235. 0x7C is a delay in tenths of a second, so every architecture states a power on delay¶
Section 234 found a device's power on delay on arch 14 (Harmony 600 and 700) and reported that the
other twelve containers with devices in them state none. That was true of the variables and it
was the wrong conclusion about the format: arch 8, 9 and 12 state the same number as an instruction,
in the action list that switches the device on. It is opcode 0x7C, whose unit section 70 measured
everything about except what it counts.
This matters beyond tidiness. The only remote this project may write to is a Harmony One, arch 12, and until now nothing readable on one was worth changing. A power on delay is one byte.
Where it is¶
A device's Power variable in base slot 13 has a transition from 0 to 1 carrying one action list
instruction, section 86. That list sends the power code through a nested list and then, at its own
top level, carries exactly one 0x7C naming the same infrared group:
list 3196 named by Denon_Power 0->1
7F 0x1C9 run the list that sends the power code
7C 0x003C group 0, 60
The split has no exception either way. Over twenty containers, every one of the 57 power on
transitions on arch 8, 9 and 12 carries exactly one 0x7C at that top level, and every one of the
16 on arch 14 carries none. The group it names is the device's own group on 56 of 56, the odd one
out being a device no route names at all.
Top level only is the rule and it is load bearing. The nested list that sends the code carries a
0x7C of its own with the value 1, one per send, which is the ordinary per send quantity section 70
described. A reader that walked into it would sum the two and report 61 where the delay is 60. Made
into a control: reading one level deeper makes three of these tests fail.
The unit, settled by a pair Logitech compiled for us¶
Section 70 could say 0x7C is per device, bounded at 450, consumed by the infrared sender and
folded by taking the larger of two consecutive requests, and could not say what it counts. The
closure is a calibration case rather than more firmware.
Logitech's service compiled a configuration for the same three devices twice, once for a Harmony One and once for a Harmony 600, sections 121 and 125. The two architectures keep the delay in places with nothing in common. Joined on the device's own name:
| device | Harmony 600, a state variable | Harmony One, a 0x7C operand |
|---|---|---|
| the television | 35 | 35 |
| the Blu-ray player | 15 | 15 |
| the receiver | 15 | 15 |
The Harmony 600 side's unit is stated by that config's own screen, 451 labels from ( 0 sec ) to
( 45 sec ) in tenths, section 234. So the operand is tenths of a second and 450 is 45 seconds.
Scored against the wrong answer. The other candidate for a quantity sitting beside a power code is the inter device delay, and the Harmony 600 states that too: 5 for all three devices. The Harmony One's numbers are 35, 15 and 15, so nothing matches it. A third configuration of the same three devices, compiled for the same Harmony One on a different day, gives the same three numbers again.
What the values look like¶
Across twenty containers and four architectures, 57 inline delays and 19 in variables, 76 of the 83
devices in the lab. The seven without one have no Power variable at all, which is what an audio
switch or a media centre looks like: nothing switches them on. This said 56, 75 and eight until
3 September 2026, and no delay moved: a delay is found through the device's name, and the inventory
left a set top box on the spare Harmony One unnamed until section 240 gave it the device list as a
naming route.
The distinct values are 10, 15, 20, 25, 30, 35, 50, 52, 60, 80, 85, 95 and 100 tenths. A television is usually the slowest thing in the room, at 8 to 10 seconds; an amplifier reads 5.2 and a games console 2.5.
Seven of the 56 sit exactly at 100, which is the firmware's own fold cap, section 70. That is the largest delay a single instruction can express, so it is also the rail below.
A second route to the identifier join, agreeing with the screen¶
Section 234 joined a device's infrared group to Logitech's numeric identifier through the screen,
because base slot 0 relates the two vocabularies nowhere. The same power on list gives a second
route on arch 14, and it needs no drawn text: where the other architectures put a 0x7C, arch 14
puts a 0x72 naming that device's own PowerOnDelay_<identifier>, and the list's 0x7D names the
group. The two are related structurally.
18 of 18 agree with the screen route, over every 0 to 1 transition in the four containers that
carry delay variables. It does not replace the screen, which answers for all 19 devices where this
answers for 16: a device nothing switches on has no such list. So it is corroboration, and
deviceIdOfGroup keeps the screen.
