111. Two open items measured on a Harmony One, which turns out to be running while it is read¶
A Harmony One is on the bench, so section 103's display light band and section 47's log area can both be read. Section 103's three outcomes were committed when it was written; the rest go here, before anything is read, and section 110 sharpens all of them: a remote on USB has not loaded its config, so anything a config states is not in RAM. (That premise is what the measurement below refutes, and these predictions are left exactly as they were committed.)
The predictions¶
- Which unit it is. Two Harmony Ones enumerate identically, so the unit is identified by which
lab dump a read at
0x040000matches, never by the product id. A 256 byte read matches exactly one of the four arch 12 dumps byte for byte, and that is the health check as well. 0x110, the display light's band: zero. Section 103 offered three outcomes and called 2 and 3 the likely ones. Section 110 makes it outcome 3 rather than a guess: the band is computed by comparing a measured sum against base slot 15 group 4's three threshold pairs, and no config is loaded, so there are no thresholds.0x112, the saved state, and0x113, the cached level, should be zero for the same reason.0x111, the battery gauge: zero too, and this is the one worth being wrong about. Its eight levels come from groups 5 and 6, which are equally absent, so a nonzero value would mean the sampler runs on USB with thresholds from somewhere other than the config, and that would be a finding rather than a footnote.0x3FFFF0, sixteen bytes of flash: erased. Section 47 left this as the one thing it could not say about the arch 12 log area. No config in the corpus emits any of the five append opcodes, so nothing has ever written there, exactly as the 600's journal turned out in section 109.0x01F580over USB:0xFF. The control for the dual address hazard section 105 recorded. A firmwareTBLRDat that number reads the on chip page0xFF, where both units' battery calibration words live and neither is0xFF; aREAD_FLASHat the same number over USB reads the external part. If the window is not erased the hazard is worse than recorded, because the two memories would both be plausible and nothing would flag which was answered.
What would falsify rather than inform. If the unit's config does not match a dump, nothing else in this section can be trusted and the read stops there.
What the remote said¶
Measured on 10 August 2026, one session, every read through packages/usb and every one of them a
read. The predictions above went in as commit cd0a81a before the cable went in.
1. The unit is the spare, and the test that should have said so could not. The version reply is
34 05 c8 1f c0 36 0c 34 34 16 34 34, and 32 bytes at 0x040000 are
47 53 50 4d e0 3d 18 00 00 16 00 00 0b 24 06 00 ..., byte for byte one_spare_after_sync. The
gated hardware test reported "the read matches none of the stored dumps", and the fault was in the
test: BENCH's dump list named one_config and one_config_unprogrammed and neither of the spare's
two dumps, so the test whose whole job is to identify a unit could not identify half the bench.
Corrected in the same commit as this section.
2 and 3. Both wrong, and how they are wrong is the finding. The four bytes read 01 07 03 14,
identical on a second read:
| address | what section 103 calls it | predicted | measured |
|---|---|---|---|
0x110 |
the band, four levels from group 4's thresholds | 0 | 1 |
0x111 |
the battery gauge, eight levels from group 5 or 6 | 0 | 7 |
0x112 |
the saved state | 0 | 3 |
0x113 |
the cached light level | 0 | 20 |
They are not arbitrary and they are not compiled in defaults. 0x110 is band 1; section 103's state
6 maps band 0 to 3 onto states 2 to 5, so band 1 is state 3, and 0x112 is 3. Base slot 15 group
1's entries 2 to 5 are the four levels and this config's are 20, 20, 26, 26, so band 1's level is
entry 3, which is 20, and 0x113 is 20. The firmware's own defaults are 9, 16, 24, 27 and contain
no 20 at all. So three data memory bytes agree with each other through a table that only the config
states, which is the independent closure this project's standard asks for and it is the opposite of
what prediction 2 said.
A second subsystem says the same by a different route. LATC reads 0x37, so bit 5 is set, and
section 106 reads that pin as the enable of the I2C device at address 0x60 and says the firmware
never sets it: only a config does, through 0x3F band 0xC0 selector 16.
