Skip to content

202. MyHarmony does not compile a configuration for a Harmony Touch at all

Why every attempt to fetch a Harmony Touch's configuration from Logitech's service ends in status='Error' six seconds in, read out of MyHarmony's own source on 28 August 2026. It is not the call, it is not the account and it is not section 145's policy field. The client never makes that call for this product.

The branch, in the client's own words

SyncRemote in RemoteSyncUserControlModel chooses a route from the product's capability list, and only one of the four routes compiles anything:

the product declares route what it does
mode 3, or SupportsProvisioning UpdateProvisionSupportedRemote sets config not required and provisions
SupportsCertificateActivation UpdateProvisionSupportedRemote the same
LocaleEnabled UpdateRemote(<language>) compile, download, write the file
none of those UpdateRemote("Not Implemented") the same, with a placeholder language

The service states each product's list, and the three remotes on the calibration account divide exactly along it. A Harmony One and a Harmony 600 declare LocaleEnabled and not SupportsCertificateActivation. A Harmony Touch declares SupportsCertificateActivation and not LocaleEnabled. So the two older remotes take the compile route, which is why nine compiled configurations exist here, and the Touch takes the provisioning route, which reaches StartDSProvisioningOperation and from there sends the remote itself a request for its provisioning information over the other protocol. StartCompileWithLocaleAndSettings is never reached on that path.

So a Harmony Touch's configuration is not produced as a downloadable file by this service, and the error is the compiler being asked for something this product has no route to. What the account holds for it is devices and activities; what gets onto the remote is arranged between the client and the remote, not handed over as a compiled artefact.

Two corrections, and the second is the instructive one

StartCompileWithLocale is the simulator, not the sync. Its only call site is CompileEZSim, which builds the on screen simulation of a remote, and the sync path uses StartCompileWithLocaleAndSettings, which is exactly what this project's own script has been sending all along. The reading that MyHarmony's sync uses a different operation is dead, and it lasted about an hour.

It came from searching a compiled assembly for a name. The method exists in the assembly, the sync module does reference it, and the two facts together looked like a call site. What separates a name from a call is the surrounding code, which a string search cannot see, so a name found by adjacency is a hypothesis at best. The decompiled source was in the lab the whole time, 1999 files across seven assemblies, and it was not reached for because the register described that directory as this project's own service client rather than as the vendor's decompiled one. A catalogue's description is load bearing: the row was accurate about the parent directory and wrong about the square, and the cost was a wrong reading published in four documents.

What is ruled out, so nobody re-derives it

  • The product policy field. Skin 99 is IsEnabled true in the global product table, unlike the Harmony 525 of section 145. The per account product record reports IsEnabled false for the Touch, the Harmony One and the Harmony 600 alike, so that field is not the compile gate in either direction and the two records must not be conflated.
  • The settings payload. Fetched the way the client fetches it, through GetRemoteSettings on the json2 base, and its fields are identical to what the existing script already sends.
  • An empty account. The Touch's record holds two appliances and one activity.
  • The sync required flag. It reads false for the Touch and also for the Harmony 600, which has compiled successfully here.

Section 201 | the archive | section 203. Section 202 of the findings archive, which is frozen; the reference holds the current answer. The archive on GitHub.