71. The 0x65 to 0x6D block is an accumulator machine, and 0x6C writes a device record

Section 70 read one opcode by chasing its handler. This reads the dispatcher instead and takes nine at once, which is the cheaper move and should have come first: the binary search at 0x0EC8E on the Harmony 700 image names a handler for every opcode in 0x65 to 0x7F, so each is a routine to read rather than a thing to look for.

The accumulator machine

Sections 34 and 39 placed 0x7A as "load the accumulator", 0x79 as "add", and 0x78 and 0x77 as two more operations through helpers. The block below 0x6E is the rest of the same machine, working on the sixteen bit pair at RAM 0x10E/0x10F:

opcode handler what it does
0x6D 0x0F052 accumulator shifted left by the operand's low byte, RLCF in a loop
0x6C 0x0F072 writes a device record, below
0x6B 0x0F096 accumulator AND operand
0x6A 0x0F0BA accumulator OR operand
0x69 0x0F0DE accumulator XOR operand
0x68 0x0F104 accumulator shifted right by the operand's low byte, RRCF in a loop
0x67 0x0F12C operand to 0x09E/0x09F, then 0x13128
0x66, 0x65 0x0F146 the operand's high byte, or both bytes, to 0x159F4

Both shifts read their count from WREG and skip the loop entirely when it is zero, so a shift of zero is a defined no-op rather than a shift of 256.

0x67 closes an open item in section 70. That section found a third producer feeding the infrared queue with tag 0x5 and said it was not an action list opcode. It is: 0x67, and the routine it calls is 0x13128, the third of the three siblings section 70 disassembled. Reading the queue before the dispatcher is what made it look like an outsider.

And 0x74 and 0x75 are the same instruction. The dispatcher never compares against 0x75: at 0x0EE12 it tests >= 0x74 and both fall into one handler, and nothing downstream reads the opcode byte 0x1BD, whose only readers are the two dispatcher comparisons themselves. So 0x75's 4380 uses run 0x74's code. What that code means is still open; that there is one meaning and not two is not.

0x6C never stands alone

Every use in the corpus is the second half of a pair:

0x7A key        load the accumulator
0x6C value      write it

7552 of 7552, in three arch 14 containers, and the list holding them is exactly those two instructions and nothing else, 2832, 2832 and 1888 times. Arch 8, 9 and 12 do not use the opcode at all.

The handler passes the operand to 0x11B92, which splits bit 15 off into its own argument, clears it, looks the accumulator up to a record index with 0xFF for not found, and writes the remaining fifteen bits as two bytes into that record. So the operand is a field selector and a value, not one number.

The corpus says the key is a device

container infrared groups distinct 0x7A keys
Harmony 700, both configs 6 6
Harmony 600 4 4

And per key, exactly:

field values count
bit 15 clear 0 to 450, contiguous 451
bit 15 set 0 to 20, contiguous 21

Every key, every container, with nothing missing and nothing twice. 6 times 472 is 2832 and 4 times 472 is 1888, which is every use accounted for. A reading where bit 15 were part of the value would have to explain why 0 to 450 and 0x8000 to 0x8014 are both complete and nothing lies between.

0 to 450 is the same enumeration 0x7C carries, section 70, reached from an unrelated direction: there it is a per group quantity spelled in units of at most 100, here it is one instruction per value. So the two opcodes write the same kind of thing by different routes, and the 0x7C route exists because a byte wide queue cannot carry 450.

The keys are 16 bit values that occur nowhere else in the container except as 0x7A operands, so they are identifiers the generator brought in rather than offsets into anything here. On the 700 three of the six share a high byte, 0x1E04, 0x1E06 and 0x1E07, which is what a run of device ids from one manufacturer looks like. That is a suggestion and not a reading.

The generated tables

The 0x7C lists of section 70 sit in contiguous blocks of 350 table entries, one block per group, though not in ascending order of total. The [0x7A, 0x6C] lists are scattered through the table instead. Both are generated sets covering a range exhaustively, which is what a settings menu needs: one action list per selectable value.

What it moves

Of 97537 action list instructions in the corpus, the share using an opcode with a reading goes from 64.6% to 72.3%. What is left at the top is 0x1F at 6119 uses, 0x07 at 5739, 0x75 and 0x74 at 4380 and below, 0x73 at 3927 and 0x00 at 3053.

Where it lands

  • docs/config-format.md, the action list opcode table.
  • packages/codec/src/ir.ts: deviceAssignment, ACCUMULATOR_LOAD_OPCODE, DEVICE_ASSIGN_OPCODE and DEVICE_ASSIGN_FIELD_BIT.
  • packages/codec/test/sections.test.ts: that no 0x6C stands alone, the key count against the infrared table, both fields enumerated exhaustively, and the pair's refusals.