Skip to content

292. The Harmony 650's screen light timeout is a timer in the configuration, and MyHarmony calls it GlowTime

Asked for from the bench: the 650's screen goes dark after six or seven seconds, which is too soon to be comfortable. No setting for it exists on the remote.

The candidate

Logitech's configuration service answers GetRemoteSettings with a remote's settings, and seven distinct answers are saved in the lab: five in work/myharmony/responses/, in six files since the Harmony Touch's is saved twice, and two in responses-account2/. A Harmony 600's and a Harmony 700's each list three settings, GlowTime, TiltSensor and RemoteAssistant, with GlowTime at 20 and a default of 20 on both. A Harmony Touch's names a ScreenTimeout instead, and the Harmony 525's and the three Harmony One+ answers list no settings at all. Which remote an answer describes comes from its RemoteName and not from its file name: responses-account2/GET_RemoteSettings_skin22.json answers for a Harmony 700 while the file of the same name in responses/ answers for a Harmony 525, skin 22 being the 525 in packages/usb/src/models.ts. GlowTime at 20 also appears in GET_UAD_Settings, saved in four directories across both accounts and always for a Harmony 600, and GetProductCapabilities states its default as 20.

Client sourced. The 600's GetRemoteSettings answer was saved in the session that compiled calibration_h600: its file is dated 13 August 2026 08:03 and work/myharmony/compiled-600/Result.EzHex 08:04, and that compile's container is calibration_h600's byte for byte. The second account compiled only Harmony One configurations, so its 700's answer has no configuration to be compared with. The decompiled client under work/myharmony/src/ does not name the setting at all.

Since the stated 20 is also the default, the calibration case shows the value arriving in the file and not a choice: nobody is known to have set it. What it fixes is the units, seconds, and the field. The two compiled configurations with 8 and 10, the 650's and h600_config's, come from remotes whose settings nobody saved.

The pair of timers

Among base slot 12's timers, section 43, two on every arch 14 user configuration queue a list whose first instruction is 1F E910, section 73's field splitting instruction. The three firmware embedded arch 14 containers, h700_gspm and the two safe mode images, have no timers at all. Their durations:

configuration the pair, index and seconds
h650_config_region 1: 8, 3: 10
h600_config 1: 10, 3: 10
calibration_h600 1: 20, 3: 10
h700_config, h700_config_2 5: 10, 7: 10

The two are one light with two durations, chosen by a test. On the 650 list 10C1 is [71 8009, 7F 0394, 7F 0C15] and list 10C2 is [71 8009, 7F 0B95, 7F 0859]: each tests state variable 9 and takes one of two arms, and in both the first arm reaches a list starting timer 3 and the second a list starting timer 1. Every one of the four lists first runs list 02F5, which cancels timers 0, 1 and 3, and 1F E90C; the two under 10C2 add 1F E918. The same two callers are on h600_config and calibration_h600, and on the 700 for timers 5 and 7, where timer 5's starting list is also reached from a list testing variable 14. What variable 9 holds is not read.

When timer 1 expires on the 650 it queues list 0DEE, [1F E910, 7F 0708]. List 0708, [1F FB00, 7F 1027], is also timer 2's own, and it loads the byte register with 0 and runs 1027, [71 8011, 7F 1026, 1F EB02]: if variable 17 is 0 it runs 1026, [1F E903, 1F EB00], and otherwise it starts timer 2, which comes back to the same test two seconds later. Timer 0 queues [1F E900, 3F F101]. So after the light's own timer expires there is a two second poll on variable 17 and then a further ten seconds before 1F E900. What the 0xE9 operands select is not read, and the screen was seen to go dark at about timer 1's expiry, so what the ten seconds after it do was not checked by eye.

The same pair on two older architectures

The same shape is on every arch 8 and arch 10 user configuration whose timers read, nine of them, the Harmony 880, 885, 890 and 895: two timers queueing a list that opens with 1F E910, the higher one at 10 seconds on all nine and the lower one at 20 on five, 10 on three and 5 on one. So across fourteen user configurations on three architectures the higher of the pair never moves and the lower one does, which is the shape a user setting would leave. Nothing there is measured, and no firmware for either architecture is in the lab. The Harmony 525 has one timer per configuration whose list opens with 1F E910, always 1 second, and the timer that differs between its two configurations, 10 and 20 seconds, queues 1F E900 directly; whether that is its screen light is not checked. The Harmony One has no such list.

