339. A pass through device is switched on and set to its input, and given nothing else¶
Todo todo-compile-650.md 3.14. MyHarmony lets an activity hold a device with no job, which its
service saves as a PassThroughActivityRole: an HDMI switch the picture only passes through. The
question was what Logitech's compiler makes of one, and whether the composer can build it.
Sources checked: Logitech's compile of the Harmony 650's starting setup, h650_start_config,
whose saved activities state the roles (work/setups/h650-start/replies/); MyHarmony's decompiled
client for the role's name and payload, through the setup builder of todo-compile-650 1.6; this
document, sections 273, 291, 313, 323 and 332. The firmware was not needed: nothing here is a new
instruction, only which instructions the compiler emits.
What Logitech's compile does¶
Kodi kijken holds the LG television on HDMI 3, Kodi to play, and the switch on Input 2 with no role.
Its start switches on the LG, Kodi and the switch, in the saved power on order, and its input list
writes LG_TV_Input 5 and Switch_Input 1, which is Input 2 by the code it sends. Its tag 5 list,
section 313, calls the same input list. Its own device list opens with the LG, Kodi and the switch, in
that order. The keypad map and the working screen send nothing to the switch: the keys go to Kodi and the
LG, and the screen's one item is Kodi's. The other three activities switch the switch off.
Nothing in the file states the role. A display device with no key and no screen item has exactly this shape: TV kijken's LG is switched on and set to HDMI 1 and given nothing else. So a pass through device is recognised only where the activity is stated as MyHarmony states it.
Second sample, inferred: the contributed Harmony 700 configuration (h700_config), whose Watch VCR
switches its A/V switch on last of four, sets its input to 1, lists it fourth and binds it nothing. No
other compile in the lab has its roles captured, so this one is the same shape with the role guessed,
read by hand and not asserted in a test.
What the composer does¶
activityFromRoles takes an activity as devices with roles and an input each and gives the composer's
targets: every listed device on, each set to its input, every other device off, and the keys from the
volume and control roles, section 323. A device with no role is switched on and set to its input and
nothing else, and is reported in passThrough. On the command line it is a --targets device left out
of --roles. Composed from the catalogue onto h650_panasonic_config, Kodi kijken's three devices come
out equal to Logitech's in power on, inputs, off, tag 5, keys, screen and the head of the device list,
and the switch's input value 1 sends Logitech's Input 2 code word for word; left out, exactly those
places change and nothing else (packages/codec/test/passthrough.test.ts).
On the bench¶
One write of the 3.9 bench file with "Switch kijken" composed onto it: the Plasma on HDMI 3 for volume,
Kodi for the rest, the switch with no role on Input 3, so its code differs from Logitech's Kodi kijken's
Input 2 (reads/20261008T095859Z-ir-test-harmony-650-a-pass-through-switch-in-our-activity-and-in-logitech-s.json).
- Starting it: the Plasma's
PowerOn(seven frames), Kodi's power toggle, the switch's power on code, then the switch'sOutputAInput3and the Plasma'sInputHDMI3. - Its own device list sent nothing. Picked again: the switch's
OutputAInput3alone, since its input takes its values from-2and the Plasma's from-3, section 332. - Volume Up went to the Plasma and Play to Kodi; nothing reached the switch.
- Logitech's Kodi kijken from there: the LG's
PowerOn, the switch'sOutputAInput2, the Plasma'sPowerOffand the LG'sInputHdmi3, no power code for Kodi or the switch, which stayed on. Ours again: the Plasma'sPowerOn, the switch'sOutputAInput3, the LG'sPowerOffand the Plasma'sInputHDMI3. - All Off: the Plasma, Kodi and the switch, and nothing else.
The switch's power on record is the one Logitech's compile sends; the bench monitor names that frame
ARC, the first command the catalogue gives its number, and its power off PowerToggle.
Scope, decision 16¶
Measured on arch 14 alone, the Harmony 650, on one compile with the role stated and one with it inferred. The Harmony One and the other architectures are not checked.
Falsification¶
A Logitech compile that binds a key or a screen item to a device saved with a pass through role, or leaves it off in the activity's start; on the Harmony 650, our Switch kijken sending the switch a code on a key press.
Where it lands¶
packages/codec/src/activityroles.ts:activityFromRoles, andActivityRoleNameshared with the setup builder.packages/codec/test/passthrough.test.ts: Logitech's compile read, ours composed against it with the switch left out as the control, and the refusals.docs/config-format.mdunder an activity's key map.
Section 338 | the archive | section 340. Section 339 of the findings archive, which is frozen; the reference holds the current answer. The archive on GitHub.