295. A Harmony 700 installs its firmware from a staged copy in external flash, and one stuck in safe mode was repaired by asking it to install its own

A second hand Harmony 700 arrived showing the safe mode screen at every start. It is on the bench as the unit h700, arch 14, skin 66, flash 15:1C, and its version block said firmware 2.3 and software type 4. Everything below was read off it before anything was sent, and the one thing sent is the second half of Logitech's own install sequence.

Why it was in safe mode

The safe mode image at internal 0x1000 is version 2.3, 29888 bytes, and verifies. The application at internal 0x9000 is version 2.5, states 71552 bytes, and does not verify: stored 0x99E2, computed 0x2D92. The one 1 KiB page of program memory at 0x10000 to 0x10400 is erased and the pages either side hold code, read twice. The same region read on the Harmony 650 has code in that page and its application verifies, so the hole is the remote's and not the read's.

The previous owner's configuration at 0x030000 was intact, 974009 bytes, every structural check passing, so the configuration was not the cause.

Why Logitech's software could not repair it

  • MyHarmony checks for newer firmware before a sync, and once a latest version has come back, RemoteUpdateManager.IsFirmwareUpgradeRequired returns true for FirmwareType.SafeMode without asking anything else. Which service it asks depends on the product: the software update service only when the product declares SupportsProvisioning or SupportsCertificateActivation, or is a Harmony 350, and skins 66, 71 and 72 declare neither in GetAllProducts. So for this family it takes WebRemoteManager.CheckLatestFirmware, whose files live under files.myharmony.com, and the file name it asks for is unread. The software update service does answer 404 for skins 66, 71 and 72 on both channels, where skin 104 answers 200 with the same key, but that is a route MyHarmony does not use for them, so it says nothing about why the sync failed. Not established: whether Logitech still serves firmware for this family, and whether the firmware step is where MyHarmony's sync fails. This bullet said both were the update service's 404 until reviewer 2 read the branch above it, the same day.
  • Harmony Desktop synced a configuration: the configuration region holds a new compile of the account afterwards, 1070416 bytes, and both internal pages read afterwards are byte for byte the arrival reads, so it wrote no application into the processor. What it did to external flash from 0x000000 is not known, because that range was first read after the sync: the staged 2.5 application there, and the embedded configuration at 0x020000, which is byte for byte the 2.8 package's region 3, may be older than the sync or written by it. Danny found its hidden recovery menu and nothing in it acted on this model.
  • The server side works: a compile requested for the 700's account record succeeded and holds the same devices and activities, work/myharmony/compiled-700/ in the lab.

How an arch 14 remote installs firmware

Logitech's firmwareupgrade.xml for skin 66, in Harmony Desktop's mirrored templates, names the regions and the sequence. Region 2, the application, is written to external flash at 0x000000, the embedded configuration to 0x020000, the bootloader and safe mode are 0xFE0000 and 0xFE1000. After the write it sets the update status, WRITE_MISC selector 6, to code.update.new, 2, reads it back, and restarts the remote with the escape's 0x02. So the host never writes the application into the processor; the remote copies it in.

The safe mode image does the copy, read on the 700's 2.3 image:

  • 0x02074, in its start up sequence, calls 0x02B90.
  • 0x02B90 reads the status through 0x07E6E, which returns data memory 0x100 for index 0. It treats 4 as 2 and 7 as 6, and returns unless the value is 2 or 6.
  • It reads the three bytes at external 0x000004, the image's length less 8, adds 8, and clamps the result to 0x15C00, so the copy ends at internal 0x1EC00, below the settings store section 282 found at 0x01EC00 and the identity block at 0x1F400.
  • It erases internal program memory in 1 KiB pages from 0x9000 through the routine at 0x07CBA, then copies two bytes at a time from external flash into the holding latches, 0x07CD6, committing every 64 bytes through 0x07CEC.
  • It stores 0 back into the status through 0x07E7A.
  • Afterwards 0x027DC compares the application's stored checksum with one computed over internal 0x9000 onward, and on a match the start up jumps to 0x900A, the application. That comparison failing is what kept this remote in safe mode.

The status byte's command is not the general misc shape. The safe mode image's WRITE_MISC parser reads the packet's bytes in order into 0xD09, 0xD0B, 0xD0A, 0xD0D and 0xD0C, its selector chain sends 6 to 0x039B6, and that arm stores 0xD0B as the address and 0xD0A as the value. So the value is the packet's third byte after the command byte, the fourth in all, and this project's writeMiscRequest, which sends a sixteen bit address and value, would have stored the address's low byte. The template's own bytes are A3 06 00 02 and B2 06 00, and those are what updateStatusWriteRequest and updateStatusReadRequest build.

The image length is three bytes. The Python reader, src/harmony/firmware.py, takes offset 4 as a sixteen bit size and offset 6 as a family byte, 0x00 on arch 12 and 0x01 on arch 14, and recovers the length by trying every candidate. The safe mode image reads offsets 4 to 6 as one number, so that "family byte" is the length's top byte. The byte never told two families apart, and the image that shows it is the Harmony 350's: it is not arch 14 and it carries 0x01, because it is 73472 bytes. On the seven application images in the lab, the Harmony 350, the Harmony 600's complete image, the Harmony 650's two, the Harmony 700 2.8 and its bench unit's staged 2.5, and the Harmony One's 3.4, the three bytes plus 8 are the length whose checksum verifies, and byte 6 is 1 on the six over 64 KiB and 0 on the One's 60050. The arch 14 safe mode images refute the family reading more directly: the 600's and 650's 0.2, 24320 bytes, and the 700's 2.3, 29888, all carry 0 there. Section 196 had read the 350's 0x01 as sharing the arch 14 family and is corrected in place. Trying candidates is ambiguous where the remote is not: a synthetic image repeating every 256 bytes verifies at two lengths. packages/usb/src/firmware.ts reads it the remote's way and the Python reader gains stated_size; its recovered sizes on the real images are unaffected, since on each of them only one candidate verifies. tests/test_findings.py and tests/test_harmony_350_firmware.py assert the three byte reading on the application images, packages/usb/test/firmware.test.ts on the staged 2.5 and the three arch 14 safe mode images.

