30. The Harmony 650 is arch 14, and it was the third arch 14 sample sitting unopened¶
reference/checksums.md has named three surviving Harmony firmware packages since the corpus was
first written down. Two were downloaded and analysed. The third, the Harmony 650 0.4 package, was
listed with the note "not yet analysed, arch 15" and no copy was ever fetched.
It is arch 14.
How it was established¶
Downloaded from the same archive page as the other two, opened with tools/ezextract.py, and it
has the same two region shape as the 700 package: a Region_2.EZUpgrade of code and a
Region_3.EZHex holding a container.
| evidence | |
|---|---|
code loads at 0x9000 |
loadaddr.find_base returns 36864 with 1595 boundary hits of 1614 targets, against 410 for the runner up. The arch 14 execution base. |
| the code is a firmware image | its own header checksum verifies over all 75392 bytes, version 0.4, entry point 0x1B658 |
| the container says so itself | section slot 1 states architecture 14, and all ten container checks pass |
| the container sits where arch 14 safe mode configs sit | recovered flash base 0x020000, format 1.4, 20 pointer slots, 7115 bytes |
The recovered base is the closure rather than an input: flash_base is derived from end_addr
minus the distance to the end marker, so the file independently agrees with the address the
architecture uses.
Slot 1 is what carries the weight here, because format 0x1400 alone does not separate arch 14
from arch 9. That is the rule stated in docs/config-format.md, applied to a model nobody here had
looked at.
Why it matters more than one corrected note¶
Three arch 14 safe mode configs now exist, from three models. The 600's was read off the device, the 700's came out of its package, and the 650's out of this one. All three are 7115 bytes and their section tables are byte for byte identical, across three firmware versions with three distinct build timestamps. Two samples were the standard here; three models agreeing makes the arch 14 safe mode layout a property of the architecture rather than of a device.
The differences are small and sit where section 24 said they would:
| pair | differing bytes of 7115 |
|---|---|
| 650 0.4 against 700 2.8 | 50 |
| 650 0.4 against 600 0.2 | 77 |
| 600 0.2 against 700 2.8 | 83 |
The 650's and the 600's were built seventy seven seconds apart, on 18 September 2009, which says they came off one generator run for two models.
And arch 12 is now the thin one. Arch 14 has three code images and three safe mode configs; arch 12 has one of each. The architecture with the popular remote is the architecture with the least corroboration.
The container corpus is fifteen samples as of this section, not the thirteen the earlier
sections above were measured on. Two arch 14 safe mode configs joined it after those were written:
the 600's, read off the device in section 24, and this one. Every claim in this document that was
stated on thirteen has been rerun on all fifteen and still holds, so the older counts are left as
written rather than edited, and docs/config-format.md carries the current one. The counts there
are asserted against the sample table in tests/test_gspm.py now, since that is the number most
likely to drift next.
The general point¶
Only three Harmony firmware packages have ever been published, and all three are the MyHarmony
generation. There is no public firmware at all for arch 2, 3, 7, 8, 9, 10 or 15, which is seven
of the eleven architectures concordance names models for and every architecture on Logitech's own
discontinuation list in reference/models.md. For those the only route to an image is READ_FLASH
off a physical remote.
Section 29 | the archive | section 31. Section 30 of the findings archive, which is frozen; the reference holds the current answer. The archive on GitHub.