Section 103's outcome 2, and with a liveness control in the same poll. 357 rounds over 60 seconds, reading the converter and the four bytes and the clock's seconds together:
| watched | distinct values in 60 s |
|---|---|
ADCON0 |
1, and it is 0x00, so the converter is off |
ADRESH:ADRESL |
1, and it is 0x03C6, 966 of 1023 |
0x110, 0x111, 0x112, 0x113 |
1 each |
0x108, the clock's seconds |
15 |
So the analogue sampler does not run while the remote is on USB, and the remote is not idle either.
That is outcome 2 rather than outcome 3, and outcome 1 is excluded by measurement rather than by
assumption: covering the sensor cannot move a band nothing is recomputing. 966 of 1023 is also what a
charging battery reads, which is 0x111 being 7 of 8, so the last conversion this remote performed
agrees with the level cached beside it.
What FreeHarmony needs out of that is one sentence: on a connected Harmony One the display light band is readable and stale, so an interface may show it and must not present it as live.
4. A remote on USB runs its application, and the phrase this project has been repeating is wrong. Section 48 concluded "a remote on USB never runs its application, so the keypad handler never runs", and section 99 had already contradicted the first half without either being reconciled: mode 1 is USB mode, a mode of the application's own loop, with a body that polls and an exit gate. The measurement settles it four ways:
T1CONis0x1F, which is the0x1Ebase slot 3's routine writes plusTMR1ON, so the config's clock was started and is running;TMR1H:TMR1Ladvanced0x1FE4,0x202C,0x2195across three rounds of nine reads;UCONis0x08,USBENset, which is the positive control that the reads land at all;- of 256 data memory bytes from
0x100, exactly one moved in twenty seconds, and it moved by 20.
Section 48's real finding is the narrower one it also states, and that one stands: the keypad handler never runs, because USB mode's body does not scan the matrix. What does not stand is "the application". The four places that had copied the broad wording are swept.
The special function registers answer on arch 12, which is worth recording on its own, because on
arch 9 they read back zero and that difference decided a measurement, section 89. PORTA 0x29,
PORTC 0xB8, LATC 0x37, WDTCON 0xC1, ADCON1 0x86. So the whole register file of a
connected One is observable, and that is a bench capability nobody had established.
5. The one byte that moved is a clock, and all seven of its fields are named. 0x108 advanced
0x27 to 0x3B in twenty seconds. The firmware says what it is, at 0x27A0E:
27a0e: MOVF 0x34,B,W ; the elapsed whole seconds
27a12: ADDWF 0x108,F ; into the seconds field
27a14: MOVLW 0x3c ; 60
27a18: SUBWF 0x108,W
27a1a: BNC 0x27a2c ; under a minute: done
27a1c: CALL 0x20072 ; a once a minute routine, and not the minute itself
27a24: SUBWF 0x108,F ; subtract 60
27a28: BSF 0xf31,1 ; and flag that the minute changed
27a2a: BRA 0x27a14 ; while it is still 60 or more
Where the minute is incremented is not located, and this section said 0x20072 first. That routine
reads PORTA bit 4 and UCON bit 3, so it is charger and USB housekeeping that happens to run once a
minute; the increment is somewhere below it or in one of its callees. Neither pic18_trace nor an
image wide scan finds a direct write to 0x109 at all, which is the FSR dead end the
trace-section skill names first: an LFSR into the range does not exist either, so the pointer is
loaded from a variable. That the carry happens is measured twice, once as 0x109 advancing in the
same read where the seconds wrapped and once as the whole clock landing where the section below
predicts, so the gap is in the attribution and not in the reading.