The measurement

Two writes to the 650 with packages/codec/bin/set-timer.ts, two bytes each, the duration and the trailer checksum, in the blocks at 0x060000 and 0x110000, each read back identical:

timer 1 the screen, timed off the cable
8, as Logitech compiled it dark after six or seven seconds
20, the first write lit for about 20 seconds
10, the second lit for about 10 seconds

So timer 1 is how long the screen stays lit, on the Harmony 650, and the calibration case agrees with MyHarmony's GlowTime in units and in the field it lands in. Timer 3, the other arm, was not changed, so when the remote takes that arm is unread.

Once, and not again: a black screen

After the first write, of 20, the remote was unplugged and its screen stayed black until the batteries came out. h650_glow20_region, read afterwards, differs from h650_post144_region in exactly the two bytes written, so the configuration was intact. After the second write, of 10, the same unplugging left an ordinary screen. One occurrence in two writes of the same shape, and nothing here says what it was; it is recorded so that a second occurrence can be counted rather than rediscovered. The Harmony One's unexplained stranding after idling on USB is the nearest known case and is not evidence that this is the same.

The rule the reader uses, scored

screenLightTimer names the lower index of the pair. On arch 14 the two timers differ on two configurations, the 650's reads, where it is measured, and calibration_h600, where 20 is the default; the lower index is right on both and the higher wrong on both. So is the rule "the one that is not 10", which the two cases do not tell apart. On h600_config and both 700 configurations the pair holds 10 and 10, so the index the reader gives there is the rule's and not a measurement, and the seconds are right whichever is named. A structural rule, the second arm of the variable 9 test, picks the same index on all four compiles and is not implemented.

Scope, decision 16

Measured on the Harmony 650 alone. On the Harmony 600, excluded from writes, the calibration case agrees and nothing more. On the Harmony 700 the pair is present and which one is the light is not established. On arch 8 and arch 10 the pair is present and unmeasured, and screenLightTimer answers nothing there, deliberately, until it is checked. On the Harmony 525 and the Harmony One the pattern is not the same and is not read. The firmware was not read on any architecture.

Sources

The seven saved GetRemoteSettings answers, GET_UAD_Settings and GetProductCapabilities, and the decompiled client, all Logitech's; the four arch 14 user configurations, the nine arch 8 and arch 10 ones, the three 650 reads and the two write journals; sections 43 and 73. The firmware was not read.

Falsification

A write of timer 1 on the 650 that does not move the screen time; a configuration compiled with a GlowTime somebody chose whose lower timer of the pair differs from it; or an arch 14 user configuration with a number of such timers other than two.

The reviewers

The blind re-measure reproduced every duration, list and count above, the two bytes between the reads, and the file dates, and found the default of 20 and the second account's 700 answer, both now above. It saw the reader's docstring by accident, which it reported, so it was not fully blind on which timer was claimed. The prose audit found this section counting three writes where there were two, stating the saved answers as three and then undercounting where GlowTime appears, "only compiled one with a 20" unscoped where arch 8 and arch 10 carry it too, the pair claimed for firmware containers that have no timers, "all that is known" about timer 3 where the callers show the two arms, a skipped list in the chain, a vacuous "every block past it" in section 291, a todo tick resting on less than its item, and two test titles and an off arch 14 assertion that could not fail. Each is corrected.

Where it lands

  • packages/codec/src/tables.ts: screenLightTimer and SCREEN_LIGHT_STEP.
  • packages/codec/bin/set-timer.ts: a timer's duration changed, read back and checksummed, the sibling of set-delay.ts.
  • packages/codec/test/sections.test.ts: the index and the seconds on seven arch 14 containers, the pair counted on every arch 8, 10 and 14 user configuration, one on the Harmony 525 and none on the Harmony One.
  • packages/lab/src/index.ts, tests/lab.py, packages/corpus/bin/write-config.ts and both golden lists: h650_glow20_region and h650_glow10_region, the second the two bytes again and what the 650 holds at the end of this section.
  • docs/config-format.md, section 43's open question, todo.md and docs/status.md.

Section 291 | the archive | section 293. Section 292 of the findings archive, which is frozen; the reference holds the current answer. The archive on GitHub.