The repair

The remote's external flash at 0x000000, read after the Harmony Desktop sync, held a 2.5 application, 71552 bytes, verifying, and differing from the installed copy in exactly that page. How the hole came about is not established: the install routine erases every page before it copies any, so an interrupted copy would leave everything after the break erased rather than one hole with code after it, and a page whose programming failed or a later erase of that one page both fit. So the repair needed no firmware from anywhere and no flash write from the host: set the status to 2 and restart.

packages/usb/bin/reinstall-firmware.ts --unit h700 --commit did that, after a dry run, behind HARMONY_ENABLE_WRITES=1 and a new door, HARMONY_FIRMWARE_REINSTALL=1. It read the unit's identity against the lab record, the software type, and the staged image, which the rail checks itself; sent A3 06 00 02; read back 2; and restarted the remote. It came back as firmware 2.5, software type 0. The internal pages read afterwards differ from the arrival reads in 1005 bytes, all in the page at 0x10000, which now equals the staged bytes; the bootloader, the safe mode image and everything above the application are byte identical.

The package that would have been wrong

The one 700 firmware package in the lab, the 2.8 .hfw from a repair site, states two different flash parts: its Region_2.EZUpgrade header's INTENDED block says 0x14:0x1C for both software types, and its Data.xml says 0x15:0x1C for skin 66, which is what this remote and the second 700 whose configurations are in the lab carry. Which of the two a client acts on is unread, since nothing in MyHarmony calls EZUpgrade.Intended(). Reinstalling the remote's own build avoided the question.

Scope, decision 16

  • Read: the install routine and the status byte handler on the Harmony 700's 2.3 safe mode image. The routine's status normalisation, 4 read as 2 and 7 as 6, is one byte pattern that does not depend on where a build put its variables, and it occurs once in each of the three arch 14 safe mode images, at 0x02B9C on the 700 and 0x01A8C on the 600 and the 650, and in none of the application images, the staged 2.5 or the Harmony One's internal pages, which fits: arch 12 runs its application in place and has no staging copy. On the 600's and the 650's images the routine it sits in starts at 0x01A80 and is called once, from 0x0107E. The 0x15C00 clamp was offered here as a second distinctive step and is not one: the application images compare against that constant too. The 600's and 650's selector 6 handlers, and every safe mode image's escape handler, are unread; the restart was sent to a safe mode image once, on the Harmony 700, and it restarted.
  • Sent: one Harmony 700.
  • Arch 9 (Harmony 525) installs through an EEPROM byte its bootloader reads, section 119, and entering its safe mode destroys the application, so nothing here transfers to it.

Sources checked before the work

Logitech's clients first, per decision 2: MyHarmony's decompiled RemoteUpdateManager for the safe mode branch and the update service query, Harmony Desktop's SKIN66/firmwareupgrade.xml for the sequence and the regions, and the 2.8 package's Data.xml and EZUpgrade header for what it is intended for. Then the firmware, the 700's own safe mode image and bootloader. Then this repository: docs/host-client.md's arch 12 write sequence, which already named selector 6 as an update status byte at address 0, and reference/concordance-notes.md on arch 14's firmware size.

Five claims in the first draft of this section were wrong and were corrected before it landed, by the second reviewer of the finding skill, and each is worth knowing as a shape. The draft said MyHarmony's failure was the update service's 404, from a branch MyHarmony never reaches for this family; that Harmony Desktop wrote nothing but the configuration, when external flash had not been read before its sync; that the 2.8 package is intended for 0x14:0x1C, citing a Data.xml that says 0x15:0x1C; that the 0x15C00 clamp is distinctive of the install routine, when a first match hid the same constant in every application image; and that the hole was a copy that failed on one page, which the routine's erase first order argues against. The blind reviewer re-measured every number above and agreed with all of them, which is the passenger rule again: the numbers were right and the sentences beside them were not.

Falsification

A staged image at external 0x000000 that the safe mode image does not install when the status is 2, an install that writes outside internal 0x9000 to 0x1EC00, or a remote that reads the status from any byte of the packet but the third after the command byte. On the remote, the reinstall not restoring the application, or changing anything outside the damaged page, was run and did not happen.

Where it lands

  • packages/usb/src/firmware.ts: the image header and checksum, read the remote's way.
  • packages/usb/src/rails.ts: ARCHITECTURES_WITH_A_REINSTALL_TARGET, REINSTALL_MAX_IMAGE, the door and assertReinstallAllowed.
  • packages/usb/src/protocol.ts and writes.ts: MISC_UPDATE_STATUS and the two requests.
  • packages/usb/src/remote.ts: readUpdateStatus and requestFirmwareReinstall.
  • packages/usb/bin/reinstall-firmware.ts: the dry run and the commit.
  • packages/usb/test/firmware.test.ts: the images, the repair, the scope, and the rail's refusals.
  • docs/usb-protocol.md, the recovering-a-remote skill, CLAUDE.md and todo.md.

Section 294 | the archive | section 296. Section 295 of the findings archive, which is frozen; the reference holds the current answer. The archive on GitHub.