70. Opcode 0x7C is a per device quantity, capped at 100 and spelled out above it¶
0x7C is the most used instruction in the corpus, 21882 of 97537, and it has been unread since
section 29 guessed it was "a quantity of at most 100". It is the companion of 0x7D, the infrared
send, and the two differ in one bit.
The handlers are the same routine twice¶
On the Harmony 700 image, 0x7D's handler is 0x130E0 and 0x7C's is 0x13102, sixteen
instructions apart:
130e0: MOVFF 0x09B,0x099 the operand's low byte
MOVFF 0x09A,0x098 its high byte
RCALL 0x12FD6 the worker
... priority 2
13102: BSF 0x09C,6 set bit 6 of the high byte
MOVFF 0x09D,0x099
MOVFF 0x09C,0x098
RCALL 0x12FD6 the same worker
... priority 1
The byte order matters and is settled by the executor: 0x09A and 0x09C are written from 0x1BC,
the popped instruction's second operand byte, so they hold the high byte. That is what
config-format.md's 0x09A/0x09B notation meant and it was ambiguous.
The Harmony One image mirrors it exactly: 0x26F74 with priority 2, 0x26F96 with BSF 0x6BD,6
and priority 1, sharing the worker at 0x26F4E. Two architectures, the same pair of routines.
The worker is a queue, and bit 6 changes what enqueueing means¶
0x12FD6 writes into a circular buffer of 30 bytes at RAM 0x65 to 0x83, with a write cursor at
0x085/0x086, a read cursor at 0x083/0x084 and a count at 0x064. Entries are two bytes,
{ u8 tag; u8 value }, and the tag is kind << 4 | group: 0x0 for a send, 0x4 for this
opcode, and 0x5 for ~~a third producer that is not an action list opcode~~ opcode 0x67,
which section 71 found in the dispatcher: it is one after all.
With bit 6 clear the worker pushes the two bytes and returns. With it set it first walks the queue
to its last entry and then, at 0x13088:
| condition | what happens |
|---|---|
| the last entry's tag differs | push a new entry |
| the last entry's value is already 100 | push a new entry |
| the new value is smaller | drop it |
| otherwise | overwrite the last entry's value |
So consecutive quantities for one device collapse to the larger, except at 100, where the fold is refused and a second entry is pushed instead. That is the mechanism that makes a quantity above 100 expressible at all, and it is read off the code rather than inferred from the data.
The sender consults the queue for a 0x4 tag at 0x13830 and 0x13AC8, through the scan at
0x13204, and changes its own timing parameter accordingly.
The corpus closes it twice¶
The group is always one the infrared table has. Over 21882 uses in twelve containers spanning
four architectures, every high byte is below that config's infrared group count, with no exception.
That is the closure section 33 used for 0x7D, applied to a table this operand was not derived
from, and the group counts vary from 1 to 7 across the corpus so it is not vacuous.
~~The value never exceeds the cap. 0 to 100 everywhere, never 101, in all 21882.~~ True of the twelve
containers counted and not of Logitech's compiler, section 327: the spare Harmony One's compile of a hand
authored sequence holds twelve 0x7C of 200, a 20 second wait written as one instruction per device.
And arch 14 spells the whole range out. Its configs carry a generated table of lists made of
nothing but this opcode, (g,100) repeated then a remainder:
| container | groups | lists per group | totals |
|---|---|---|---|
| Harmony 700, both configs | 6 | 350 | 101 to 450, contiguous |
| Harmony 600 | 4 | 350 | 101 to 450, contiguous |
Every total from 101 to 450, once per group, nothing missing and nothing twice, and not one list
of the 4900 fails the cap-then-remainder shape. A reading where the run did not sum would have to
explain why the last instruction's value is exactly total - 100 * (length - 1) in every one of
them.
The table starts at 101 because 1 to 100 needs a single instruction and is not worth a list of its
own. Arch 8, 9 and 12 have no such table: there 0x7C almost always follows a 0x7D for the same
group, 340 of 345 on a Harmony One, carrying a small value.
What is not established¶
~~What the quantity measures. The evidence says it is per device, bounded at 450 in practice, consumed by the infrared sender, and folded by taking the larger of two consecutive requests. That last rule is what a duration behaves like and not what a repeat count behaves like, but the unit is a guess and this document does not make it. Finishing it wants the timer that drains the queue.~~
It is a delay, in tenths of a second, section 235. The instinct above was right and the reason given for not finishing it was wrong: what settled it was not the timer that drains the queue but a pair of configurations Logitech compiled for the same three devices, one for a Harmony One and one for a Harmony 600. Arch 14 states a device's power on delay in a state variable whose unit its own screen spells out in tenths of a second; arch 8, 9 and 12 state it as one of these instructions in the list that switches the device on. The two agree device for device, so the operand is tenths of a second, and the 450 ceiling is 45 seconds. The fold rule reads correctly under it: two requests for one device collapse to the longer wait.
~~The third producer, tag 0x5, which reaches the same worker from outside the action list
language.~~ It is opcode 0x67, section 71, and it was called an outsider only because this
section read the queue before the dispatcher. What it means is still open.
The rails it yields¶
- ~~The value is capped at 100 by the firmware, not by convention. A writer emitting 150 in one
instruction gets a queue entry the sender will treat as 150 only if nothing folds it, and the
fold rule is written against the cap. Spell it out.~~ The firmware refuses to fold past 100 and does
not cap a single entry, which is all the code above shows, and Logitech's compiler writes a sequence's
20 second wait on the Harmony One as one
0x7Cof 200, section 327. Whether the remote then waits the whole 20 seconds is unmeasured. No inline power on delay on arch 8, 9 or 12 exceeds 100, arch 14 spells 101 to 450 out in its tables, andsetPowerOnDelaystill refuses past 100. - A config cannot have more than sixteen infrared groups, because the queue tag is
kind << 4 | group. The corpus tops out at seven, so nothing has met this, and a generator that did would corrupt the tag rather than fail. - Consecutive quantities for one device are not independent. An editor inserting one next to an existing one changes the existing one's effect.
Where it lands¶
docs/config-format.md, the action list opcode inventory:0x7Cmoves out of the unread table.packages/codec/src/ir.ts:irQuantitywithIR_QUANTITY_OPCODE,IR_QUANTITY_CAP,IR_QUANTITY_QUEUE_BITandIR_MAX_GROUPS.packages/codec/test/sections.test.ts: the group closure against the infrared table, the 101 to 450 closure, and the refusals that stopirQuantitysumming a shape it has not read.
Section 69 | the archive | section 71. Section 70 of the findings archive, which is frozen; the reference holds the current answer. The archive on GitHub.