35. Base slot 13 is the state variable table, and the firmware confirms the section table

Section 34 left 0x17E28 as an unnamed lookup that 0x70, 0x71 and 0x72 all index with a byte. Reading it names a section, places a third opcode, and confirms in code the one claim in this project that had to be corrected in place.

What 0x17E28 reads

A table in RAM at 0x0900, with two halves:

index < threshold:   one byte  at 0x0900 + index,               zero extended to sixteen bits
index >= threshold:  two bytes at 0x0900 + threshold + 2 * (index - threshold), little endian

The threshold lives at 0x1EA. So the variables are narrow first, then wide, and how wide a variable is follows from its index rather than from anything stored beside it.

Where the table comes from

The initialiser at 0x17974 positions on config section slot 13 and reads a four field header, storing the second field into 0x1EA. In the container that section is:

+0x00  u16  count           how many variables
+0x02  u16  narrow          how many are one byte, and the firmware's threshold
+0x04  u16  wide            how many are two bytes
+0x06  u16  narrow again    the same number a second time, purpose unestablished
+0x08  u24  entry[count]

Checked on all ten configs: narrow + wide == count, the fourth field always equals the second, and 8 + 3 * count equals the section's length exactly.

config arch count narrow wide RAM it occupies
700 14 94 67 27 121
600 14 74 55 19 93
525 9 24 23 1 25
One, programmed 12 46 45 1 47
One, unprogrammed 12 42 41 1 43
880 c 8 38 37 1 39

"State variables" is one of the four subsystems the format's designer named in harmony-decompiler discussion 1, alongside infrared sending, menus and action lists. Two of those four are now named.

The closure

Every 0x70, 0x71 and 0x72 index in every config is below that config's own count. That is already a fit across ten different counts from 24 to 94. But the split is sharper than that:

opcode uses indices
0x71 2164 always below narrow, so always a one byte variable
0x70 146 always at or above narrow, so always a two byte variable
0x72 501 either half

Zero violations, ten configs, four architectures.

Section 34 read the firmware and found that 0x71 compares a byte variable while 0x70 compares the sixteen bit accumulator. The config data has no way to know that, and it respects the exact boundary that each config's own header declares. Two readings from opposite ends meeting on a number that varies per config, 67 on the 700 and 55 on the 600 and 45 on the One.

In six of the ten configs the largest index used is count - 1, so the last variable is live and the count is a size rather than a ceiling.

Selectors 6 and 7 assign

Section 34 left them as "not comparisons". 0x17D0E reads the variable through the same lookup, adds a sixteen bit delta and clamps against a bound. So 0x70 and 0x71 are one instruction that either tests a state variable or updates it, and the selector nibble chooses.

The section table, confirmed in code

The routine every consumer goes through, 0x10B92, is four instructions of arithmetic:

offset = 4 * slot
offset = offset + 0x0B
seek to the container plus offset
read one byte and discard it
follow the three byte pointer that comes next

That is 0x0B + 4 * slot, then a spare byte, then a u24. Section 20 corrected this document from a u32 table at 0x0C to a {u8 spare; u24 address} table at 0x0B, on arithmetic over fifteen samples. Here the firmware computes it. The correction is no longer an inference.

A slot to consumer map, for free

Because 0x10B92 takes the slot in a register that callers load with a literal, one scan gives every consumer. On the Harmony 700 2.8 image, 19 call sites:

base slot consumer at what is known
3 0x14956, 0x14F9A the build timestamp, section 21
4 0x16B98
5 0x17EF6 the infrared database, section 32. The consumer indexes twice, group then record, which is the two level structure read from the container
6 0x16816
7 0x1851A
8 0x0F78A key press bindings, section 27
9 0x1B6FE
10 0x10CC0 the action list table, section 34
11 0x1881C
12 0x174CA, 0x17596
13 0x179A4, 0x17E8C the state variable table, this section
14 0x1B312
15 0x0F904
16 0x19A90
17 0x1A70C, 0x1A788

Slots 0, 1 and 2 are absent because they are read by the loader rather than by a subsystem, and slots 18 and 19 are NULL everywhere. Every other slot has a named entry point now, which turns labelling the remaining ten from a search into a reading.

What is not established

What the count pointers in slot 13 point at. Ninety four of them on the 700, three bytes each. Definitions, defaults or names are all plausible and none is checked.

Why the header repeats narrow. Two fields hold the same number in all ten configs. Narrowed by section 276: on arch 12 (Harmony One) and arch 14 (Harmony 600 and 700) the fourth word is fetched and nothing stores it, so nothing on those remotes uses it, and on arch 9 (Harmony 525) it is read, section 274. Whether the host software used it is still unknown. That section also finds the third word is not decoration either: narrow + wide is the bound the firmware checks an index against, and count is not consulted, so this section's observation that the three add up is a rail rather than a convention.

What any individual variable means. The table is sized and split; nothing here names entry 9, which is the one 0x71 reads most. Answered by section 86: base slot 0 names every variable the generator gave a name to, and the name says what it is for and how many values it takes.


Section 34 | the archive | section 36. Section 35 of the findings archive, which is frozen; the reference holds the current answer. The archive on GitHub.