Skip to content

196. The Harmony 300 and 350 firmware is published, and Logitech's own manifest states section 41's checksum

Section 193 fenced the file based family off from openHarmony on the ground that nothing here can reach them: no address, no firmware, no RAM. That was a statement about the USB protocol and it is still true of it. It read as a statement about the project, and that half is now false: the firmware of the Harmony 300 and the Harmony 350 is served by Logitech's own infrastructure, it is an ordinary PIC18 image, and every reader in src/harmony/ accepts it without a line of new code.

The route, which is a hidden screen in the client

Danny found an advanced screen in the Windows MyHarmony client, reached with Alt-F9 after signing in, offering a factory reset and a firmware update per model. It is not part of the client: strings on MyHarmony.exe yields https://setup.myharmony.com/remoterecoverytool/DefaultRRT.html, a live page that still answers 200 and 10883 bytes, the same length on two fetches. Each of its buttons calls recover.aspx?<mode>, and those pages are byte identical except for one parameter handed to a Silverlight utility:

SUSAddress=https://sus.dhg.myharmony.com, SUSChannel=production, Mode=<mode>,
TargetFW=, SpecialSUSStream=preview, discoveryServiceUrl=https://svcs.myharmony.com

Twenty four modes: factory and latest for ten products, plus recoverproducttolatest, unpair and xmppupdate. The ten are Touch, Ultimate, Ultimate One, Ultimate Home, Elite, 950, Pro, Home Control, Smart Control and Smart Keyboard, so the page covers the Linux generation only and no model of any architecture this project reads. The Harmony 300 and 350 are not on it.

The newer client has the same tool and not the same options. Harmony Desktop's web application, mirrored in the lab since section 132, carries an RRTMenu view reached by shift plus double click on the title bar, offering factory reset, update firmware, recover product and unpair. It has no XMPP entry. It does carry an in app XMPP toggle under hub settings, labelled a developer option, with a warning about creating an unsecured local access point, so the capability exists in both and only the older tool offers a firmware for it.

The update service answers, and the reason it looked closed was one header

sus.dhg.myharmony.com was probed on 27 August 2026 and returned 404 and 403 to every path tried, which was recorded as the firmware being unreachable. That was wrong and the cause is worth stating, because it is a general trap: the paths were right and the request was incomplete. The service requires a header, Logitech-SUS-Key, whose forty character value is hardcoded in Harmony Desktop's web application. With it the same paths answer 200. No login, no cookie, no account.

The path templates are not guesses either. They are in the discovery catalogue this project captured in section 132 and never read this part of:

.../SoftwareUpdates/product/{productId}/unit/{unitId}/image/latest?channel=<ch>&criticalOnly=false
.../SoftwareUpdates/product/{productId}/unit/{unitId}/features

{productId} is the skin and unit/0 is accepted, so no serial and no registered remote is needed. info and streams answer 404 for that unit; the other two answer for every product that has an image.

Two channels exist and no more, which was measured rather than assumed. production and preview return different builds; nine invented channel names, including xmpp and xmppupdate, all silently return the production build. So a wrong channel name is not an error here, which is exactly the shape that manufactures a false negative, and the control is that two names have to disagree before either means anything.

What it serves

Eleven images, listed with their digests in reference/checksums.md. Every file's length equals the length the service stated for it before the download.

One image serves a whole family, and that is measured rather than inferred from the sizes: skin 99 and skin 112 are byte identical, as are skin 97 and skin 106. Only the download filename differs per skin. The remote family sits at production 4.15.330 against preview 4.15.250, the hubs at 4.15.600 against 4.15.250.

Eight skins have no image on either channel: 78 and 104 by this route, 98, 101, 107, 109, 113 and 114. Separately, two factory images are published on the content network with no key at all, at Firmware/<skin>/firmware_factory.hfw2, for skin 99 and skin 106; every other skin answers 403 there.