0x27F78 is the calendar above it. It reads 0x10B + 1 and 0x10D + 1 and 0x10E, switches on the
second of those through an XORLW chain whose case values are 1 to 12, and groups them
{1,5} {2,6} {3,11} {4,7} {8} {9,12} {10}. Those are exactly the months whose first day falls on
the same weekday in a March to February year, so it is a day of week computation and the field
really is a month. The span is the detail worth keeping: grouping inside one calendar year gives
{1,10} {2,3,11} {4,7} {5} {6} {8} {9,12} and does not match, and the difference is what the
"January and February belong to the previous year" test at 0x28008 is for, which is the standard
way of putting the leap day at the end of the year. The comparisons against 90 and 100 on the year
field are the rest of the same algorithm, and the result is stored to 0x10C at 0x2806C. 0x280E0
is the day rollover, month modulo 12. Eleven of the twelve months are cases: June reaches February's
arm by falling through the last BNZ, which is the group the calendar puts it in.
What names the fields exactly, rather than up to an offset, is that the firmware subtracts them
from base slot 3's record. 0x27F20 seeks slot 3, advances the cursor two bytes past the 0xADDF
cookie, and calls two helpers. 0x27CC0 copies 0x108, 0x109, 0x10A into scratch, reads the next
three config bytes, and computes the difference in seconds. 0x27DFA copies 0x10B, 0x10D, 0x10E,
reads three more config bytes with one extra cursor advance between the first and the second, and
computes the difference in days. Line the two up against the record in
config-format.md:
| record | field | paired with |
|---|---|---|
+0x02 |
second, 0 to 59 | 0x108 |
+0x03 |
minute | 0x109 |
+0x04 |
hour, 24 hour | 0x10A |
+0x05 |
day of month, 0 to 30, section 322 | 0x10B |
+0x06 |
day of week, 0 = Sunday, section 322 | skipped, which is what the extra advance is |
+0x07 |
month, 0 = January | 0x10D |
+0x08 |
year, offset from 2000 | 0x10E |
So the clock's seven data memory bytes carry exactly base slot 3's encoding, field for field,
including its unusual choices: a zero based month, a zero based day and a weekday counted from Sunday,
section 322.
0x10C is the derived one, which is why the subtraction skips it on both sides.
| address | field | measured | how it is confirmed |
|---|---|---|---|
0x108 |
second | 47, 55, 3, 11, 23, 31 | the firmware's own modulo 60 loop, and the wrap was observed |
0x109 |
minute | 53, 53, 54, 54, 54, 54 | it carried in the same read where the second wrapped |
0x10A |
hour | 18 | the carry chain above the minute |
0x10B |
day of month | 6, so the 7th | paired with record +0x05, which is 0 to 30 |
0x10C |
day of week | 5, and 7 August 2026 is a Friday | the calendar's own output, counted from Sunday |
0x10D |
month, 0 = January | 7, so August | the month grouping above, and record +0x07 |
0x10E |
year since 2000 | 26 | compared against 90 and 100, and record +0x08 |
Corrected by section 322: the first pass was right. The date is 7 August 2026. The correction below overrode a reading of the firmware, the calendar's
INCF, with section 21's fit to the corpus, and that fit could not tell a zero based day from a one based one. Every date this section gives is a day early, and is left as written below this note.
The date is therefore 6 August 2026 and this section read it as the 7th first. The first pass took
the calendar's INCF ...,W as evidence that the day field is zero based, which fixed the weekday's
epoch by fitting rather than by reading, and Friday the 7th fits a Monday epoch exactly as well as
Thursday the 6th fits a Saturday one. The subtraction settles it because it pairs each RAM byte with a
record field whose encoding is confirmed on sixteen config samples, and the weekday then agrees with
the calendar independently: under the record's epoch 5 is Thursday, and 6 August 2026 is a Thursday.
A field split fixed by fitting one observation is not a reading, which is the same lesson as the
key code and the light band's flag bit.
And that answers a question section 21 left open. It says of the build timestamp that "what the
firmware does with it is not established". What it does, on arch 12, is compute how long ago the
config was built: 0x27F20 accumulates the seconds difference and the days difference into
0xF2D to 0xF2F, gated on two bits of 0x1A4.
