226. Which unit is on the cable, read off the unit instead of asserted¶
WritePermission had a boolean called targetIsTheSpareRemote and every caller passed true. It was
the last of the three world facts section 188 recorded as things the library cannot check, and the
reason given was sound as far as it went: two Harmony Ones enumerate identically, and listHarmony
deliberately drops the serial so that one cannot reach @harmony/probe's publishable report.
It can be checked, and the route was already read. The mistake was in what the check would have to be.
The proposal that was wrong, and why it was wrong¶
This project's own first answer, on 30 August 2026, was to identify the unit by its configuration: the rehearsal already compares the block it is about to write against the lab dump byte for byte, and a configuration is unit specific, so make that the identification. Danny refused it on cost and then asked the question that settles it, whether Logitech does anything of the kind.
They do, and they do it with the serial. RemoteManager/AddRemoteToAccount takes three brace wrapped
GUIDs and ValidateRemote refuses a synthetic one, section 136, which is how a remote is bound to an
account. So the configuration fingerprint was reinventing a serial check the hard way, and the
instruction was to do what the vendor does.
The general lesson is the one worth keeping, and it is decision 2 in CLAUDE.md again: before
working out how something should be done, look at how their software does it. The fingerprint idea had
an argument behind it, a measurement behind it and a script already performing half of it, and it was
still the wrong shape, because a question of the form "how do you tell two of these apart" is one the
people who built them answered first.
The route needs no new protocol¶
docs/usb-protocol.md found a 64 byte identity block at internal page 0xFF offset 0xF400,
confirmed on three remotes across two architectures, as four 16 byte fields. The closure recorded there
is strong: concordance -i prints three GUIDs for a connected remote, the lab holds that output for one
exact unit from months earlier, and all three appear in the block in the same order, the latter two
mixed endian. So an address predicted in advance returned three values obtained without this code.
readUnitIdentity is one READ_FLASH of that window. Nothing is written and the count is even, which
matters: an internal read of an odd count never terminates and hangs the remote, section 94.
The trap, which is most of what the module is for¶
The field named the serial cannot identify anything. It is 0xEE filled on all three remotes read
here, concordance -i agrees the serial is unset on the spare, and docs/usb-protocol.md already
recorded it as a field nobody writes. So the obvious implementation, comparing the field actually called
the serial, matches every unit against every other and reports a confident yes. That is the exact
failure the whole path exists to prevent, arrived at by doing the natural thing.
The per unit values are the two GUIDs after it, 32 bytes, and that is what unitDiscriminator returns.
identifiesAUnit is the refusal that goes with it: a block whose GUID fields are uniform filler, in
any of the three fills this project has seen in that region, is not an identification, and sameUnit
throws rather than answering false. False would read as "a different unit" where the truth is "this
cannot be told", and a rail acting on the first refuses for a reason that is not true.
The control: making unitDiscriminator return the serial field instead of the GUIDs fails nine tests
across two files, and the reversal was compared byte for byte against a copy taken first.
The rails take two blocks, not a boolean¶
Same shape as section 225 one section earlier, and by now it is a pattern rather than a fix: the
permission carries the identity read off the remote and the identity of the unit that may be written
to, and the rail compares them. assertUnitIsPermitted is that rail, and it now guards flash writes,
erases, RAM writes and the session end escape, all four of which previously read the boolean.
No table of units lives in this library. A unit identity is that remote's hardware identity, and Danny's decision on 30 August 2026 was that the values stay out of this public repository. Where the expected one is kept is the caller's business:
- on the bench, a file in the private lab,
units/<label>.txt, reached byunitIdentityinpackages/lab, which is deliberately not inIMAGES: that registry is the corpus andPARSEABLEis discovered from it, so registering a 64 byte identity would move about seven corpus wide totals for a file that is not a configuration - in FreeHarmony, stored with the user's own data alongside everything else it knows about their remote, which is Danny's statement of the product design the same day
Both want the same thing from here, so the stored form is plain hex of the 32 bytes, 64 characters, which round trips exactly and has nothing for a later reader to get wrong. A GUID rendering would have, since the two after the serial are stored mixed endian and every reader would have to agree which way round to print them.
packages/probe is untouched, deliberately. Its report is meant to be published by other people,
so the reason its enumeration path carries no serial is stronger than this rail, not weaker: publishing
one's own hardware identity is a decision an owner can take, and publishing a stranger's on their
behalf is not.
What this replaces, in two scripts¶
rehearse-block.ts claimed that its dump allow list and its byte compare together said which unit was
on the cable. They do not, and the review of 27 August recorded that they prove content: another
Harmony One whose selected block happened to match would have passed as the spare. That correction sat
in docs/findings.md for three days while the script restated the dead claim in its own docstring, so
it is a fifth instance of a fact landing in one place and not in the other four.
end-session-experiment.ts identified the unit by comparing the first 32 bytes of the config region
against the spare's dump, which is the fingerprint idea in miniature, written before anybody had asked
whether the vendor had a better one.
Both read the identity block now and both refuse when the lab holds no recorded identity, which is the correct default: with no record there is nothing to compare against, and that is exactly when a write must not proceed.
Measured on the spare, the same day¶
The paragraph here said the rail was implemented and unexercised. It is exercised now, on the spare Harmony One, all reads:
- the block identifies the unit.
identifiesAUnitdid not refuse, which is the first confirmation on hardware that the two GUID fields are written on this unit and that the route works at all. Its first eight characters are66c3ad17, which is as much as belongs in a document - the whole chain runs: the rehearsal's dry run reads the identity, matches it against the lab record, reports the compatibility gate as zero of six fields stated, compares the block against the dump byte for byte and prints its plan. Nothing was written
- it refuses another unit. One hex digit of the recorded identity changed, and the run refuses before reading anything else. The change was reversed and the file compared against a copy taken first
- it refuses no record. With the file moved away the run refuses and says where to put it, which is the state a fresh bench is in
read-identity.ts --record <label> is what wrote the file, and three things about it are deliberate:
it writes the value rather than printing it, since that value identifies a specific piece of somebody's
hardware; it refuses a block that cannot identify a unit; and it refuses to overwrite a different value
without --force, because a label pointing at the wrong remote is worse than one pointing at nothing.
What the first record rests on is Danny's word, unavoidably: the operator says which unit this is once, and every write afterwards is checked against it. That is the same arrangement as Logitech's, where a serial is read off the hardware and bound to an account record by whoever is holding the remote.
Of section 188's three world facts, one is now measured, section 225's is performed by the rail, and
originalDumpVerified is the honest ceiling: the library cannot know where a caller's bytes came from,
so the rehearsal passes the measurement it already made instead of a literal.
Section 225 | the archive | section 227. Section 226 of the findings archive, which is frozen; the reference holds the current answer. The archive on GitHub.