Skip to content

387. The Harmony 600 built from nothing runs, and shows no Off screen with the mark it waits for at 1

todo-compile-600.md 1.1 to 1.4: the empty configuration of section 374 built for the Harmony 600, what the 0.2 image says about its colourless panel, and the file written to the bench 600 and run. Checked first: the 0.2 image and this file's own sections; MyHarmony's client holds nothing about turning a picture grey.

The 600 takes the 650's empty configuration. The builder takes skins 71 and 73 and gives them the 650's fourteen firmware screens and their pictures, and the wiring builds the 600 with no activity as it builds the 650, our choice carried over as it was to the Harmony 700, section 382. Built for skin 73 it passes the container checks, the wiring, firmware screen and screen record rebuilds, and the attribution with every byte to a generator and none carried, and differs from the 650's built for skin 72 in three runs of bytes, the middle one the settings block's third group. The menus' leading to each other and the firmware screen counts are asserted on skins 72 and 66 and not here.

The bench unit reports skin 71 and its own compile states 73. The version block read off the remote says 71; h600_config, Logitech's compile of this unit's configuration, says 73, the European 600 of section 131. Base slot 1 is host side on the images section 81 scanned, the Harmony One's, 525's and 700's; the 600's 0.2 image was not scanned. Ours states 73, as Logitech's does, and the skin 71 build has not been run.

The drawing paths read hand the panel every pixel unchanged. On the 0.2 image a picture of either kind, raw or encoded, reaches one row writer, 0x130B6, which sends the controller's row and column address commands and then moves each byte from the external flash's SPI buffer to the panel's, two per pixel in stored order, with no arithmetic between; text glyphs take the encoded body, sections 367 and 370; a filled rectangle, 0x12DA8, sends its two byte colour the same way. A third path, 0x12EB8, expands a one bit pattern into colours the firmware fixes, 0x39E7, 0xFFFF and 0x0000, through that fill. The panel set up, sent at every start, selects sixteen bits per pixel, 3A 05, and in both its variants sends command 0xF9 with a rising table of sixteen entries, 00 02 to 1C and 00 03 to 1F, which reads as the controller's grey scale or timing table, not confirmed. The row writer is byte for byte the Harmony 650's 0.2 code at the same address, and the set up and the panel's byte sender are identical but for four bytes, each the address of a routine or table that sits 12 bytes lower on the 650. What a colour becomes on the glass is decided in the display module on the paths read, and the image cannot say whether it is one bit or has grey levels, or which channels count. The set up reads the controller's first identity byte into data memory 0x384 and takes its first variant where it is 1; read over USB on the bench 600, on the cable, it is 0 (reads/20261014T1445Z-h600-ram-384-panel-id.txt), so the 600 takes the variant other than the one for 1, as the 650 does with its 0. Logitech's pictures for the 600 are all grey, within one step on every pixel of calibration_h600 and h600_config, and use the full depth of shades: evidence of what their artists drew for, not of the panel.

On the remote: written 14 October 2026, six 64 KiB blocks, read back byte for byte identical, restarted by the writer, and run with 600-empty.json, seven steps over 113 s. No frame was recorded, as predicted for a configuration with no device; nothing in the run shows the receiver was listening. The session marks a step reached when it is opened, so the run holds four notes and no other observation: "no turning off message again" on the first step, "no anti-aliasing anywhere" on the second, "no tunring off message" on All Off, and "20s" on the screen light. How our look showed on this panel, which the first step asked, and what More Activities showed were not recorded; the test predicted More Activities as it behaved before section 383, and the file binds it to "add Activities".

"Turning system off" did not show, and the mark it waits for read 1. Not when the cable came out and not on All Off. This unit's variables are readable live on the cable, as section 303 read its delays: the state variables sit from 0xE10, the clock in variables 0 to 6 read 16:44:58 and then 16:45:18 on Wednesday 14 October 2026, so it is running, and variable 24, the mark, read 1 at 0xE28 (reads/20261014T1445Z-h600-ram-e00-empty-on.txt). Section 110's journal reading does not say otherwise: it measured five variables of another kind. So on the 600 the mark at 1 is not enough, and a seeding left at a previous configuration's 0 is ruled out. Set beside the other runs of a file of ours:

run mark in the file Off seen
Harmony 650, empty, section 374 0 on All Off; leaving the cable not reported
Harmony 700, empty, section 383 0 leaving the cable and All Off
Harmony 700, test setup, section 386 0, read 0 not on All Off
Harmony 700, test setup, section 386 1, read 1 on All Off
Harmony 600, empty 1, read 1 neither

