35. Base slot 13 is the state variable table, and the firmware confirms the section table¶
Section 34 left 0x17E28 as an unnamed lookup that 0x70, 0x71 and 0x72 all index with a
byte. Reading it names a section, places a third opcode, and confirms in code the one claim in this
project that had to be corrected in place.
What 0x17E28 reads¶
A table in RAM at 0x0900, with two halves:
index < threshold: one byte at 0x0900 + index, zero extended to sixteen bits
index >= threshold: two bytes at 0x0900 + threshold + 2 * (index - threshold), little endian
The threshold lives at 0x1EA. So the variables are narrow first, then wide, and how wide a
variable is follows from its index rather than from anything stored beside it.
Where the table comes from¶
The initialiser at 0x17974 positions on config section slot 13 and reads a four field header,
storing the second field into 0x1EA. In the container that section is:
+0x00 u16 count how many variables
+0x02 u16 narrow how many are one byte, and the firmware's threshold
+0x04 u16 wide how many are two bytes
+0x06 u16 narrow again the same number a second time, purpose unestablished
+0x08 u24 entry[count]
Checked on all ten configs: narrow + wide == count, the fourth field always equals the second,
and 8 + 3 * count equals the section's length exactly.
| config | arch | count | narrow | wide | RAM it occupies |
|---|---|---|---|---|---|
| 700 | 14 | 94 | 67 | 27 | 121 |
| 600 | 14 | 74 | 55 | 19 | 93 |
| 525 | 9 | 24 | 23 | 1 | 25 |
| One, programmed | 12 | 46 | 45 | 1 | 47 |
| One, unprogrammed | 12 | 42 | 41 | 1 | 43 |
| 880 c | 8 | 38 | 37 | 1 | 39 |
"State variables" is one of the four subsystems the format's designer named in harmony-decompiler discussion 1, alongside infrared sending, menus and action lists. Two of those four are now named.
The closure¶
Every 0x70, 0x71 and 0x72 index in every config is below that config's own count. That is
already a fit across ten different counts from 24 to 94. But the split is sharper than that:
| opcode | uses | indices |
|---|---|---|
0x71 |
2164 | always below narrow, so always a one byte variable |
0x70 |
146 | always at or above narrow, so always a two byte variable |
0x72 |
501 | either half |
Zero violations, ten configs, four architectures.
Section 34 read the firmware and found that 0x71 compares a byte variable while 0x70 compares
the sixteen bit accumulator. The config data has no way to know that, and it respects the exact
boundary that each config's own header declares. Two readings from opposite ends meeting on a
number that varies per config, 67 on the 700 and 55 on the 600 and 45 on the One.
In six of the ten configs the largest index used is count - 1, so the last variable is live and
the count is a size rather than a ceiling.
Selectors 6 and 7 assign¶
Section 34 left them as "not comparisons". 0x17D0E reads the variable through the same lookup,
adds a sixteen bit delta and clamps against a bound. So 0x70 and 0x71 are one instruction that
either tests a state variable or updates it, and the selector nibble chooses.
The section table, confirmed in code¶
The routine every consumer goes through, 0x10B92, is four instructions of arithmetic:
offset = 4 * slot
offset = offset + 0x0B
seek to the container plus offset
read one byte and discard it
follow the three byte pointer that comes next
That is 0x0B + 4 * slot, then a spare byte, then a u24. Section 20 corrected this document
from a u32 table at 0x0C to a {u8 spare; u24 address} table at 0x0B, on arithmetic over
fifteen samples. Here the firmware computes it. The correction is no longer an inference.
A slot to consumer map, for free¶
Because 0x10B92 takes the slot in a register that callers load with a literal, one scan gives
every consumer. On the Harmony 700 2.8 image, 19 call sites:
| base slot | consumer at | what is known |
|---|---|---|
| 3 | 0x14956, 0x14F9A |
the build timestamp, section 21 |
| 4 | 0x16B98 |
|
| 5 | 0x17EF6 |
the infrared database, section 32. The consumer indexes twice, group then record, which is the two level structure read from the container |
| 6 | 0x16816 |
|
| 7 | 0x1851A |
|
| 8 | 0x0F78A |
key press bindings, section 27 |
| 9 | 0x1B6FE |
|
| 10 | 0x10CC0 |
the action list table, section 34 |
| 11 | 0x1881C |
|
| 12 | 0x174CA, 0x17596 |
|
| 13 | 0x179A4, 0x17E8C |
the state variable table, this section |
| 14 | 0x1B312 |
|
| 15 | 0x0F904 |
|
| 16 | 0x19A90 |
|
| 17 | 0x1A70C, 0x1A788 |
Slots 0, 1 and 2 are absent because they are read by the loader rather than by a subsystem, and slots 18 and 19 are NULL everywhere. Every other slot has a named entry point now, which turns labelling the remaining ten from a search into a reading.
What is not established¶
What the count pointers in slot 13 point at. Ninety four of them on the 700, three bytes each.
Definitions, defaults or names are all plausible and none is checked.
Why the header repeats narrow. Two fields hold the same number in all ten configs.
Narrowed by section 276: on arch 12 (Harmony One) and arch 14 (Harmony 600 and 700) the fourth
word is fetched and nothing stores it, so nothing on those remotes uses it, and on arch 9 (Harmony
525) it is read, section 274. Whether the host software used it is still unknown. That section also
finds the third word is not decoration either: narrow + wide is the bound the firmware checks an
index against, and count is not consulted, so this section's observation that the three add up is a
rail rather than a convention.
What any individual variable means. The table is sized and split; nothing here names entry 9,
which is the one 0x71 reads most. Answered by section 86: base slot 0 names every variable
the generator gave a name to, and the name says what it is for and how many values it takes.