Skip to content

326. The two row device list on a Harmony 600, 650 or 700 is compiled and nothing enters it

Date: 3 October 2026. Status: confirmed in the configurations and in five firmware builds; not checked on a remote, and nothing here needs a remote to check it.

Asked for by todo-compile-650.md 2.3. Section 312 composed a new device list page where the last one is full, and on the Harmony 650's six device configuration the only list that opens a page for a seventh device is the one laid out in two rows. Whether anybody can see that page decides what 2.3's hardware check is.

Sources, checked before the work. Sections 36 and 37, which named the event map and the mode table; 285 and 294, which found the two row list and said it is entered by neither record of an activity; 289 and 316, the activity menu; 304, the command states; 311, the mode stack and the mode switch on the 600; 312. The firmware images h600_code_complete, h650_bench_code, h650_code and h700_code, and the Harmony 700's 2.5 build cut out of the bench unit's internal flash as read before section 297. The manuals for the 600, 650 and 700 in the lab's Docs, whose text describes one device list, reached with the centre button from an activity or the activity menu, and paged with the arrows on the 650; a read only investigation before this section looked at their pictures, which draw a corner list only, and that half was not repeated. Logitech's client was not read for the mode question, since the firmware answers it; for the host route below, the classic client's own protocol constants were read, which name a queued action as WRITE_MISC selector 3, a selector arch 14 does not service, section 19.

Every compile has exactly one, and nothing in the file names it

configuration two row list pages event map block corner lists row menus
h600_config 166 2 14 to 43 4 9
calibration_h600 167 2 14 to 43 3 7
h650_config_region 179 3 14 to 43 4 11
h650_panasonic_config 226 3 14 to 43 5 13
h650_power_hold_compile 325 4 14 to 43 5 17
h650_power_hold_compile_2 337 4 14 to 43 5 17
h700_config, h700_config_2 283 3 19 to 48 6 13
h700_28_config_region 166 3 19 to 48 3 11
h700_power_hold_compile 297 4 19 to 48 3 17
h700_power_hold_compile_2 295 4 19 to 48 3 17
h700_power_hold_compile_3 295 4 19 to 48 3 17
h700_power_hold_compile_4 297 4 19 to 48 3 17

The thirteen are section 312's, every arch 14 compile the lab holds once; h650_seventh_base, which is h650_panasonic_config with section 309's one byte edit and is what the bench Harmony 650 held when section 312's seventh device was written, reads the same as its parent, mode 226. A two row list is a mode whose page binds both buttons of a row, scans 2 and 8, to row lists entering one device's mode; a corner list is any other mode whose rows enter two devices or more; a row menu is any other mode binding scans 2 and 8 to two lists of identical body that enter no device, which is the activity menu, 13, and the two delay menus every device has, 166.

On every one of the thirteen and the seventh base:

  • No 0x7E names it. An instruction is stored as operand low, operand high, opcode everywhere one can sit, an action list, a tagged list entry, a timer and a screen program's queue instruction, so the three bytes lo hi 0x7E are searched over the whole container rather than through a reader. The count is 0. A coincidental match could only make a mode look entered, so zero is the strong direction. The control is the corner lists and row menus of the same files: all 53 corner device lists and all 179 row menus of the thirteen, 232 lists, are named by at least one 0x7E, 58 and 192 with the seventh base. It is not a control for the firmware's own screens below the event block, two bullets down.
  • No event map entry names it. The event map's thirty values and its fallback are 14 to 43 on the 600 and 650 and 19 to 48 on the 700, contiguous, section 36, and the list sits far above.
  • It is the only such mode above the event block. Every other mode above the block is named by an 0x7E somewhere in its file. Below the block sit the firmware's own numbered screens, "Update Successful", the learning prompt and "Unable to charge batteries" among them, and several of those are named by no instruction the readers walk either, six to eight per configuration; how they are shown is not read here. The byte search says little down there, since a small mode number followed by 0x7E turns up by coincidence: it finds no enter for between none and three of them per configuration.
  • Nothing shares its pages with another mode, neither a page list nor a program, so its rows reach no screen through a mode that is entered.
  • No configuration instruction builds one at run time. 0x7B, and any opcode from 0x1F to 0x3E whose operand's high byte is 0xF7, assemble an instruction out of a variable, sections 34 and 72; neither occurs in any of the 441215 instructions the readers walk over the fourteen files. That covers the configuration's own instructions only. The firmware pushes instructions of its own onto the queue as well, through the enqueue below from eight call sites and through a second push routine, 0xE650 on the 600's 0.2 build, from five; two of those sites, 0x1251A and 0x16336, push an instruction copied out of data memory, a table walked from 0x3B7 to 0x3D5 and the three bytes from 0xD3D. None of them was traced to what fills those bytes.

It is wired as a device list in every respect a key can see: a page per two devices, each device on both buttons of its row, "Activity" as the bottom word on every page, and its record's one entry the centre key's press, tag 0x99, running the same 0x72 as every corner list's centre key. The corner lists' records carry one entry more, tag 0x2D running a 0x73, which the two row list's lacks; what it does is not read here.