The Harmony 300 and 350 image, and what makes it a finding rather than a download

product/104 serves 46773 bytes, which is two orders of magnitude smaller than the Linux images and was the reason to look. It is a ZIP holding a Description.xml and a Region_2.EZUpgrade, which is exactly the shape of the three .hfw packages this project has had from the start, and its <INTENDED> names skins 78, 79 and 104. Skins 78 and 79 are both a Harmony 300 and they are a regional pair, which is measured rather than assumed: the product table gives 78 region 1 and 79 region 2, the same shape as the Harmony 600's 71 and 73 that section 131 identified. 104 is the Harmony 350, region 3, with no pair. So one image covers both models and both regions of one of them.

tools/ezextract.py decodes the region wrapper to 73472 bytes with no change to the tool. Then, in order, five things that could each have failed:

  • firmware.verify_checksum passes and firmware.parse_header finds the HG magic at offset 8.
  • the header's version is BCD 0x14, and the package's own manifest says VERSION="1.4".
  • the header's byte 6 is 1, the value the Harmony 600, 650 and 700 images carry and not the Harmony One's 0. This was read as a family byte and it is not one, section 295: it is the top byte of the image's 24 bit length, 1 on every image here longer than 64 KiB, and the Harmony 350's is.
  • loadaddr.find_base answers 0x9000, where 1581 of 1582 targets land on a function boundary, 99.9%, against 32.5% for the runner up at 0xC000, which reaches only 1460 of them. Quoting the two raw hit counts side by side would have compared different denominators. That is the decisive margin this project asks for, and 0x9000 is the arch 14 execution base.
  • the instruction at 0x9000 is GOTO 0x1AED4 and the header's own entry point field is 0x1AED4. Two fields, one answer, which is what makes the derived base more than a score.

What none of that says is which architecture a Harmony 350 is. Byte 6 was never going to say it, being part of the length; section 194 read a Harmony 350's format word and section 195 its skin, and neither is an architecture either. The manifest's PATH="/fw/normalmode" is a named file, which is section 193's reading exactly, so the storage being addressed by filename and the processor being a PIC18 are both true and were never in tension.

Logitech states section 41's checksum, from a route with nothing in common

The closure worth having. The package's Description.xml carries

<CHECKSUM SEED="0x4321" OFFSET="0x0004" LENGTH="0x11EF8" EXPECTEDVALUE="0x8F7B" TYPE="XOR"/>

and recomputing a XOR of little endian 16 bit words over exactly that range reproduces 0x8F7B. The seed, the word width and the algorithm are section 41's, derived here from config container trailers with no firmware involved and no manifest in sight. So the vendor states a rule this project inferred, in a file type that shares no bytes with the one it was inferred from. Solving for the seed rather than asserting it gives 0x4321, which is what makes it a measurement.

The value is also stored in the image's own first two bytes, little endian, immediately below the range it covers.

gspm.xor_words is that arithmetic, and it was extracted from trailer_checksum in this commit rather than copied into the test. It now has two consumers over two different ranges, which is the only arrangement this project's oldest rule allows: a private copy in the test would have been a second derivation of the one thing, and the pair would have been free to drift.

The XMPP mode, and what stays inference

xmppupdate is the only mode with no product name attached, and the hub's preview stream is pinned at 4.15.250 against production's 4.15.600. The episode where a hub firmware removed the local XMPP control interface and a later one restored it as a developer option is a matter of public record, and those version numbers fit it. It is not established here. The service's feature list names 33 features for the hub on both channels and none of them mentions XMPP, and SpecialSUSStream=preview appears in every recovery mode's parameters rather than only in that one, so the parameter does not single it out. Both hub images are in the lab, so the way to settle it is to compare them, and that needs squashfs tools which are not installed.

The mode is aimed at the hub family in any case, so it is not a route to anything for a remote on this bench: a Harmony Touch has no network interface for a local control API to listen on.

What it costs and what it opens

Nothing about any rail. This is a download from a vendor's public endpoint and no remote was touched.

What it opens is arch 9's position as the only architecture here whose firmware came from hardware. A Harmony 350 sits on the bench, unopenable by openHarmony by construction, and its firmware is now readable at the same load address as the architecture this project prefers for reading code. Whether its config is reachable at all is untouched by this and stays section 193's question.

tests/test_harmony_350_firmware.py, ten tests, starting from the ZIP as downloaded rather than from any file this project produced out of it, with a flipped byte as the checksum's negative control.


Section 195 | the archive | section 197. Section 196 of the findings archive, which is frozen; the reference holds the current answer. The archive on GitHub.