The step is four seconds, not one, and the observed value set proves it. The seconds took 15
distinct values in 60 seconds, all of them congruent to 3 modulo 4, spanning 3 to 59. That is exactly
{3, 7, ..., 59}: the update adds four and 60 is a multiple of four, so a power cycle's residue
class survives every wrap. It also predicts the wrap that was measured, since 55 plus 4 is 59 and 59
plus 4 is 63, which the "subtract 60 while it is still 60 or more" loop turns into 3.
And that names one of section 47's log records. Case 3 of the log appender copies six bytes,
0x108, 0x109, 0x10A, 0x10B, 0x10D, 0x10E, in that order reversed. Reversed, they are
year, month, day, hour, minute, second: the record is a timestamp in descending significance, and it
skips 0x10C because the day of week is derived. Section 47 said what is logged "has not been
traced", and one of the five cases is traced now. The order is also an independent confirmation of
the field assignment above, since no other assignment makes that copy a sensible record.
6. What the clock reads is its own config's build date, and that is one battery pull from a
finding. It says 6 August 2026, 18:54, and the session that read it was 15:41 on 10 August. Two
things follow. A free running clock cannot show a past date after a power cycle, and this unit has
had its batteries out repeatedly, so something initialises it from stored data. And the stored date it
shows is one_spare_after_sync's own build timestamp, 2026-08-06 13:54:22, to the day and the
minute, with the whole difference being 5 hours 0 minutes and 25 seconds.
That is a strong hypothesis and it is not yet a finding, because the difference should be the uptime
and an uptime whose minutes come out at zero is a one in sixty coincidence. It is at least consistent
in the small: 25 seconds is congruent to 1 modulo 4, which is exactly what carries the seconds field
from the record's residue 2 into the residue 3 it was measured in, and a first tick that adds an odd
number of whole seconds is what the adder at 0x27A0E does.
One round of hardware settles it, and the prediction is seven values rather than a shape: take the
batteries out, put them back, and read 0x108 to 0x10E at once. If the clock comes from the config
it reads 22 54 13 06 05 07 26, which is the record's own fields in the order established above. If it
reads zeros, or a fixed epoch such as 1 January 2000, the initialiser is compiled in and the agreement
above is the coincidence. Either way it matters to an editor, because a config whose timestamp sets
the remote's clock is a config field with a user visible effect.
A refinement, written before the round and after the cable came out. Two things the prediction as committed does not say, and the second is the one that makes a negative result readable.
- The read needs the cable and the power cycle must not have it, because the port charges the remote
and buspower would keep it running. So the remote boots on batteries and is attached afterwards, and
a minute or so of uptime sits between the two. Only the seconds field moves in that time, so the
claim is the date and the hour and minute:
06 05 07 26exactly, hour 13, minute 54 or a little past. Seconds are22plus the elapsed, which predicts nothing. - A third outcome exists and it is about the procedure rather than the clock: a reading near the time of day the previous session saw, which today is around 19:00, means nothing reset and the round has to be repeated. Without naming it in advance, that outcome would read as the second one and would retire a live hypothesis on a failed experiment.
The clock comes from the config, measured¶
The round was run on 10 August 2026 at 14:28 UTC: cable out, batteries out for about twenty seconds, batteries in, cable in, read. The first outcome, to the minute.
| predicted | measured | |
|---|---|---|
0x10E, year |
26 | 26 |
0x10D, month |
7, August | 7 |
0x10B, day of month |
6 | 6 |
0x10C, day of week |
5 | 5 |
0x10A, hour |
13 | 13 |
0x109, minute |
54, or a little past | 55 |
0x108, second |
22 plus the uptime | 52 |
The config's record is 2026-08-06 13:54:22 and the remote read 2026-08-06 13:55:52, so the whole
difference is 90 seconds, which is the time between the batteries going in and the read. A
Harmony One initialises its clock from base slot 3's build timestamp at boot. Six of the seven
fields were predicted exactly and the seventh is the uptime, from a value that differs per config, so
this is not a shape that any initialiser would satisfy.
