Skip to content

1. Summary

The firmware is PIC18 machine code and it is directly disassemblable. The reason this had not been established is that concordance --dump-firmware does not return usable code on either architecture here, for two different reasons. It does on arch 8 and arch 9, which is section 2's correction of 8 August 2026 and is not a detail: it is the route to an image for a model this project has no hardware for.

  • Arch 12 (Harmony One). The dump contains no code at all. It returns a small GSPM config container instead. The application lives at flash 0x020000, which concordance never reads.
  • Arch 14 (Harmony 600/700). The dump is real PIC18 code, but it is silently truncated. The firmware image is 70336 bytes on the 600 and 76672 bytes on the 700, while FIRMWARE_MAX_SIZE is 65536. The missing tail contains the entry point.

Load addresses, determined empirically and cross-validated:

Image Size Execution base Entry point
Harmony One 3.4 60050 (0xEA92) 0x020000 0x02EA38
Harmony 600 0.2 70336 (0x112C0) 0x009000 0x01A26E
Harmony 700 2.8 76672 (0x12B80) 0x009000 0x01BB38

the archive | section 2. Section 1 of the findings archive, which is frozen; the reference holds the current answer. The archive on GitHub.