Harmony Touch: memory¶
No memory has been read off a Touch, and there is no address a host can name. A host opens a path and the remote decides what is behind it1. What is known is which paths open, from nineteen probed on one remote23.
The paths that open¶
| path | stated size | what it is | evidence |
|---|---|---|---|
/sys/sysinfo |
234 bytes | fourteen lines of a name and a value: architecture, skin, firmware version and type, hardware version, the USB link, ram_size, status, feature, a serial |
2, 3. On the Harmony 300 and 350 the same path is generated on request rather than stored4; on the Touch not checked9 |
/rf/deviceinfo |
83 bytes | the word Response, a comma and a JSON object: a radio identity, a list of paired devices and their count. A query answered when opened, not storage |
3 |
/tde/enable |
1 byte | not read | 2 |
/fw/otaupdate, /ir/ir_cap |
0 bytes | not read | 2 |
/sys/hlapi |
0 bytes | the remote's request and answer file: a request is written into it and the answer read back, which is how Logitech's client syncs the remote in both directions, usb.md, and how this project's answerer syncs it in Logitech's place, answering a sync. It opened at 0 bytes when probed outside a sync | 2, 5, 6, 7 |
/sys/time |
0 bytes | Logitech's client writes the time and a time zone into it during a sync down, and in both syncs down measured the remote refused the write; a hand over of the remote's changes wrote nothing to it; not read | 2, 5, 6 |
/sys/factoryreset, /sys/reboot |
0 bytes | controls that act on a write and do nothing when opened; neither is on the inert list, usb.md. This row said opening one is the action until the native program was read, the names | 2, 12 |
Two files on one remote are two formats, lines of text and JSON, so a reader must not assume a shape,
and the field set of /sys/sysinfo differs from the list in the Harmony 300 and 350's firmware2.
The configuration is not a file a host can open¶
On the remote it is a set of documents in the remote's own store, not a path on the cable8. Where each document is kept, and the index beside them, is the platform's favourites, settings and pictures; what the documents hold is the platform's pages.
/cfg/usercfg does not exist on a Touch, nor do five other spellings, so the Harmony 300 and 350's
configuration path does not transfer2. That fits Logitech's own template, which carries the read of a
user configuration commented out "for testing only"10, and the provisioning route, by which the remote
fetches its configuration itself11.
The Harmony 300 and 350's file table, read out of their firmware, is that family's and does not transfer either: this is a later generation4.
Not checked¶
- What
/tde/enableis, and what/sys/timeanswers when read9. - Whether any path a host can open reads a stored document back without the named door9.
- The flash and RAM sizes9.
-
Measured on a unit. Section 198 ↩
-
Measured on a unit. Section 201 ↩↩↩
-
Read in the firmware. Section 199 ↩↩
-
Stated by Logitech, in their client. Section 198 ↩
-
Stated by Logitech, in their client. Section 203 ↩