a meter shows on the cells15.
The firmware implements it on the 600 and 700 images and on the 650's build1617; it has been
sent to a 650 only, and the 600 and 700 have not been asked5. Logitech's client offers the
reading for the Harmony One alone, so on these three models it is not a product feature18. Detail 0
is one byte from a fixed data memory address; any other detail answers whatever the previous command left
behind, which is why packages/usb refuses it16.
Write standing¶
| path | open on this architecture | list |
|---|---|---|
| erase and write a configuration block | yes | ARCHITECTURES_WITH_A_WRITE_TARGET |
drop the cached region descriptors, WRITE_MISC 0x02 |
yes | ARCHITECTURES_WITH_AN_INVALIDATE_TARGET |
| restart, the escape's 0x02 | yes | ARCHITECTURES_WITH_A_RESET_TARGET |
write a byte of data memory, WRITE_MISC 0x07 |
no | ARCHITECTURES_WITH_A_RAM_WRITE_TARGET |
| append to the settings store | yes, on builds 0.2 | ARCHITECTURES_WITH_A_SETTINGS_WRITE_TARGET, SETTINGS_WRITE_READ_ON |
| ask safe mode to install the staged firmware | yes, at most 89088 bytes; from a running application on builds 2.5, 2.8 | ARCHITECTURES_WITH_A_REINSTALL_TARGET, REINSTALL_MAX_IMAGE, STATUS_BYTE_READ_ON_APPLICATION |
Every row also needs HARMONY_ENABLE_WRITES=1, its own named door where it has one, and the unit check on the identity block. Which unit may be written is not in this table and cannot be: an architecture names a kind of remote, and the unit check compares the identity block read off the remote with a record of a permitted unit kept outside this repository.
Generated from packages/usb/src/rails.ts by make remote-reference-write. Change the source, not this block.
Builds: the configuration writer refuses a commit on a build whose cache drop and restart have not
been read: 0.2 on the 600 and 650, 2.8 on the 700, packages/remote/bin/write-config.ts1920.
What a write does here that it does not do on the Harmony One: the cache drop arms the next erase, and
an erase at exactly 0x030000 then may update setting 0x80 in the settings store, which on both
remotes read would write nothing19. And the remote does not execute its configuration in place: a
650's first write, an erase and a write with no restart sent, left it on the bus1.
Not checked¶
bcdDeviceas the bus reports it on the 650 and 7005.- The settings read and write on the 650 and 7005.
- The data memory, program memory and action queue members of the
0x1Nfamily, read and never sent5.
0x10 with a payload is a second command family, arch 14 only¶
GET_VERSION is the bare 0x10. On the Harmony 600, 650 and 700 a nonzero length nibble turns it
into something else: the first payload byte becomes the command state when it lies in 0x10 to 0x35
or 0xA0 to 0xC5, and on the 700's 2.8 also 0xD0 to 0xD6. Twenty of those states have an argument
parser and 54 an executor8. Read so far:
| request | what it does | evidence |
|---|---|---|
0x13 0xB2 hi lo |
read setting lo of the settings store, the latest record winning |
8 |
0x14 0xB3 hi lo value |
write it, appending a record to the two 1 KiB blocks from internal 0x01EC00 |
8 |
0x14 0xB1 hi lo byte |
write a byte anywhere in data memory, twelve bits of address, at parse time and unchecked | 8 |
0x13 0xB0 hi lo |
read a byte of data memory | 8 |
0x12 0xB9 byte |
write the byte to data memory 0x200 |
8 |
0x11 0xBD |
program 0xFFFE into internal 0x01F6C0 when that word's bit 0 is set |
8 |
0x14 0x34 opcode hi lo |
push the action instruction opcode with operand hi lo onto the forty slot action queue, at parse time, through the push the configuration's own instructions take; on the 600 and 650 0.2, the 650 0.4 and the 700 2.5 and 2.8; read and never sent |
21 |
hi must be 0 for 0xB2 and 0xB3: both store routines refuse a setting of 0xFF or more8. A
settings read answers seven bytes, 0xF0 0x11 0xB2 0x01 0x01 0x01 value, measured on a Harmony 600
with all 41 delay settings agreeing with a whole read of its store; the fourth byte is 4 for a command
that clears the firmware's flag, and 0xF0 0x0E answers a byte outside the ranges22. A settings
write answers 0xF0 0x11 0xB3 0x01 0x01 0x01 0x00 on success, measured on a Harmony 600 with four
writes23; a failure answers 4 in the fourth byte and the append's code in the seventh, 5 for a
setting of 0xFF or more, 6 for no active block, 7 for a read back mismatch, and 4 for a full store only
after the firmware has copied it, then erased and formatted both blocks, and still found no room. A write
carrying the value the setting holds writes nothing and answers success, and so does a write onto the
block's last record, which the firmware follows with a copy and an erase9. It reaches a remote only
through HarmonyRemote.writeSettings, behind HARMONY_ENABLE_WRITES=1 and HARMONY_SETTINGS_WRITE=1.
The Harmony One's handler reads no payload. The transport's allow list passes 0x10 bare and the
settings read 0x13 0xB2, and nothing else in the family, because keying on the high nibble had let
0xB3, 0xB1 and 0xBD through as reads8. Most of the other states are unread5.
-
Measured on a unit. Section 281 ↩↩
-
Measured on a unit. Section 295 ↩
-
Measured on a unit. Section 302 ↩
-
Read in the firmware. Section 392 ↩↩
-
Read in the firmware. Section 57 ↩
-
Read in the firmware. Section 87 ↩
-
Read in the firmware. Section 305 ↩↩
-
Measured on a unit. Section 283 ↩
-
Measured on a unit. Section 303 ↩
-
Measured on a unit. Section 387 ↩↩
-
Measured on a unit. Section 386 ↩
-
Measured on a unit. Section 110 ↩
-
Measured on a unit. Section 340 ↩
-
Read in the firmware. Section 212 ↩↩
-
Read in the firmware. Section 340 ↩
-
Stated by Logitech, in their client. Section 212 ↩
-
Read in the firmware. Section 282 ↩↩
-
Read in the firmware. Section 299 ↩
-
Read in the firmware. Section 326 ↩
-
Measured on a unit. Section 304 ↩
-
Measured on a unit. Section 305 ↩