Skip to content

306. A power press held for a stated time is a frame count the compiler fits to the hold

Corrected by sections 307 and 308, the same day. Section 308 has the rule: as many frames as start inside the hold on the frame lengths Logitech's definition states, which needs no floor at 300 ms. This section's own rule, frames ending inside the hold, holds for the Panasonic power codes and not for the compiler: five other families count the frames that start inside the hold. Its measurements stand; its generalisation does not, and the three families here other than the television's give the same count under both readings, so nothing in this section could have shown it. The heading said "is as many frames as end inside the hold" until then.

2 October 2026, todo L9. Section 305 found one catalogue device whose power codes Logitech's compiler sends seven times, and tied the seven to a one second hold its catalogue states. One codeset could not say what the rule is. This puts four more catalogue devices through Logitech's own compiler, with holds from 300 ms to 15 seconds, plus the section 305 television as the control, and reads the result. Predictions were written and committed first, docs/predictions-power-hold.md, and are scored there.

The route needs no remote. The five devices were added to the first test account's Harmony 700 and Harmony 650 records through the device door, UpdateMultiple, each record was compiled by StartCompileWithLocaleAndSettings and the file taken as a download, and the five were removed again with DeleteDevices. Read back afterwards, every record on the account holds the same device ids and the same activity ids as before; that is the household read, and device settings were not compared. Two of the throwaway records on the second account were tried first and both refused a new device, CanAddAnotherDeviceToAccount, "Cannot add device to the remote attached to the account". All twelve of those records carry the Harmony 525's serial, and that the refusal is about the 525 is a guess: the message names no reason, the device count is under that model's twelve, and the account's one record of another model was not tried.

device family hold ms min repeats frames last frame ends one more would end
Panasonic TX-P42GT30E, PowerOn PanasonicV2 48 Bit 1000 3 7 867.50 ms 1002.12 ms
Panasonic TX-P42GT30E, PowerOff PanasonicV2 48 Bit 1000 3 7 879.68 ms 1016.04 ms
Barco 6300, PowerToggle Magnavox 13 Bit 15000 3 130 14989.70 ms 15105.72 ms
JVC DLA-HD10KU, PowerOn and PowerOff JVC 16 Bit 5000 3 111 4986.80 ms 5031.80 ms
Knoll HDP-1100, on Toshiba 32 Bit 800 1 8 766.85 ms 874.71 ms
Knoll HDP-1100, off Toshiba 32 Bit 500 1 5 443.25 ms 551.12 ms
Panasonic TX-29AK40F, PowerToggle PanasonicV2 48 Bit 300 3 3 329.05 ms

Ten held records: the television's two codes on each compile, the Barco's one, the JVC's two, the Knoll's two and the TX-29AK40F's one. A frame is what lies between two spaces over 10 ms, the shortest gap between frames here being 20.8 ms and the longest space inside one about 4.5 ms; so the JVC family, a 36.8 ms frame with its header and then 24.2 ms repeats without it, spaced 57.6 ms and then 45.0 ms, counts 111, and the Toshiba 32 Bit family, a 67.65 ms frame and then 11.79 ms repeat frames, spaced 107.9 ms, counts 8 and 5.

Every step of a power action list is a record of its own, and the hold sets how many frames it holds. Such a record has no lead in and no held block, which is the shape of any power step and not of a held one: the Barco's power on step, which states no hold, is record 22 beside the held record 32, with three frames, and the LG television's two power steps on the 650, no hold either, hold two frames each, a frame and one repeat frame, which is what that family's ordinary press sends. The ordinary press of the same command keeps a record of its own with its lead in and its held block, for all seven held commands.

The rule that fits all ten, and which section 307 shows holds only for the Panasonic power codes: as many frames as end inside the hold, the gap after the last allowed to run past it, and never fewer than an ordinary press sends. On the nine records above their device's minimum, the last frame ends inside the hold and one more at the same spacing would not. The tenth, the 300 ms Panasonic, holds three frames where two end inside 300 ms, which is what its ordinary press sends. That floor rests on that one record and is not separated from two other readings: a power step with no hold has the same three frames, so the hold may simply have been too short to change anything, and counting the frames that start inside the hold gives three there with no floor at all. The floor is in an ordinary press's frames rather than in pressMinRepeats frames, since the LG's minimum of 1 is two frames in its family.

What separates "end inside" from "start inside" here is the television alone, and section 307 found the same three Panasonic power codes counting ends on three more codesets while five other families count starts. Counting frames that start inside the hold gives 130, 111, 8, 5 and 3, matching six of the ten records, and 8 on the television's four, where seven are sent. Its eighth PowerOn frame would end 2.12 ms past the second and its eighth PowerOff 16.04 ms past, so the distinction is real and rests on one codeset with a thin margin on one code. Counting whole copies with their gaps, which section 305 could not tell from either, gives 129 for the Barco, 110 for the JVC and 7 and 4 for the Knoll, one short on five of the nine records above their minimum; it agrees only on the television. Rounding up gives 8 on the television. The predictions took the catalogue's Pronto first section as one copy, which gave 86 for the JVC, whose compiler repeats the shorter frame of its second section, and 3 for the Knoll, whose first section holds two frames.

