Skip to content

308. A held power press holds as many frames as start inside the hold, on the frame lengths Logitech's definition states

2 October 2026, todo L9. Section 307 left three readings, none tested ahead. The long gap and the device record fit every held record, each needing an ordinary press as a floor at 300 ms; the stated length fit every one but the JVC's two. A fourth round, one compile, was chosen so that each reading predicted, on one device, a count the other two did not, predictions committed first in docs/predictions-power-hold.md, the three devices added to the first test account's Harmony 700 record, compiled, and removed again, the account's 78 ids identical afterwards.

device step family hold ms stated length long gap device record compiled
Panasonic TX-D37LT84F on, PowerOn PanasonicV2 48 Bit 2500 18 19 19 18
Sony KE-50MR1E on, PowerOn Sony 12 Bit 1000 23 22 23 23
Sony KE-50MR1E off, PowerOff Sony 12 Bit 1000 23 22 23 23
Thomson 25DT60H on, "1" Philips RECS80 11 Bit 1500 13 13 12 13

The bold count is the one each row was chosen for. The stated length was right on all four and each other reading was wrong on the row chosen to test it. The TX-D37LT84F's PowerOn is the bench television's code byte for byte, on a fifth codeset, and at 2500 ms both of section 307's counting rules give 19, with at least 17 ms to spare on the compiled lengths, so its 18 is neither: it is the stated length alone. Its PowerOff, held 1500 ms, holds 11, which refutes the device record reading as well but only by 0.1 ms, its twelfth sent frame starting at 1499.90 ms.

The rule. A held power press holds as many frames as start inside the hold, where every frame is given the length the protocol definition states for it rather than the length it is sent at: its segment's TotalLength where the definition gives one, and otherwise the segment's header, its trailer and every bit at the mean of its two cell lengths. A frame is the definition's KeyCode: its Start segments, then its Repeat for as long as the hold lasts, and an opening segment with no payload is part of the frame after it. That last clause was added after the compile, to recover the JVC, which the rule as predicted missed by one: its definition opens with a CodeSegments entry JVC 16 Bit KeyCodeStart, 8400 and 4200 us and no payload, so its first frame is stated at 57.6 ms and every later one at its TotalLength of 45 ms. Those are exactly the compiled spacings section 306 measured, and the 12.6 ms is a number the definition states rather than one fitted, so the closure is real while the shape of the clause is fitted. Without it the rule gives 25 of 27.

That one rule gives all 27 held records of the six compiles in four rounds, ten families and sixteen devices, and it is why section 307 saw two groups. On 13 of the 27 records, eight families, the stated length and the sent length agree to 0.01 ms, since the compiler renders a code from the same definition; the Memorex family is sent 1.1 ms short of its stated 109.9 ms and gives the same count either way. On those 14 the rule and counting sent starts cannot be told apart. The Panasonic power codes are sent 134.6 and 136.4 ms apart against a stated 143.3 ms, 7 to 9 ms short, their 48 bits being 32 and 34 of them the shorter cell, so fewer stated frames fit, which section 307 read as counting the frames that end inside the hold. The floor section 306 needed is not needed either: the TX-29AK40F's three at 300 ms is ceil(300 / 143.31).

The mean is preferred and not identified. Giving every bit its shorter cell gets 12 of the 27 and its longer cell 18. Eleven records do not depend on the bit length at all, the ten in families that state a TotalLength and the Barco's, whose two Magnavox cells are both 1780 us; the shorter cell adds the TX-29AK40F at 300 ms and the longer adds the seven Panasonic records at 1000 ms. On the Panasonic family the holds bound the length to at least 142.86 and under 147.06 ms, anything from 24 to 28 long bits out of 48, and the mean, 143.31, sits 0.45 ms above the bottom, which the seven records at 1000 ms set: a stated length 0.32% shorter flips all seven.

The evidence out of sample is one record. The stated length and the mean cell were read off records already compiled, the bench television's seven among them, so those are fitted points and not calibration. What the fourth round predicted ahead and only this reading got right is the TX-D37LT84F's 18 at 2500 ms, plus its PowerOff by 0.1 ms; the Sony and the Thomson refute the other two readings but agree with counting sent starts. And one reading the round did not exclude: the Panasonic power codes holding as many whole copies as fit, floor(hold / sent spacing) with an ordinary press as a floor, and every other family counting starts, also gives all 27, 18 at 2500 ms included. The stated length wins on being one rule with no floor and no family exception, not by elimination. A family whose codes are not complemented and are sent well away from their mean length, held long enough for the two to part, would test it.

Independent closure and calibration

The lengths come out of Logitech's protocol definitions in the archive and the counts out of their compiles, but on 14 of the 27 records the compiler sent exactly what the definition states, so only the Panasonic records separate the two sources. The JVC's first frame is the closure: the 12.6 ms by which its compiled first spacing exceeds the rest is stated in its definition. There is no calibration case in the strict sense, as above.

Scope, decision 16

Compiled for a Harmony 700 and a Harmony 650, arch 14, and nothing else. Ten families, sixteen devices with a held step, 27 held records of the test devices; the account's own devices on those records are not examined. Three of the families carry a toggle bit, the Magnavox, RECS80 and Thomson ones, five records. Families with several repeat segments or more than two cells are unmeasured, and whether a hold shorter than an ordinary press can send fewer frames is still unanswered, which no record needs.

Sources checked before the work

The archive's protocol definitions, all of IRSegments, CodeSegments and KeyCode, sections 305 to 307 and docs/predictions-power-hold.md. Section 305 found MyHarmony's client sets no power duration, so the count is the service's compiler and no client or firmware holds it.

The two reviews

Run on the whole diff before the commit. The blind re-measurement found the same records and, from the definitions alone, the same rule, 25 of 25 rows, and named its weakness: the mean rests on one family. The sentence audit confirmed the 27 and found sixteen things wrong around them, all corrected here or in place: "four compiles" where there are six in four rounds; section 307 said to have left three readings that fit every record when the stated length missed the JVC; section 307's JVC sentence and falsification clause uncorrected; the 12 and 18 attributed to the wrong records; "identified" for a window; "most codes" for 13 of 27; a calibration claim for fitted points; the floored whole copy reading not mentioned; toggle families called unmeasured; "fewer frames" stated for every Panasonic record where the TX-29AK40F gets 3 either way; "about 9 ms" for 7 to 9; the PowerOff said to separate nothing; a control described and not in the test, and per row match counts not asserted, which left the marks clause untested; section 305's test comment stating section 307's reading; section 305's whole copy explanation in docs/status.md; and the test's title claiming every held record when it lists the test devices'.

Falsification

A held power record whose frame count differs from the frames that start inside the hold on the definition's stated lengths. A family whose codes are sent well away from their mean length, held long enough, would separate this from counting whole sent copies.

Where it lands

  • packages/codec/test/irframe.test.ts, the stated length test: all 27 held records of the test devices in sections 306 to 308, each found by its catalogue code, marks and spaces both since the Sony family spells its bits in its marks, how many records match asserted per row, each count computed from the definition and required to match, and three controls counted: the shorter cell 12, the longer 18, the lead in left off 25. Dropping the marks from the match fails it.
  • Sections 306 and 307 corrected in place.
  • docs/config-format.md, the held power entry, restated.
  • The compile is the lab fixture h700_power_hold_compile_4, out of the corpus and in the golden vectors.

Section 307 | the archive | section 309. Section 308 of the findings archive, which is frozen; the reference holds the current answer. The archive on GitHub.