Skip to content

298. The Harmony 700's 2.8 application handles the update status byte as 2.5 does, and both builds' restart is read

Section 297 left the rail refusing to stage on a Harmony 700 running 2.8 from application mode, because that build's handler for the update status byte, 0x1AB96, was unread, and it recorded that the restart it had sent was to a 2.5 application whose escape handler was unread too. Both are read now, off Logitech's 2.8 image and off the 2.5 application as it sat in the unit's internal flash.

The status byte

2.5 2.8
WRITE_MISC selector chain 0x0C314 0x0C3AA
cases 1, 2, 5, 6, 7, 8, 9, 10, 11 the same
selector 6 0x0C364 0x0C400
the arm MOVFF 0xD5E,0x103, MOVFF 0xD5F,0x102, CALL the same
the store 0x19868 0x1AB96

The store is five instructions on both: MOVLB 1, MOVF 0x102,W, BNZ, MOVFF 0x103,0x100, RETURN. So on both builds A3 06 00 02 puts 2 into data memory 0x100, the byte the safe mode image reads at start up, section 295.

The store is the only direct write to 0x100 in either build. One routine reads it, 0x1985C on 2.5 and 0x1AB8A on 2.8, which is READ_MISC selector 6's, returning 0x100 when its index at 0x101 is 0; the tracer misses that read because its bank tracking stops at the BNZ before it. For writes the tracer reports six sites in each, the store's MOVFF and five whose banks it only infers: a BTG just after an undecodable word, and four MULWFs inside runs of MULWF and NOP, which is a table of small bytes decoded as instructions. All five are data the linear scan walked into. The store has two callers in each, the arm and one more.

The other caller is in the application's start up. It is a routine with one caller, which the blind reviewer followed up from the entry point, and in both builds it clears the restart flag below, calls a routine whose first instruction is BTFSS RCON,4, and only when that returns 0, which is when RI is set and so the last reset was not a RESET instruction, clears 0x103 and 0x102 and calls the store, putting 0 into 0x100. So after the escape's own RESET the byte is not touched by the application, and after any other kind of start, a power on among them, the application clears it. The safe mode image runs before the application either way, so this does not decide whether an install happens; it is what clears a 2 left behind. Section 295 found the safe mode image storing 0 back after its copy, which is the other half. The routine then sets RCON's four flags again.

The restart

Section 97 read 2.8's: the escape's sub-commands 2 and 3 set a flag at 0x6FF, whose one reader puts the top level mode at 0x3A5 to 3, and mode 3 is a wait of 0x01F4, a poll, a finishing call and RESET at 0x1642C. 2.5 is the same code at other addresses:

2.5 2.8
escape handler, mask 0xF0 and compare 0xE0 0x0BCBC 0x0BD52
sub-command chain, 2 and 3 to 0x0BCFC 0x0BD92
the flag 0x1FF 0x6FF
its reader, mode to 3 0x15398 0x16336
the mode 0x754 0x3A5
mode 3 0x15470 0x1640E
RESET 0x1548E 0x1642C

The 2.5 handler is at 0x0BCBC, which is the address section 282 gives for the Harmony 600's and 650's 0.2 builds, and its flag is 0x1FF like theirs, so 2.5 sits with 0.2 in layout there and 2.8 moved. Each chain here starts at the first XORLW after the MOVF that loads the switched variable, 0xD5D for the selector, 0xD07 for the sub-command and the mode variable for the mode, which is how chains.py says a start is found; the cases that come out, 1, 2, 3 and 5 for the escape, are what section 97 reads on 2.8.

One path can replace the restart, found by the blind reviewer: straight after the flag reader, six predicates are called, and if all six return nonzero the mode becomes 2 instead of 3. The first, at 0x15BDA on 2.5 and 0x17252 on 2.8, returns 0 whenever the USB peripheral is enabled and not suspended, so during a session the restart stands. The other five are unread. The wait is 0x01F4 counts of a timer whose unit is unread.

What changes

STATUS_BYTE_READ_ON_APPLICATION is ['2.5', '2.8'] for arch 14, so the staging and reinstall rails admit a Harmony 700 running 2.8 without safe mode. That reopens the way back section 297 said was closed. The 2.5 image the unit arrived with exists only inside its staging reads, the first 71552 bytes of h700_staging_region, which verify and equal what was installed at 0x9000; passed whole the script refuses it, since an image has to verify at its own length. Cut to that length as --image, with a fresh read of the region as --backup, which read-region.ts takes with --anywhere because 0x000000 is outside the configuration region, reinstall-firmware.ts would stage and install it. Nothing was sent to the remote for this section.

A host can reach the same byte another way: WRITE_MISC selector 7 writes any data address, and 0x100 is one. The rails refuse selector 7 on arch 14, ARCHITECTURES_WITH_A_RAM_WRITE_TARGET.

Scope, decision 16

The Harmony 700's 2.5 and 2.8 application builds. The Harmony 600's and 650's 0.2 builds' restart is section 282's; their status byte handler in application mode and every safe mode image's escape handler remain unread, so the rail's safe mode width, section 297, is unchanged. The application list is wider than the reading too: it is keyed by the version string per architecture, so a 600 or 650 reporting 2.5 or 2.8 would pass on a reading made on the 700's builds. The builds read on those two units are 0.2, and the 650's package is 0.4.

Sources checked before the work

Sections 97, 282, 295 and 297; the 2.8 image h700_code and the 2.5 application read off the unit; Logitech's firmwareupgrade.xml for skin 66, for the sequence the reading has to support. The client was not read further: the question was what the firmware does with a packet whose bytes are known.

Falsification

A 2.8 remote in application mode that does not hold 2 in 0x100 after A3 06 00 02, read back with B2 06 00, which the reinstall already checks before it restarts; or one that does not restart on the escape's 0x02.

Where it lands

  • packages/usb/src/rails.ts: STATUS_BYTE_READ_ON_APPLICATION gains '2.8'.
  • tests/test_harmony_700_status_byte.py: both builds, one address table each, the status byte arm and store, the escape to RESET, and the start up clearing path.
  • packages/usb/test/firmware.test.ts: 2.8 allowed for staging and reinstall, and 2.3 in application mode refused, since no application build of that number is read.

Section 297 | the archive | section 299. Section 298 of the findings archive, which is frozen; the reference holds the current answer. The archive on GitHub.