It also settles what the earlier reading was. That session found 18:54:47, which is the same record plus 5 hours 0 minutes 25 seconds of uptime. The minute agreeing exactly was a genuine one in sixty coincidence, and it pointed at the right answer: the reason to run the round was a coincidence worth one battery pull, and the round is what makes it a finding.
Two things came with it, both corroborating section 111's other half. The display light state read band 1, state 3, level 20 again, and this time it cannot be days old: it was computed inside the 90 seconds this remote had been running, on a fresh boot, from this config's group 1. And the battery gauge read 6 where the earlier session read 7, on a unit that had just spent twenty seconds with its batteries out and had not been charging. So the sampler does run in normal mode and stops in USB mode, which is exactly outcome 2 rather than a converter that never runs.
What is not established is the code that does it. The initialisation is confirmed by measurement,
sharply, and no routine that writes 0x108 to 0x10E from the record has been found: the direct
write search comes back with only the calendar's three, and the pointer is not set up by an LFSR. So
this is a behavioural finding with a firmware sized hole in it, and the hole is the one this project's
own method notes name first.
And this is arch 12 only, which is worth saying loudly because two of today's corrections were
exactly this mistake. Arch 14 and arch 9 carry the same eleven byte record and neither has been power
cycled and read, so nothing here licenses "a remote sets its clock from its config". Three sentences in
CLAUDE.md said it unscoped within an hour of this section being written, and they are corrected.
What that leaves open is bounded, and the boundary is the useful part. The write rail is to stamp the record with the moment of writing, and that is the right value on an architecture that ignores it for its clock as much as on one that does not, since it is the provenance field either way. So the open question would change a sentence in a document and no line of code. The arch 14 round is also the weaker one: a 600 on USB has not loaded its config at all, section 110, so a null result there would be ambiguous between "the clock is not config derived" and "USB mode never got that far".
What it means for an editor, which is less than the finding suggests¶
This section first wrote the consequence up as though the clock mattered to somebody. It does not, on our own account, two of these remotes having been here for years: the time is small on the screen, it runs badly wrong after a while, and it has never been used. That is the only evidence about the feature's value anyone here has, it comes from the person the feature was for, and it is worth more than an inference from the firmware.
So the consequence is narrow and it is still a rail. Write a config with a stale timestamp and the remote's clock is wrong by exactly that staleness, on every power cycle, until somebody sets it by hand. Stamping the record with the moment of writing costs nothing and a wrong clock on the screen is a visible defect, so FreeHarmony stamps it. The part worth keeping is the general shape rather than the clock: a round trip test that reproduces an input config byte for byte would reproduce the wrong clock on purpose, which is right for a round trip and wrong for a save. That is the first field in this project where emitting the input exactly and emitting the correct thing come apart, and there will be others.
Landing it produced a defect worth recording, and it was not the one predicted. The next step
after FIELD_RULES was proposed as "give the emitter the same distinction", on the reasoning that
emit.ts always rebuilds base slot 3 from the container it read. Checking the premise first, as this
project's own note about restructures asks, the emitter turns out to be right as it is: it exists
to prove the readers are complete by reproducing its input byte for byte, so carrying the timestamp is
exactly its job and stamping would break the measurement. What was actually wrong is that emit.ts
and edit.ts had each derived the day of week themselves, with a different spelling of the same
epoch and a different parser for the same string. Two copies of one derivation, both correct, and
nothing would have failed while they diverged, which is the defect this project bans for the opcode
table and had reintroduced within a day. There is one encoder now, clockRecordFields in gspm.ts
beside the decoder it inverts, and the test that guards it walks all eighteen containers asserting the
two are inverses on real records. The emitter's round trip only property is asserted from its own side
as well, because a later change that made it stamp would look like an improvement.
