Skip to content

244. The remote was not calling itself unprogrammed, and there are thirty screens it could have shown instead

Date: 3 September 2026. Status: the table is measured in five containers across two architectures, with packages/codec/test/status.test.ts behind it. Which screen the spare Harmony One showed is Danny's observation, twice, and the calibration below is what makes it more than a recollection.

The question was why the spare Harmony One calls itself unprogrammed after a write. It does not. The message it shows is "Go to Website to update settings", and it is one entry in a table of status screens the firmware ships, alongside separate entries for an invalid configuration and a corrupted one. A remote showing the website screen is not complaining about its configuration at all, so the open question was written down in terms that presuppose the wrong answer.

The table

The container this project calls the safe mode container, at flash 0x002000 on a Harmony One, holds 30 status screens. Their text, in the order the container stores them:

0 Go to Website to update settings
1 USB Initialization
2 Bootloader Locked
3 Real Time Clock
4 IR LEDs and Photodiode
5 to 8 FLASH Memory ID, Erase, Write, Clear
9 LCD Module Failed
10 PLL Failure
11 BootRAM Truncated
12, 13 Safe Mode, Safe Mode Requested
14 to 17 Battery Low, Battery Fast Charge, Battery Trickle Charge, Battery Charge Complete
18 IR Sending
19 Invalid Configuration
20, 21 Bootloader Bad Image, Bootloader Upgrade Failed
22 to 24 Battery ADC, LightSense ADC and Revision ADC Not Calibrated
25 Application Terminated
26 Configuration Corrupted
27 Missing License
28 USB CONNECTED
29 Needs to be setup. Battery Charging

Arch 14 holds the same 30 in the same order with five more in front: Update Successful, Upgrade Successful, Update in progress, Learning, and Firmware upgrade in progress. So a Harmony 600 or 700 ships 35 and a Harmony One 30, and the difference is a prefix rather than a different table.

The closure is that five images agree by two routes. Two arch 12 containers, one read off a remote's own flash and one extracted from Logitech's firmware package, are identical; three arch 14 containers, a Harmony 600's, a Harmony 650's and the Harmony 700 package's, are identical to each other; and the Harmony One's 30 are the arch 14 35 with the first five removed, exactly. Nothing in the reader knows what any of these words are, so a decoder slip would have to make the same slip five times in two typefaces.

Why this answers the bench question, and the calibration that makes it evidence

Two screens were seen on the spare that afternoon and both are in this table. On the cable it showed USB CONNECTED, which is entry 28 and is spelled in capitals; unplugged it showed entry 0. The capitals matter, because the application image carries its own USB Connected string in German, Spanish, French and English in title case, so the two spellings say which of the two was on the screen.

The icon settles it, and that is a measurement rather than a spelling. Not one of the 30 screens draws a bitmap or a picture: they are text on a bare screen, in all five containers. So an icon on the screen means the application is drawing its own screen and not one of these. Danny described the screen after the write as USB CONNECTED with no image, and the screen a connected remote shows in its ordinary state, checked on the cable on 3 September 2026 with the application confirmed to be running, as USB Connected with the icon. Each description fits exactly one of the two, so the remote was not in its normal interface after the write.

The calibration is that the same remote showed a different screen when its configuration really was broken. After the attempt that was killed mid write, with 24 blocks of one configuration and one block erased, it said its configuration was corrupted, which is entry 26. After a write that completed and read back byte for byte, it said go to the website. So the table's distinction is one the firmware actually draws, and the remote reports the two states differently. That is a known answer case rather than a reading of ours: the corrupted screen was seen at a moment when the flash was independently measured to be inconsistent.

And position is not what selects a screen, which was read off the website message being entry 0 on the Harmony One and entry 5 on arch 14. Section 249 refutes it and position is exactly what selects one: the firmware raises a status code, the same number on every architecture, and the record it reaches is that code plus a base per container, 0 on arch 12, 5 on arch 14 and 11 on arch 9. What this paragraph had right is the narrower point it was reaching for: entry 0 is not a default shown when nothing set a code. It is code 0, and code 0 has a meaning.

What is still open, and what would settle it

Which condition selects entry 0 is unread; section 249 reads it, and the reason given here for the failure is worth keeping because it was the wrong reason. The application image holds no variable written with a spread of literals in the range of these indices, and that is true and useless: the index that matters is zero, written by a CLRF, so a search for literals was looking for the one thing that is not there. The routine that draws one is 0x2871C and it has five callers. Two candidates remain and one command distinguishes them: if the remote is running its application it is the application drawing a status screen, and if it is not, the screen belongs to safe mode or the bootloader, which is where this container physically sits. read-identity.ts prints the software type, 0 running normally and 4 in safe mode, so reading it on the cable straight after a write is the measurement, and it is a single read.

A read only session does not trigger it, measured on 3 September 2026 on the spare Harmony One. One GET_VERSION and 2048 single byte reads of its data memory, then the cable out: the remote went straight back to its ordinary activities screen. So a host merely talking to it is not the cause, and the trigger is something the write does that a read does not. The rung above this one, a full configuration read, which is what the writer performs before it writes anything, is unrun.

Two things follow for the meantime. The open question is reworded rather than answered: a remote that has just been written to shows a status screen asking for a sync, and what sets it is unknown. And that wording is dead, since the remote says nothing of the kind and the table has two other things it says when a configuration is wrong.

Where it lands

  • packages/codec/test/status.test.ts: the counts, the five way agreement, the prefix relation, and the negative that the message is neither of the configuration screens.
  • docs/config-format.md: what the container at flash 0x002000 holds.
  • Section 242's open question, reworded in place, and reference/superseded.md.

Section 243 | the archive | section 245. Section 244 of the findings archive, which is frozen; the reference holds the current answer. The archive on GitHub.