98. The learn samples are never sent: the endpoint is pointed straight at them

Section 91 established the learn session's bracket from the firmware and then failed to find any code that sends capture data. It searched twice, for a routine emitting 0x90 and for a second caller of the byte sender, and found neither, and recorded that "an assumption is wrong" without saying which. This is which: the samples do not go through the byte sender at all. The firmware fills a buffer and hands the USB endpoint that buffer's address, so nothing ever "sends" the bytes one at a time and no code emits 0x90 in the sense the search was looking for.

What 0x40C actually is, which is where the misreading started

0x40C had been read as a response descriptor and 0x40D as a length counter. They are the buffer descriptor for endpoint 1 IN, in the USB dual port RAM that starts at 0x400 on all three parts:

0x40C status. Bit 7 is UOWN, which is why BTFSC 0x40c,7 at 0x2014E means "the previous report has not gone yet"
0x40D byte count, which is why the sender increments it once per byte
0x40E, 0x40F the buffer's address

The proof is 0x2017A, which sets the count to 0x40 and the address to 0x0468 with two literals, in that order, immediately after clearing the write pointer. So the "response buffer" is the endpoint's buffer and the "sender" is a routine that stores a byte into it and bumps the hardware count. Section 96 is unaffected: an unbounded store through a climbing pointer is exactly as bad either way, and rather worse when the pointer starts inside dual port RAM.

This also withdraws a claim of my own from an hour earlier, that three architectures sharing 0x40D says something about the codebase. It says something about the part.

A second producer, pointing the endpoint somewhere else

0x40D and 0x40E have one other writer, at 0x2028C, and it does not use the 0x0468 buffer at all:

2026c: MOVFF 0xd67,FSR0L        ; the buffer chosen below
20274: MOVLW 0x02 / ADDWF       ; skip its two byte header
2027c: MOVLW 0x3f / ADDWF       ; and its 64th payload byte
20284: MOVFF 0xd6b,INDF0        ;   holds the length
2028a: MOVLW 0x40 / MOVWF 0x40d ; a full report
2028e: MOVFF 0xd67,FSR0L        ; and the endpoint reads straight from the buffer + 2
2029e: MOVFF FSR0L,0x40e
202a2: MOVFF FSR0H,0x40f

0xD67 is chosen at 0x201A8 from two buffers at 0x0600 and 0x0642, by a toggle at 0x0684 and a status byte at the head of each. That is a ping pong pair, and the arm happens whenever one is ready rather than in response to anything.

The buffers are the learn session's, and START_IRCAP says so

0x26556 is START_IRCAP, the 0x70 handler. After setting the state to 5 it does exactly one other thing:

2655e: CLRF 0x600     ; buffer A status
26562: CLRF 0x601     ;   and its length
26566: CLRF 0x642     ; buffer B
2656a: CLRF 0x643
2656e: MOVLW 0x01 / MOVWF 0x684   ; and the toggle

The arch 14 handler is the same handler, 0x0C2B2 on the 700, clearing the same four addresses and setting the same toggle, and its transport picks a buffer at 0x16E5E exactly as arch 12's does at 0x201B0. So the mechanism is two architectures, not one.

The report layout, arch 12

The producer is 0x2B68E, called from fourteen sites in the capture path. It appends to whichever buffer is open, opening one with a header when the length is zero:

offset in the buffer
+0 status: 1 while filling, 3 once handed to the endpoint
+1 payload length so far, which starts at 4 and grows by 2
+2 0x90, the response code section 91 went looking for
+3 a sequence byte, 0x28C, which the same routine advances by 0x10 per report
+4 onward samples

and what the host sees is the 64 bytes from +2, zero filled beyond the payload, with the payload length repeated in the last byte of the report. A buffer is closed once its length would pass 0x3D, 61, and the other one takes over.

A sample is a big endian u16, high byte first, appended two bytes at a time. The values are differences of the CCP2 capture register, 0x2B644 onward subtracting one capture from the previous with SUBWF and SUBWFB, so they are durations, not timestamps. The capture path also pushes literal 0x8000 and 0x0000 values as frame markers, and 0x8000 has bit 15 set, which is the same mark bit an infrared duration block uses in a stored config, section 32. So the learn stream and the config's own duration encoding agree, which is the closure worth having: what comes off the remote is already in the form a record wants.

The arch 14 header is the same, and the reason it looked otherwise is a lesson

This section first said the header was arch 12 only, on the strength of a scan finding no store of 0x90 into 0x602 in the 700 or 600 images. That scan was right and the conclusion was wrong. Arch 14 reaches the same buffers through FSR, so the store is MOVWF INDF0, and the scan had in fact reported it, at 0x0938C with f=0xEF. 0xEF is INDF0. It was filtered out by a test for the literal buffer offsets, which is the project's own recorded pitfall about indirect access, made while writing the paragraph that warns about it.

Read properly, the producer at 0x0926E is the same routine:

One 3.4 700 2.8
gate state 5 state 5, 0xEC9
buffers 0x0600 and 0x0642, chosen on 0x0684 the same three addresses
status while filling 1, at +0 1, at +0, 0x0937C
response code at +2 0x90, 0x2B742 0x90, 0x0938C
sequence at +3 0x28C, advanced by 0x10 0xED4, advanced by 0x10
a sample high byte then low byte, length += 2 the same, 0x093C4 and 0x093D0
close a buffer at length past 0x3D length past 0x3D, 0x0932E

So the report layout is two architectures, not one. What is arch 12 only is the differencing: 0x2B644 subtracts one capture from the previous with SUBWF and SUBWFB. On arch 14 the capture reaches the staging variable at 0x091CA with a previous value kept beside it at 0x319, which is the shape of a difference, but the arithmetic itself was not read and 0x090AC is a re-arm of CCP2CON rather than the subtraction. Called a duration on arch 12 and left open on arch 14.

What it settles about the two clients

Section 91 recorded a disagreement it could not resolve: the classic client takes learn reports off a queue a reader thread has already filled, which reads as the remote pushing them unsolicited, while the Desktop client models them as a command's response stream. The firmware sides with the classic client. Nothing in the arming path consults a command: the transport looks at the toggle and the two status bytes on every pass, and hands the endpoint whichever buffer is full. A host that waits for a request to answer will lose reports, and one that keeps reading during the session will not.

That is a requirement for FreeHarmony rather than a curiosity, and it is the half of learning the dead service cannot take with it: the remote produces the timings, and section 92's carrier plus packages/codec's record builder already turn timings into a record.


Section 97 | the archive | section 99. Section 98 of the findings archive, which is frozen; the reference holds the current answer. The archive on GitHub.