That distinction is code now, FIELD_RULES in packages/codec/src/edit.ts: every field whose
treatment on a write is not "carry it unchanged", with the section that establishes it and why it is
not the obvious other policy. applyEdits is the faithful path and saveEdits stamps, and neither is
the default, so a caller has to say which operation it means. The negatives are what the table is
really for, since they are the entries that cost something: base slot 1's version word looks computable
and is per config, section 81, and base slot 2's log area looks like something a writer should fill in
and is copied by every config in the corpus, section 47. Both are asserted byte identical after a save
rather than merely left alone in the code, a rule added without a test fails the suite, and the sharp
test is that a save of an unedited config changes exactly two runs: the seven timestamp bytes and
the two checksum bytes, on four containers spanning all four architectures.
Why it runs badly wrong, which the complaint about it pointed at¶
A 32.768 kHz crystal does not lose minutes a day. The tick that feeds the clock can, and it is eleven
instructions at 0x27BC8:
27bc8: MOVFF TMR1H,0xd47 ; take the high byte of a running timer
27bcc: MOVLW 0x3f
27bce: ANDWF TMR1H,F ; and clear bits 7 and 6 of it, in the timer itself
27bd2: RLNCF 0xd47,W ; the two bits that were there are the elapsed phase
27bd4: RLNCF WREG,F
27bd6: ANDLW 0x03
27be0: SUBFWB 0xf23,W ; against the phase the previous tick left
27bec: MOVFF 0xd49,gprF34 ; and the difference is the elapsed whole seconds
Bits 15 and 14 of Timer 1 are one second each, since the prescaled rate is 16384 Hz, so consuming them
by clearing them is arithmetically right: the bits below stay, and the fraction of a second is carried
rather than dropped. The loss is in how they are cleared. T1CON is 0x1F, measured on the remote
this session, and bit 7 of it is RD16, so the 16 bit read and write latch is off and every access
to this timer is an ordinary 8 bit one. ANDWF TMR1H,F is therefore a read, modify and write on the
high byte of a counter clocked from a crystal that does not stop for it. Whenever the low byte rolls
over inside that window, the carry it made into the high byte is written back over and 256 counts are
gone. Never gained: the write can only discard an increment, never invent one. 256 counts is 15.6 ms,
the tick runs about once every four seconds, and a loss on every tick would be 5.6 minutes a day.
There is a second mechanism in the same eleven instructions and it also only loses. The phase is two bits, so it can express at most three seconds of elapsed time. Anything that keeps this routine from running for four seconds or more, and a remote that spends time in an interrupt or asleep will, aliases whole four second blocks to nothing.
What is claimed and what is not. The two mechanisms are read and both are one directional, so the clock loses time by construction. The rate is not measured: how often the rollover falls inside the window depends on timing this project has not modelled, so 5.6 minutes a day is an upper bound and not a prediction. What corroborates it is our own account of years of use, which is that the clock runs badly wrong, and an upper bound of minutes a day is the right order for that. Measuring the rate needs the remote left alone for a day and read twice, which is cheap and has not been done.
7. Prediction 4 is wrong, and the way it is wrong is worse than the error. 0x3FFFF0 is not
erased. It reads 00 ff 00 ff 00 ff 00 ff 00 ff 00 ff 00 ff 00 00, and this repository already
knew that: docs/memory-map-one.md has carried the 0x3F0000 block as 00 FF repeating with the
last two bytes both 0x00, read off both remotes, since 9 August 2026. Section 47's own "what is not
established" still said the read "has not been done", and the prediction was written from that stale
paragraph. A prediction copied out of an open item that a later section closed is the same drift
step 4 of the finding skill exists to stop, with a hardware bill attached. The correction is
in place below.
The reads confirm the shape and extend it. Every 64 KiB block from 0x3C0000 to 0x400000 was read:
0x3C0000 and 0x3E0000 erased, 0x3D0000 to 0x3DEA91 the stored application firmware, 59391
bytes of it not 0xFF, and 0x3F0000 to 0x400000 the pattern, 32769 bytes of 0x00 at every even
offset and 0xFF at every odd one except the last, which is 0x00.