The hold belongs to the device and not to an activity. The television on the 700 was in no activity there and came back at seven, its two held blocks word for word the ones section 305 read on the 650 and the 600. On the 650's own compile the television's blocks are the same set as before, at other record indices, 4 and 54 against 9 and 10.

What the television itself needs, heard at the bench

The Panasonic TX-P42GT30E is on the bench with its original remote, and two runs with the Flirc receiver put numbers on both ends. Its own remote's power button sends the catalogue's PowerToggle, once or twice for a tap and then again every 134 ms for as long as it is held: twelve bursts of 2, 2, 2, 8, 3, 2, 48, 2, 13, 2, 8 and 3 frames, median interval 134 ms over 83 intervals, against the Harmony's 134.6 ms. The receiver's timestamps are the host's and jitter from 112 to 151 ms.

The television switches on from four frames and not from three. With it off before every step: a tap, one frame, did nothing; about half a second, four frames, switched it on; eight and eleven did too; the Harmony 650's device mode Power On, an ordinary press of three frames, did nothing; and the 650's activity, the held record's seven frames, switched it on. Four frames last about 0.46 s from the first mark to the last, so the catalogue's one second, seven frames and 0.87 s, is close to twice what this unit needs. Switching it off took a tap of two frames each time. Whether the television came on is what was seen at the bench, not an instrument reading, and it is one unit.

The device mode consequence is practical: on this television a power key that sends the ordinary press does nothing, so a device page's power key wants the held record, which Logitech's own compile did not give it.

Which key that was, added on Danny's word and checked against the configuration: the Power On pressed was the soft key beside the display on the television's device page, not the keypad's power button. In the 650's configuration the television's device mode binds its three power commands to screen keys only, PowerOn, PowerToggle and PowerOff, each an ordinary press record with a held block, and no keypad key sends any of them, which agrees with the physical power button doing nothing in device mode on this remote.

Independent closure and calibration

The holds and minimum repeats are read out of the archive's schema version 2, the frames out of Logitech's compile, and the two meet in nothing but Logitech's database. The television was meant as the calibration case, its count known before; it turned out to be the only point separating "end inside" from "start inside", so it is a measurement the rule rests on rather than a check of it.

Scope, decision 16

Compiled for a Harmony 700 and a Harmony 650 only, arch 14. What Logitech's compiler emits for a held power press on arch 12 (Harmony One) or any other architecture is unchecked. Four protocol families, five devices, ten held records.

Sources checked before the work

The archive, for every device's holds and minimum repeats; section 305, which found MyHarmony's client sets no power action duration, so the compile is the only source of the count; and the corpus, where the PlayStation's codes at 36 and 30 copies stand with no duration and stay unexplained.

The two reviews

Run on the whole diff before the commit. The blind re-measurement found the same ten records, the same counts and the same rule, and raised that the 300 ms record cannot tell a floor from a hold too short to matter. The sentence audit re-measured every figure in the table and found nothing wrong in it, and found nine things wrong around it and some smaller wording, all corrected above: the record counts disagreed with each other, "five more devices" counted the control, the floor was stated in pressMinRepeats frames although the LG's power steps contradict that, the separate record was attributed to the hold although every power step has one, "settles" overstated a rule that the television alone separates from rounding up, the Pronto explanation was wrong for the JVC, "frame" was used for a spacing, "all refuse" was two of twelve with a guessed cause, and the test claimed a shape check over groups it did not cover.

Falsification

A held power record whose frame count is neither an ordinary press's nor the number of frames that end inside its hold, on any device or architecture. Met the same day: section 307's Pioneer holds 23 frames where 22 end inside its hold and an ordinary press sends 3, and five more records like it. A hold shorter than one frame on a device whose ordinary press sends more than one frame would separate the floor from counting starts.

Where it lands

  • packages/codec/test/irframe.test.ts, the held frame test: holds from the archive, frames from the two compiles, every pinned record's first frame matched against the catalogue's code for its command, the nine above their minimum found again by shape, the 300 ms record tied to its command's ordinary press, and the whole copy and start readings counted where they fail. Its control, the 300 ms record pinned to a digit's record instead, fails on the catalogue match.
  • packages/codec/test/irframe.test.ts again, twice more: the original remote's taps and holds and their spacing against the Harmony's, and the threshold run's frames per step with what was seen at the bench.
  • docs/config-format.md, beside how many times a press sends the code.
  • The two compiles are lab fixtures h700_power_hold_compile and h650_power_hold_compile, out of the corpus since no remote ever held them, and in the golden vectors.

Section 305 | the archive | section 307. Section 306 of the findings archive, which is frozen; the reference holds the current answer. The archive on GitHub.