261. What connects a key to a stored code on arch 16, and why the names cannot be checked there¶
4 September 2026. Section 260 found a configuration naming its own devices and commands and said the join to the records was open. This is the attempt, and it half closes: the mechanism that connects a pressed key to a stored code is exact on arch 16, and the naming cannot be corroborated on that container at all, for a reason that is worth more than the join would have been.
The mechanism was already read, and it holds here¶
An action list instruction is a u16 operand and an opcode. Opcode 0x7D sends an infrared code, and
section 33 read its reference as one to one; docs/config-format.md states that the operand's high
byte is the group and packages/codec/src/inventory.ts has split it that way since section 126. So
this is an extension rather than a reading, and the grep that found the prior art ran before the claim
was written rather than after, which is the rule sections 209, 213 and 256 kept restating.
On the Harmony 350 it closes exactly. Its 171 action lists hold 130 send instructions with 130 distinct operands, against 130 infrared records, and splitting each operand gives:
| high byte | sends | low bytes | records in the group of that index |
|---|---|---|---|
| 0 | 52 | 0 to 51, contiguous | 52 |
| 1 | 48 | 0 to 47, contiguous | 48 |
| 3 | 30 | 0 to 29, contiguous | 30 |
So every record of every non-empty group is referenced exactly once and nothing else is referenced. That is the closure: a count of sends matching a count of records would be a coincidence, and a contiguous cover of three groups of different sizes is not.
The other opcodes in those lists are the ordinary ones: 0x7C 136 times, which is the pause section
236 read, 0x07 146 times, 0x7F 30 times, which is section 26's call to another list, and 0x1F 31
times.
The named devices are not in the group order, and the candidate is the obvious one¶
The archive names devices 0, 1 and 2. The groups holding records are 0, 1 and 3, with group 2 empty. So the k-th named device is the k-th non-empty group, which fits and is one container's worth of evidence. It is not in any code and is recorded as a candidate: what it would take to settle is a second container, or a device deleted and the two compared, which is a ten minute job on the bench and is why section 259's note about a programmed dump matters.
Why the command names cannot be checked, and this is the finding¶
The plan was section 229's route in reverse: identify each group's codeset out of Logitech's catalogue
by the numbers its records decode to, take the command names from that codeset, and compare them with
the archive's. It cannot run. No record of the Harmony 350 decodes to a number at all, 0 of 130,
by any of the three readers here: framesOfPulses, framesOfSegments and biphaseFrames.
The reason is what the three groups are. Every one of them is biphase, where a bit is which half of one cell carries the carrier, and each defeats a different reader:
- group 1 is
Microsoft 30 Bitand is identified with no catalogue at all: its lead in matches that row of the rhythm table on all thirteen pulses, mark for mark and microsecond for microsecond. Our biphase reader still declines it, because that family's double width trailer bit ends the cell run, whichbiphaseFramesdocuments as deliberate; - group 0 opens
+2662 -870 +468 -866and matches no row in the table's 681 entries. Its body mixes 468, 866, 433, 1335 and 1307 with a 457 and 440 pair further in, so it is biphase at more than one half cell width, which is RC6's shape; - group 3 opens
+900 -900 +1800 -1800with a 3515 gap, which is a 900 microsecond half cell, and matches no row either.
Three consequences, and the third is the one to carry.
The archive is the only naming route on that remote. Everywhere else the catalogue can name a command because the record decodes to a number; here it cannot, so a Harmony 350's commands are nameless without the archive and fully named with it. That inverts the usual relationship between the two sources.
On that remote, and not on this architecture, which section 265 had to narrow: three of the four device groups of a programmed Harmony 300 decode and are named straight out of the catalogue. So what shuts the route is the family a device speaks, and this unit is one whose three devices all happen to speak families this decoder refuses.
And the refusal was ours, section 266. All 130 of this container's records read as biphase frames
once biphaseFrames stopped requiring its caller to trim the leading gap. So nothing about these codes
is unreadable and the claim above holds only of the pulse distance readers, which is what the two
this section measured are. The naming route is not shut, it is unbuilt: make catalogue matches numbers
from the pulse distance reader alone, so it cannot identify a biphase device group, and that is a gap in
the tool rather than in the data.
Two biphase families are unidentified, and they are the first in this project found in a configuration rather than in Logitech's catalogue. Naming them is the ordinary route, which is Logitech's own definitions, and the archive checkout holds 684 of those.
And the archive's names stay unverified, in the document's usual sense. They are Logitech's word and the owner's, with nothing here to check them against, which is exactly the standing of an entry taken from the device catalogue under decision 15.
What it changes¶
Nothing in packages/codec changes: IR_SEND_OPCODE and the operand >>> 8 split in
inventory.ts already state the reading. What is new is the assertion that the split covers a
container's records exactly, which nothing checked before, and the test walks every configuration
that states an action list table rather than a list of names, so a sixth architecture joins it by
having its slot mapped rather than by anyone editing a test.
Section 260 | the archive | section 262. Section 261 of the findings archive, which is frozen; the reference holds the current answer. The archive on GitHub.