What the pattern does is the finding, and section 47's last open point closes on it. Base slot 2
declares the arch 12 log region as capacity 16, start 0x3FFFF0, limit 0x400000, in both One
configs. That is the top sixteen bytes of the pattern block, so the region a config reserves for the
log has been written before any config ever asked. Follow the boot scan with those bytes in hand:
0x2DB4Cwalkscapacitybytes fromstart, and for each byte that is not0xFFit records the cursor and the remaining count. The read helper0x2B8F8advances the cursor before0x2B88Areconstructs the address, so a non erased byte at offset k recordsstart + k + 1with countcapacity - k.- The last non erased byte is offset 15. So the recovered state is address
0x400000and count 1. - The append at
0x2DC0Atests that address against0x400000at0x2DC1A, and the failure branch zeroes the remaining count.
So the arch 12 log facility switches itself off the first time anything asks. The rail section 47 read as protection against a badly written config is what fires on a well written one, on both bench Harmony Ones, because of what is in the flash rather than what is in the config. No config in the corpus emits an append opcode either, so the facility is dead twice over, and a writer that someday wants to use it has to erase a 64 KiB block first, which is an erase inside the config region and therefore something the rails refuse.
What wrote the pattern is still unidentified. A block filled with the sixteen bit word 0xFF00, one
word of 0x0000 at the very top, on two units that have nothing else in common, reads like something
written before the remotes were assembled rather than by either firmware; it is not claimed here.
8. Prediction 5 confirmed. 0x01F580 and 0x01F5C0 both read 64 and 16 bytes of 0xFF over
USB. So the dual address hazard section 105 recorded is exactly as recorded and no worse: a firmware
TBLRD at 0x01F5C0 reads the on chip page 0xFF, where this family of units keeps 94 and
0xFFFF, and a READ_FLASH at the same number reads the external part, which is erased. The first
word is therefore distinguishable between the two memories and the second is not. It also gives
docs/memory-map-one.md's "everything else is erased" its first evidence for the
0x010000 to 0x020000 range, which had been asserted of a region no read had reached.
9. What this does to section 110, one day later. Section 110 measured five journal variables at
zero on a Harmony 600 and concluded that a remote on USB has not loaded its config. On arch 12 that
is false, and the sweep that carried the broad wording into CLAUDE.md and the trace-section
skill is narrowed to arch 14 here. The mechanism is the architecture difference this project has had
in its key facts table all along: arch 12 executes its config in place out of memory mapped NOR and
needs no load step, where arch 14 must copy from SPI serial flash. So the RAM polling method is alive
on arch 12 and dead on arch 14, which is the reverse of the architecture this project prefers to read
code on, and it is the third time "prefer arch 14, then port" has gone wrong about finding rather
than about reading.
Where it lands¶
packages/usb/test/hardware.test.ts, gated on the flag and on the One: the clock advancing with
TMR1 and T1CON beside it and UCON as the control, the display light bytes agreeing with each
other, and 0x3FFFF0 not erased with the container cookie as the negative. Its BENCH dump list is
corrected there too.
The test that ties the RAM to the config is in packages/corpus, not there, because it needs the
codec and packages/usb deliberately does not depend on it. It identifies the attached unit from its
own container, reads group 1 out of that container rather than out of a literal, and checks that the
cached level is the level that config states for the band the remote is in. Its negative is that no
arch 12 config's four levels include any of the firmware's defaults, which is what makes the positive
mean the config was read; that half runs without a remote.
tests/test_clock.py pins the seven fields against base slot 3's record, the modulo 60 loop, the
month grouping derived from the calendar rather than tabulated, and the log record's order.
tests/test_interpreter.py pins the boot scan arithmetic, that a region whose last byte is written
disables the appender, and the negative that an erased one does not.
Section 110 | the archive | section 112. Section 111 of the findings archive, which is frozen; the reference holds the current answer. The archive on GitHub.