The control: the same file with the mark at 0 shows no Off either. empty-600-73-markoff.bin is the written file with the mark's first set to 0, one byte and the checksum, written over two blocks, read back byte for byte, and after the write's restart 0xE28 read 0 (reads/20261014T1510Z-h600-ram-e00-markoff-on.txt). Run with 600-empty-mark-off.json: "doesn't show" when the cable came out, and on All Off, pressed three times, "nothing happens". So on the 600 neither value of the mark brings the screen, and the mark is not what tells this run from the 650's.

The two empty files showed Off with the mark at 0, so on those the mark is not what gates it either, and section 386's reading of the All Off path covers the test setup and not the empty configuration; the cable path is section 382's leave handler, not traced. The empty 650 and the empty 600 run the same 0.2 build on files that differ in the skin, the settings block's third group and the mark. That the screen is drawn and is too brief for this panel to show is one reading, not measured.

The panel shows a colour as a grey of its own. On the control run the Activities screen's background, our idle colour 0x0446, a green of about (0, 138, 49), was seen as "gray but not very dark", the bars at top and bottom with good contrast against it, and the background wanted "a lot darker". So the panel is not one bit: this colour lands on a shade between black and white. How many shades there are, and which channels count, is not measured.

The one look, in grey 2. Every state of a configuration of ours for the 600 is drawn in one look, decided on 14 October 2026: ONE_LOOK_SKINS, under which ourStateColours reads the device and activity states as the idle one, so a composer adds no look of its own and recolouredStates takes one colour. Its grey is oneLookColour, 0x2104, grey 2 of sixteen steps from black to white, picked off the preview of a test card (lab/work/h600-from-nothing/ramp.ts) that was not itself written; Logitech's 600 compiles use the same value among their greys. Written to the bench 600 in the empty configuration, three blocks, the first run stopped by a chunk out of sequence while a test suite ran and the rerun with the same arguments completed and read back byte for byte; on the remote the greys were judged good.

The letters showed no smoothing, which is what the file held: smoothing is the blending of a letter's edge into the colour under it, section 370, and the 600 was built without it until its panel was known, so its letters were drawn in their ink and shadow alone. That run said nothing about grey levels.

The letters blended into grey 2, kept. With the panel seen to show a colour as a grey of its own, the 600's skins joined BLENDED_LETTER_SKINS on 14 October 2026. The empty configuration in grey 2 with its letters blended, six blocks, read back byte for byte, was judged on the remote against the same file unblended and the blended letters looked better; kept. The firmware screen and screen record rebuilds fail on a blended file by design, the blending being the last step, as on the 650 and 700.

The settings store holds one saved delay, an inter device delay of 15 tenths for key 0x0E26 (reads/20261014T1445Z-h600-settings-empty-on.txt), which a configuration with no device does not use.

Scope, decision 16

One Harmony 600, build 0.2, which reports skin 71, running our file stating 73. The display path reading covers the 600's and the 650's 0.2 images; the 700's 2.8 keeps both set up variants and adds two more, not read further.

Falsification

A pixel path on the 0.2 image that transforms a colour before the panel's SPI buffer; a 600 bench run on our empty configuration that shows "Turning system off"; a read of 0xE28 after a write's restart that is not the file's first; a 600 that shows 0x0446 as black or as white.

Where it lands

  • packages/codec/src/families/four-slot/empty.ts: skins 71 and 73; packages/codec/src/families/four-slot/wiring.ts: no activity on the 600; packages/codec/src/backgrounds.ts: the 600's skins in our look, in one look and blended; packages/codec/src/families/four-slot/choices.ts: oneLookColour.
  • packages/codec/test/empty.test.ts: the 600 built from nothing, and the mark at 1 on the built file.
  • packages/bench/irtests/done/600-empty.json and 600-empty-mark-off.json, the tests; their runs and the reads are in the lab's reads/.

Section 386 | the archive | section 388. Section 387 of the findings archive, which is frozen; the reference holds the current answer. The archive on GitHub.