The firmware enters a mode from three places

On the Harmony 600's 0.2 build the routine that makes a mode current is 0x147BA, and it has four direct callers, a CALL, RCALL, GOTO or branch whose stated target it is:

caller what it hands over from
0x0E8FA the operand of the instruction being run, 0x2B2 the 0x7E handler, right after the opcode is compared with 0x7E
0x0F26E the mode stack's top entry, through FSR0 0x07 with operand 0xFFFC, the pop, section 311
0x14C10 the matched entry's value, 0xD1A the event map walker at 0x14BA4, section 36
0x14C42 the fallback, 0xD14 the same walker when no key matches

Those four are the only direct writes of the argument pair 0xAD/0xAE, each writing the low byte from its source and the high byte from the source's high byte, and the current mode, 0xA8/0xA9, is written at 0x14816 from the argument and nowhere else but the two resets to 0xFEFE, at 0x14802 inside the switch and at 0x1477C in a routine of its own just before it. The mode stack is pushed by 0x07 0xFFFD from the current mode itself, so it can only hand back a mode that was already current. So a mode the firmware can make current is one an 0x7E names, one the event map names, or one that was current before, as far as the code states its targets, and the two row list is none of them. Two things this cannot see: a computed jump into the switch, which no list of callers shows, and a write through FSR, since the tracer sees MOVFF and banked access only, so "nothing else writes" is about direct writes.

The same shape is on every arch 14 application build in the lab, located by the routine's first six bytes, which occur once in each:

build mode switch its four callers current mode argument
Harmony 600 0.2 0x147BA 0x0E8FA, 0x0F26E, 0x14C10, 0x14C42 0x0A8 0x0AD
Harmony 650 0.2, the bench unit's 0x147BA the 600's 0x0A8 0x0AD
Harmony 650 0.4, the published one 0x1654C 0x0ECD8, 0x0F6B2, 0x169A2, 0x169D4 0x0D4 0x0D9
Harmony 700 2.5, the bench unit's before section 297 0x14AB8 0x0E90C, 0x0F280, 0x14F0E, 0x14F40 0x6E7 0x6EC
Harmony 700 2.8 0x1679E 0x0ECEA, 0x0F6C4, 0x16BF4, 0x16C26 0xF28 0xF2D

On each the argument is written only by the four callers, from the instruction's operand, the stack, 0xD1A and 0xD14, and the current mode only by the switch and two resets. The safe mode images were not checked.

A host can enter it, and that corrects section 19

Command state 0x34 reads three payload bytes and hands them, as an opcode and an operand, to the routine that pushes an action instruction onto the forty slot queue: 0xBEBE calling 0xE628 on the 600 and the 650's 0.2 and 0xE63A on the 700's 2.5, 0xBF54 calling 0xE9FC on the 650's 0.4 and 0xEA0E on the 700's 2.8, decoded out of the sub-command switch with chains.py. Each first calls the routine that hands over the next payload byte three times. That push is the one configuration instructions take: on the 700, section 34's 0x0EA5A reads one instruction of an action list and jumps into 0xEA0E. Section 304 lists 0x34 among the twenty parsed states and left it unread; a version request with a payload selects it. So a host can queue any action instruction, 7E and a mode number included, and section 19's reading that arch 14 does not implement action queueing holds for WRITE_MISC selector 3 and not for the remote: the queue is reached another way. Nothing here has sent it, and isReadOnlyReport refuses it, being a version request with a payload. Command state 0xB1 is a second route, section 304: it writes any byte of data memory, which reaches the argument, the current mode and the mode stack directly. Neither is a route for a person, so the conclusion stands for the keypad and the screen.

What it means for todo-compile-650 2.3

Composing into the two row list matches Logitech, so section 312's calibration stands. But no person can see it, so a page opened there cannot be checked by looking at the remote. The lists a person reaches are the corner lists, which the centre key under "Devices" enters, the idle list when no activity runs and each activity's own when one does, section 294, four devices to a page, so a corner list opens its first new page at the fifth device; that every fourth one after it opens another is arithmetic, not a measurement. The Harmony 650's current configuration has six devices, its corner lists holding four and two, so a seventh fills a page and opens none. 2.3's hardware check needs a corner list going from four devices to five: a configuration for the 650 with four devices, or one whose corner lists are otherwise full, and a fifth composed onto it.

The Help key's "Select device" screen, the picker, is a third kind of device list and is on all thirteen compiles, modes 131, 119, 139, 165, 293, 314, 219, 219, 131, 269, 268, 270 and 282 in the table's order, one page on the two 600 compiles and two on the rest. Its rows run 0x7E directly rather than calling a list, so this section's definitions leave it out of the corner lists, and section 312's composer does not grow it; whether it has to is not answered here.

Section 312, corrected in place

Section 312 listed, as a way to falsify it, a composed fourth page on the 650 that does not page in. Nothing shows the two row list, so that half of its falsification cannot be tested on a remote; it is corrected there, with how the error came about: section 312 grew the one list that opened a page and took for granted that a list Logitech compiles is a list a person can reach.

Scope, decision 16

Arch 14 only: the Harmony 600, 650 and 700, on every compile and every application build the lab holds for them, five builds. The safe mode images were not checked. The Harmony One's device list has no two row twin and was not looked at for this.

Falsification

An 0x7E naming the two row list in any arch 14 compile, an event map value reaching it, a fifth caller of the mode switch or another writer of the current mode in any arch 14 build; or, on a remote, any key or screen sequence that shows a device list two to a page.

Where it lands

  • packages/codec/test/tworowlist.test.ts: the mode numbers, the record list, the zero count with its control, the event block, the one mode above it nothing enters, the shared pages and the run time builders.
  • tests/test_gspm.py, TheModeSwitchTakesItsNumberFromThreePlaces: the switch, its four callers, the argument's four sources with both bytes, the current mode's three writers, and command state 0x34 with its three payload reads, on all five builds.
  • docs/config-format.md under the arch 14 device list, docs/usb-protocol.md, sections 19 and 312 corrected in place, docs/how-a-harmony-works.md, docs/status.md and todo-compile-650.md.

Section 325 | the archive | section 327. Section 326 of the findings archive, which is frozen; the reference holds the current answer. The archive on GitHub.