The same 0x72 gives the range a third statement. Its high byte selects a base slot 14 record, and
the record for a delay variable has 451 entries, one per position of the slider, matching the 451
drawn labels and the 0 to 450 range exactly.
For a writer, and this is the point of the section¶
Changing a device's power on delay on a Harmony One, a Harmony 525 or a Harmony 880 is one byte:
the low byte of a 0x7C operand in a base slot 10 action list. Nothing moves, no length changes, no
count is restamped. powerOnInstructions returns the list, the position in it and the current value
for exactly that reason.
Three rails come with it.
- 100 is the ceiling of a single instruction, not 255. The firmware folds two consecutive quantities for one device by taking the larger, except at 100, where it pushes a second entry instead, section 70. So a delay above 10 seconds is a run of instructions and raising one past 100 is a length change rather than a byte edit. Seven devices in the lab already sit at the cap.
- The value is per device and consecutive ones interact. Section 70's fold rule means an editor that inserted a quantity next to an existing one would change the existing one's effect.
- Arch 14 is not writable this way. Its delay is a state variable, so changing it is an edit to a base slot 13 record, and it had no write target anyway until section 281 gave it the Harmony 650.
deviceDelays reports both, with a source of variable or instruction, and refuses to invent
the fields the inlining architectures do not have: no identifier, no default, and no inter device
delay. Where those architectures keep an inter device delay, if they keep one, is open.
Logitech's own account says the same thing, in milliseconds¶
The calibration above is two configurations against each other, which is strong and is still inside
the format. The check from outside it turned out to need no write at all, only an operation nobody
here had called: UserFeatureManager/GetUserFeatures. A device's delay is not on the device record,
which is why setdelay.py in the lab cannot reach it; it is on a PowerFeature hanging off the
device, and that manager lives on its own UserFeaturePlatform rather than on HarmonyPlatform
where every other one does. Guessing the latter answers 404 with an empty body, which reads
exactly like the operation being gone. The path is in the service's own discovery reply, captured in
the lab since section 132.
Asked for the account that holds the spare Harmony One, it states a PowerOnDelay per device in
milliseconds. Against one_spare_myharmony, the configuration their service compiled for that
record, joined on the device's own name:
| what the config carries | what the account says | |
|---|---|---|
| 60 | 6000 | the receiver |
| 50 | 5000 | the television |
| 15 | 1500 | the set top box |
| 15 | 1500 | the games console |
Four of four, at exactly a hundred times. The config's fifth device is a media player with no
Power variable, and the account holds five more devices no compile has used.
Scored against a wrong answer that is really in the data. PowerFeature states both the current
delay and the default Logitech's catalogue gave the device, and on two of these the owner has tuned
it away: the television reads 5000 against a default of 10000 and the receiver 6000 against 2000.
The configuration carries the current value both times, so the field is PowerOnDelay and not
DefaultPowerOnDelay, and a reader that took the other would be wrong on half of this sample.
That also refines section 234's remark that a config's delays "are the ones Logitech's database gave the device rather than something its owner tuned". That was true of the four arch 14 containers, where current equals default for all 19 devices, and it is not a general rule: this account has two devices where they differ.
The inter device delay is not one of these instructions, measured¶
The same reply states an InterDeviceDelay per device too, 500 milliseconds on most and 1000 on the
television, so there is a discriminating value to look for. There is no 0x7C carrying 10 for the
television's group anywhere in that configuration, and none carrying 5 for the three devices set to
500. So where arch 8, 9 and 12 keep the inter device delay is open, and now on a negative
measurement rather than on nobody having looked.
powerOnInstructions and deviceDelays in packages/codec/src/inventory.ts;
packages/codec/test/inventory.test.ts, where two of section 234's tests were rewritten rather than
removed because this section refuted their titles. The service reply is a dated capture in the
lab, since an account is a live thing whose contents change and a test that read whatever is there
today would be asserting about the future.
Section 234 | the archive | section 236. Section 235 of the findings archive, which is frozen; the reference holds the current answer. The archive on GitHub.